Six-Minute Walk Test in Individuals With Unilateral Lower Limb Amputations. Issue 4 (28th October 2021)
- Record Type:
- Journal Article
- Title:
- Six-Minute Walk Test in Individuals With Unilateral Lower Limb Amputations. Issue 4 (28th October 2021)
- Main Title:
- Six-Minute Walk Test in Individuals With Unilateral Lower Limb Amputations
- Authors:
- Younesian, Hananeh
Ouellet, Raphaël
Legrand, Thomas
Turcot, Katia - Abstract:
- Background: The 6-minute walk test (6MWT) is one of the common clinical tests to assess rehabilitation progress and needs in individuals with lower-limb amputation (iLLAs). However, the analysis of this test is mostly limited to the distance parameter. The first aim was to investigate effort intensity and spatiotemporal parameters of 6MWT in iLLAs using inertial measurement units (IMUs) and heart rate (HR) monitor, and second, to assess physical, physiological, and pain-related aspects of fatigue over 6MWT. Methods: Eleven unilateral iLLAs (57.91±15.63 years old) participated in this study. To evaluate HR and spatiotemporal parameters over 6MWT, data were classified using 6 intervals of 1 minute each (I1-I6). The pain level of participants was estimated using the visual analog scale (VAS). Results: Our results showed that the means of normalized HR gradually increased over 6MWT (I1: 61.59±10.73 HRmax %, I6: 70.15±12.26 HRmax %, P = .003). Variability of HR during the first interval of 6MWT was higher than the others ( P < .05). The stance ratio of the gait cycle increased over 6MWT ( P < .05). Cadence and speed decreased over 6MWT ( P < .05). VAS score after 6MWT was significantly higher than before 6MWT ( P = .016). Conclusion: In this preliminary study, effort intensity over 6MWT gradually increased because of enhancement of HR. Deterioration of speed and cadence and enhancement of stance ratio over 6MWT imply potential physical aspects of fatigue and instability. Level ofBackground: The 6-minute walk test (6MWT) is one of the common clinical tests to assess rehabilitation progress and needs in individuals with lower-limb amputation (iLLAs). However, the analysis of this test is mostly limited to the distance parameter. The first aim was to investigate effort intensity and spatiotemporal parameters of 6MWT in iLLAs using inertial measurement units (IMUs) and heart rate (HR) monitor, and second, to assess physical, physiological, and pain-related aspects of fatigue over 6MWT. Methods: Eleven unilateral iLLAs (57.91±15.63 years old) participated in this study. To evaluate HR and spatiotemporal parameters over 6MWT, data were classified using 6 intervals of 1 minute each (I1-I6). The pain level of participants was estimated using the visual analog scale (VAS). Results: Our results showed that the means of normalized HR gradually increased over 6MWT (I1: 61.59±10.73 HRmax %, I6: 70.15±12.26 HRmax %, P = .003). Variability of HR during the first interval of 6MWT was higher than the others ( P < .05). The stance ratio of the gait cycle increased over 6MWT ( P < .05). Cadence and speed decreased over 6MWT ( P < .05). VAS score after 6MWT was significantly higher than before 6MWT ( P = .016). Conclusion: In this preliminary study, effort intensity over 6MWT gradually increased because of enhancement of HR. Deterioration of speed and cadence and enhancement of stance ratio over 6MWT imply potential physical aspects of fatigue and instability. Level of Evidence: Level III, retrospective comparative study. … (more)
- Is Part Of:
- Foot & ankle orthopaedics. Volume 6:Issue 4(2021)
- Journal:
- Foot & ankle orthopaedics
- Issue:
- Volume 6:Issue 4(2021)
- Issue Display:
- Volume 6, Issue 4 (2021)
- Year:
- 2021
- Volume:
- 6
- Issue:
- 4
- Issue Sort Value:
- 2021-0006-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-10-28
- Subjects:
- lower limb amputation -- inertial measurement units -- heart rate -- 6-minute walk test
Foot -- Surgery -- Periodicals
Ankle -- Surgery -- Periodicals
Orthopedics -- Periodicals
617.584 - Journal URLs:
- http://www.sagepublications.com/ ↗
http://journals.sagepub.com/toc/faoa/current ↗ - DOI:
- 10.1177/24730114211050366 ↗
- Languages:
- English
- ISSNs:
- 2473-0114
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18255.xml