Diagnostic performance of digital breast tomosynthesis for predicting response to neoadjuvant systemic therapy in breast cancer patients: A comparison with magnetic resonance imaging, ultrasound, and full-field digital mammography. (3rd December 2021)
- Record Type:
- Journal Article
- Title:
- Diagnostic performance of digital breast tomosynthesis for predicting response to neoadjuvant systemic therapy in breast cancer patients: A comparison with magnetic resonance imaging, ultrasound, and full-field digital mammography. (3rd December 2021)
- Main Title:
- Diagnostic performance of digital breast tomosynthesis for predicting response to neoadjuvant systemic therapy in breast cancer patients: A comparison with magnetic resonance imaging, ultrasound, and full-field digital mammography
- Authors:
- Murakami, Ryusuke
Tani, Hitomi
Kumita, Shinichiro
Uchiyama, Nachiko - Abstract:
- Background: The goals of neoadjuvant systemic therapy (NST) are to reduce tumor volume and to provide a prognostic indicator in assessing treatment response. Digital breast tomosynthesis (DBT) was developed and has increased interest in clinical settings due to its higher sensitivity for breast cancer detection compared to full-field digital mammography (FFDM). Purpose: To evaluate the accuracy of DBT in assessing response to NST compared to FFDM, ultrasound (US), and magnetic resonance imaging (MRI) in breast cancer patients. Material and Methods: In this retrospective study, 95 stages II–III breast cancer patients undergoing NST and subsequent surgeries were enrolled. After NST, the longest diameter of residual tumor measured by DBT, FFDM, US, and MRI was compared with pathology. Agreements and correlations of tumor size were assessed, and the diagnostic performance for predicting pathologic complete response (pCR) was evaluated. Results: Mean residual tumor size after NST was 19.9 mm for DBT, 18.7 mm for FFDM, 16.0 mm for US, and 18.4 mm for MRI, compared with 17.9 mm on pathology. DBT and MRI correlated better with pathology than that of FFDM and US. The ICC values were 0.85, 0.87, 0.74, and 0.77, respectively. Twenty-five patients (26.3%) achieved pCR after NST. For predicting pCR, area under the receiver operating characteristic (ROC) curve for DBT, FFDM, US, and MRI were 0.79, 0.66, 0.68, and 0.77, respectively. Conclusion: DBT has good correlation with histopathologyBackground: The goals of neoadjuvant systemic therapy (NST) are to reduce tumor volume and to provide a prognostic indicator in assessing treatment response. Digital breast tomosynthesis (DBT) was developed and has increased interest in clinical settings due to its higher sensitivity for breast cancer detection compared to full-field digital mammography (FFDM). Purpose: To evaluate the accuracy of DBT in assessing response to NST compared to FFDM, ultrasound (US), and magnetic resonance imaging (MRI) in breast cancer patients. Material and Methods: In this retrospective study, 95 stages II–III breast cancer patients undergoing NST and subsequent surgeries were enrolled. After NST, the longest diameter of residual tumor measured by DBT, FFDM, US, and MRI was compared with pathology. Agreements and correlations of tumor size were assessed, and the diagnostic performance for predicting pathologic complete response (pCR) was evaluated. Results: Mean residual tumor size after NST was 19.9 mm for DBT, 18.7 mm for FFDM, 16.0 mm for US, and 18.4 mm for MRI, compared with 17.9 mm on pathology. DBT and MRI correlated better with pathology than that of FFDM and US. The ICC values were 0.85, 0.87, 0.74, and 0.77, respectively. Twenty-five patients (26.3%) achieved pCR after NST. For predicting pCR, area under the receiver operating characteristic (ROC) curve for DBT, FFDM, US, and MRI were 0.79, 0.66, 0.68, and 0.77, respectively. Conclusion: DBT has good correlation with histopathology for measuring residual tumor size after NST. DBT was comparable to MRI in assessing tumor response after completion of NST. … (more)
- Is Part Of:
- Acta radiologica open. Volume 10:Number 12(2021)
- Journal:
- Acta radiologica open
- Issue:
- Volume 10:Number 12(2021)
- Issue Display:
- Volume 10, Issue 12 (2021)
- Year:
- 2021
- Volume:
- 10
- Issue:
- 12
- Issue Sort Value:
- 2021-0010-0012-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-12-03
- Subjects:
- breast cancer -- neoadjuvant -- mammography -- digital breast tomosynthesis -- ultrasound -- magnetic resonance imaging
Radiology -- Periodicals
Diagnostic Imaging -- Periodicals
Radiology
Periodicals
616.075705 - Journal URLs:
- http://arr.sagepub.com/ ↗
http://arr.sagepub.com/ ↗
http://www.uk.sagepub.com ↗
http://www.ncbi.nlm.nih.gov/pmc/journals/2704/ ↗ - DOI:
- 10.1177/20584601211063746 ↗
- Languages:
- English
- ISSNs:
- 2058-4601
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18249.xml