Shear performance and dimension rationalization study on the rubber sleeved stud connector in continuous composite girder. (1st August 2021)
- Record Type:
- Journal Article
- Title:
- Shear performance and dimension rationalization study on the rubber sleeved stud connector in continuous composite girder. (1st August 2021)
- Main Title:
- Shear performance and dimension rationalization study on the rubber sleeved stud connector in continuous composite girder
- Authors:
- Su, Hang
Su, Qingtian
Xu, Chen
Zhang, Xieli
Lei, Dongyang - Abstract:
- Highlights: Fifteen push-out tests concerning with rubber sleeved studs were conducted. The parametric push-out FEM analysis was conducted as well. The stud wrapped by rubber had obviously lower stiffness while the strength changed little. The rational size of rubber sleeve for stiffness degradation was obtained by parametric analysis. The rubber sleeved studs could reduce concrete tensile stress in the hogging moment region. Abstract: Wrapping rubber sleeve around a stud shank near the root makes a low level of shear connection between the steel girder and concrete slab in a composite girder. It helps to reduce the concrete tensile stress and steel compressive stress in the hogging moment region. However, the specific mechanical effects of the rubber dimension and modulus on the connector performance have not been understood, which hinders the application in practice. To this end, 15 push-out tests on studs wrapped with rubber sleeves were conducted for the investigation. And a push-out parametric analysis with damage plasticity models was executed for dimension rationalization. The test results showed an obviously lower stiffness and larger bending deformation of rubber-sleeved stud as compared with a normal stud, while the strength varied little. The analysis results showed that the efficient rubber thickness and length for a 22 mm-diameter and 220 mm-high stud could be 4 mm and 50 mm in terms of the stiffness reduction extent. It also showed an obvious stiffnessHighlights: Fifteen push-out tests concerning with rubber sleeved studs were conducted. The parametric push-out FEM analysis was conducted as well. The stud wrapped by rubber had obviously lower stiffness while the strength changed little. The rational size of rubber sleeve for stiffness degradation was obtained by parametric analysis. The rubber sleeved studs could reduce concrete tensile stress in the hogging moment region. Abstract: Wrapping rubber sleeve around a stud shank near the root makes a low level of shear connection between the steel girder and concrete slab in a composite girder. It helps to reduce the concrete tensile stress and steel compressive stress in the hogging moment region. However, the specific mechanical effects of the rubber dimension and modulus on the connector performance have not been understood, which hinders the application in practice. To this end, 15 push-out tests on studs wrapped with rubber sleeves were conducted for the investigation. And a push-out parametric analysis with damage plasticity models was executed for dimension rationalization. The test results showed an obviously lower stiffness and larger bending deformation of rubber-sleeved stud as compared with a normal stud, while the strength varied little. The analysis results showed that the efficient rubber thickness and length for a 22 mm-diameter and 220 mm-high stud could be 4 mm and 50 mm in terms of the stiffness reduction extent. It also showed an obvious stiffness reduction occurred when the wrapping material modulus was 10% lower than concrete. Furthermore, the connector stiffness effect on the stress distribution along with a continuous composite girder was analyzed and quantified, showing a 39% reduction of concrete slab stress in the hogging moment region and a 13% increase of steel stress on the top flange. … (more)
- Is Part Of:
- Engineering structures. Volume 240(2021)
- Journal:
- Engineering structures
- Issue:
- Volume 240(2021)
- Issue Display:
- Volume 240, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 240
- Issue:
- 2021
- Issue Sort Value:
- 2021-0240-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-08-01
- Subjects:
- Steel-concrete composite structure -- Push-out test -- Numerical study -- Stud connector -- Rubber sleeve -- Composite mechanism
Structural engineering -- Periodicals
Structural analysis (Engineering) -- Periodicals
Construction, Technique de la -- Périodiques
Génie parasismique -- Périodiques
Pression du vent -- Périodiques
Earthquake engineering
Structural engineering
Wind-pressure
Periodicals
624.105 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01410296 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.engstruct.2021.112371 ↗
- Languages:
- English
- ISSNs:
- 0141-0296
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3770.032000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18239.xml