Efficacy and validity of automated quantitative chemiluminescent enzyme immunoassay for SARS-CoV-2 antigen test from saliva specimen in the diagnosis of COVID-19. Issue 7 (July 2021)
- Record Type:
- Journal Article
- Title:
- Efficacy and validity of automated quantitative chemiluminescent enzyme immunoassay for SARS-CoV-2 antigen test from saliva specimen in the diagnosis of COVID-19. Issue 7 (July 2021)
- Main Title:
- Efficacy and validity of automated quantitative chemiluminescent enzyme immunoassay for SARS-CoV-2 antigen test from saliva specimen in the diagnosis of COVID-19
- Authors:
- Asai, Nobuhiro
Sakanashi, Daisuke
Ohashi, Wataru
Nakamura, Akiko
Kawamoto, Yuzuka
Miyazaki, Narimi
Ohno, Tomoko
Yamada, Atsuko
Chida, Sumie
Shibata, Yuichi
Kato, Hideo
Shiota, Arufumi
Hagihara, Mao
Koita, Isao
Yamagishi, Yuka
Suematsu, Hiroyuki
Ohta, Hirotoshi
Mikamo, Hiroshige - Abstract:
- Abstract: Introduction: The pandemic of a novel coronavirus disease 2019 (COVID-19) caused by a severe acute respiratory coronavirus 2 (SARS-CoV-2) infection has been problematic worldwide. A new SARS-CoV-2 antigen test (LUMIPULSE Ⓡ ) was licensed and widely used in Japan since May 2020. We conducted this study intending to whether the automated quantitative CLEIA antigen test using a saliva sample is effective and valid for the diagnosis of COVID-19. Patients and methods: We analyzed and compared the diagnostic accuracy of both the automated quantitative CLEIA antigen test and real-time RT-PCR (rRT-PCR) using a saliva sample from individuals suspected as having COVID-19. Results: A total of 305 samples were collected and tested in Aichi Medical University Hospital and affiliated facilities from December 2020 until January 2021 at our institute. Using reverse-transcription PCR as a reference, the AUROC of the automated quantitative CLEIA antigen test was 0.903 (95% confidential interval 0.845–0.962, p < 0.001). The appropriate cut-off antigen level was 4.0 pg/mL and had a sensitivity of 77.8%, a specificity of 99.6%, a positive predictive value of 98%, and a negative predictive value of 94.5%. On the other hand, the diagnostic accuracy of the antigen test decreased among patients among patients with COVID-19 with threshold cycle (Ct-value)≥27, which shows the AUROC was 0.795 (95%CI 0.687–0.907, p < 0.001). Conclusion: While the automated quantitative CLEIA antigen testAbstract: Introduction: The pandemic of a novel coronavirus disease 2019 (COVID-19) caused by a severe acute respiratory coronavirus 2 (SARS-CoV-2) infection has been problematic worldwide. A new SARS-CoV-2 antigen test (LUMIPULSE Ⓡ ) was licensed and widely used in Japan since May 2020. We conducted this study intending to whether the automated quantitative CLEIA antigen test using a saliva sample is effective and valid for the diagnosis of COVID-19. Patients and methods: We analyzed and compared the diagnostic accuracy of both the automated quantitative CLEIA antigen test and real-time RT-PCR (rRT-PCR) using a saliva sample from individuals suspected as having COVID-19. Results: A total of 305 samples were collected and tested in Aichi Medical University Hospital and affiliated facilities from December 2020 until January 2021 at our institute. Using reverse-transcription PCR as a reference, the AUROC of the automated quantitative CLEIA antigen test was 0.903 (95% confidential interval 0.845–0.962, p < 0.001). The appropriate cut-off antigen level was 4.0 pg/mL and had a sensitivity of 77.8%, a specificity of 99.6%, a positive predictive value of 98%, and a negative predictive value of 94.5%. On the other hand, the diagnostic accuracy of the antigen test decreased among patients among patients with COVID-19 with threshold cycle (Ct-value)≥27, which shows the AUROC was 0.795 (95%CI 0.687–0.907, p < 0.001). Conclusion: While the automated quantitative CLEIA antigen test from saliva specimen could be one of the most useful diagnostic tests for the diagnosis of COVID-19 in general practice, clinicians should know the limitations of the antigen test. … (more)
- Is Part Of:
- Journal of infection and chemotherapy. Volume 27:Issue 7(2021)
- Journal:
- Journal of infection and chemotherapy
- Issue:
- Volume 27:Issue 7(2021)
- Issue Display:
- Volume 27, Issue 7 (2021)
- Year:
- 2021
- Volume:
- 27
- Issue:
- 7
- Issue Sort Value:
- 2021-0027-0007-0000
- Page Start:
- 1039
- Page End:
- 1042
- Publication Date:
- 2021-07
- Subjects:
- SARS-CoV-2 -- Saliva -- Quantitative chemiluminescent enzyme immunoassay -- RT-PCR -- COVID-19
Chemotherapy -- Periodicals
Infection -- Periodicals
Communicable diseases -- Chemotherapy -- Periodicals
615.5805 - Journal URLs:
- http://www.sciencedirect.com/science/journal/1341321X ↗
http://link.springer-ny.com/link/service/journals/10156/index.htm ↗
http://www.springerlink.com/content/1341-321x ↗
http://www.elsevier.com/journals ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1016/j.jiac.2021.03.021 ↗
- Languages:
- English
- ISSNs:
- 1341-321X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5006.691000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18238.xml