Does ARFI elastography complement B-mode ultrasonography in the radiological diagnosis of idiopathic granulomatous mastitis and invasive ductal carcinoma?. (January 2022)
- Record Type:
- Journal Article
- Title:
- Does ARFI elastography complement B-mode ultrasonography in the radiological diagnosis of idiopathic granulomatous mastitis and invasive ductal carcinoma?. (January 2022)
- Main Title:
- Does ARFI elastography complement B-mode ultrasonography in the radiological diagnosis of idiopathic granulomatous mastitis and invasive ductal carcinoma?
- Authors:
- Toprak, Nurşen
Toktas, Osman
Ince, Suat
Gunduz, Ali Mahir
Yokus, Adem
Akdeniz, Hüseyin
Ozkacmaz, Sercan - Abstract:
- Background: Idiopathic granulomatous mastitis (IGM) is a chronic, unpleasant autoimmune inflammatory condition and is clinically and radiologically often confused with breast malignancy. Purpose: To investigate the contributions of qualitative and quantitative aspects of acoustic radiation force impulse (ARFI) elastography to the differential diagnosis between IGM and invasive ductal carcinoma (IDC) in the breast. Material and Methods: Ninety-four women with IDC and 39 with IGM were included in the study. Shear wave velocity (SWV) was calculated for all lesions using quantitative elastography. Next, each lesion's correspondence on qualitative elastographic images to those on the B-mode images was evaluated: pattern 1, no findings on elastography images; pattern 2, lesions that were bright inside; pattern 3, lesions that contained both bright and dark areas; and pattern 4, lesions that were dark inside. Pattern 4 was subdivided into 4a (dark area same size as lesion) and 4b (dark area larger than lesion size). Sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were calculated. Results: The mean SWV based on ARFI elastography was 3.78 ± 1.26 m/s for IGM and 5.34 ± 1.43 m/s for IDC lesions ( P < 0.05). Based on qualitative ARFI elastography, IDC lesions were mostly classified as pattern 4b, while IGM lesions were mostly classified as pattern 1 or 2 ( P = 0.01). Evaluation of both the qualitative and quantitative aspects ofBackground: Idiopathic granulomatous mastitis (IGM) is a chronic, unpleasant autoimmune inflammatory condition and is clinically and radiologically often confused with breast malignancy. Purpose: To investigate the contributions of qualitative and quantitative aspects of acoustic radiation force impulse (ARFI) elastography to the differential diagnosis between IGM and invasive ductal carcinoma (IDC) in the breast. Material and Methods: Ninety-four women with IDC and 39 with IGM were included in the study. Shear wave velocity (SWV) was calculated for all lesions using quantitative elastography. Next, each lesion's correspondence on qualitative elastographic images to those on the B-mode images was evaluated: pattern 1, no findings on elastography images; pattern 2, lesions that were bright inside; pattern 3, lesions that contained both bright and dark areas; and pattern 4, lesions that were dark inside. Pattern 4 was subdivided into 4a (dark area same size as lesion) and 4b (dark area larger than lesion size). Sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were calculated. Results: The mean SWV based on ARFI elastography was 3.78 ± 1.26 m/s for IGM and 5.34 ± 1.43 m/s for IDC lesions ( P < 0.05). Based on qualitative ARFI elastography, IDC lesions were mostly classified as pattern 4b, while IGM lesions were mostly classified as pattern 1 or 2 ( P = 0.01). Evaluation of both the qualitative and quantitative aspects of ARFI elastography yielded a sensitivity of 89% and specificity of 84%. Conclusion: ARFI elastography may facilitate the differential diagnosis between IGM and IDC. … (more)
- Is Part Of:
- Acta radiologica. Volume 63:Number 1(2022)
- Journal:
- Acta radiologica
- Issue:
- Volume 63:Number 1(2022)
- Issue Display:
- Volume 63, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 63
- Issue:
- 1
- Issue Sort Value:
- 2022-0063-0001-0000
- Page Start:
- 28
- Page End:
- 34
- Publication Date:
- 2022-01
- Subjects:
- Idiopathic granulomatous mastitis -- invasive ductal carcinoma -- elastography -- shear wave velocity -- virtual touch tissue imaging
Radiology, Medical -- Periodicals
Radiography, Medical -- Periodicals
Radiotherapy -- Periodicals
616.0757 - Journal URLs:
- http://acr.sagepub.com ↗
http://ar.rsmjournals.com ↗
http://www.uk.sagepub.com/home.nav ↗
http://informahealthcare.com/loi/ard ↗
http://www.tandf.co.uk/journals/titles/02841851.asp ↗ - DOI:
- 10.1177/0284185120983568 ↗
- Languages:
- English
- ISSNs:
- 0284-1851
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0662.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18237.xml