Direct and Label‐Free Cell Status Monitoring of Spheroids and Microcarriers Using Microfluidic Impedance Cytometry. Issue 21 (24th March 2021)
- Record Type:
- Journal Article
- Title:
- Direct and Label‐Free Cell Status Monitoring of Spheroids and Microcarriers Using Microfluidic Impedance Cytometry. Issue 21 (24th March 2021)
- Main Title:
- Direct and Label‐Free Cell Status Monitoring of Spheroids and Microcarriers Using Microfluidic Impedance Cytometry
- Authors:
- Gong, Lingyan
Petchakup, Chayakorn
Shi, Pujiang
Tan, Pei Leng
Tan, Lay Poh
Tay, Chor Yong
Hou, Han Wei - Abstract:
- Abstract: 3D cellular spheroids/microcarriers (100 µm–1 mm) are widely used in biomanufacturing, and non‐invasive biosensors are useful to monitor cell quality in bioprocesses. In this work, a novel microfluidic approach for label‐free and continuous‐flow monitoring of single spheroid/microcarrier (hydrogel and Cytodex) based on electrical impedance spectroscopy using co‐planar Field's metal electrodes is reported. Through numerical simulation and experimental validation, two unique impedance signatures (|ZLF | (60 kHz), |ZHF | (1 MHz)) which are optimal for spheroid growth and viability monitoring are identified. Using a closed‐loop recirculation system, it is demonstrated that |ZLF | increases with breast cancer (MCF‐7) spheroid biomass, while higher opacity (impedance ratio |ZHF |/|ZLF |) indicates cell death due to compromised cell membrane. Anti‐cancer drug (paclitaxel)‐treated spheroids also exhibit lower |ZLF | with increased cell dissociation. Interestingly, impedance characterization of adipose‐derived mesenchymal stem cell differentiation on Cytodex microcarriers reveals that adipogenic cells (higher intracellular lipid content) exhibit higher impedance than osteogenic cells (more conductive due to calcium ions) for both microcarriers and single cell level. Taken together, the developed platform offers great versatility for multi‐parametric analysis of spheroids/microcarriers at high throughput (≈1 particle/s), and can be readily integrated into bioreactors forAbstract: 3D cellular spheroids/microcarriers (100 µm–1 mm) are widely used in biomanufacturing, and non‐invasive biosensors are useful to monitor cell quality in bioprocesses. In this work, a novel microfluidic approach for label‐free and continuous‐flow monitoring of single spheroid/microcarrier (hydrogel and Cytodex) based on electrical impedance spectroscopy using co‐planar Field's metal electrodes is reported. Through numerical simulation and experimental validation, two unique impedance signatures (|ZLF | (60 kHz), |ZHF | (1 MHz)) which are optimal for spheroid growth and viability monitoring are identified. Using a closed‐loop recirculation system, it is demonstrated that |ZLF | increases with breast cancer (MCF‐7) spheroid biomass, while higher opacity (impedance ratio |ZHF |/|ZLF |) indicates cell death due to compromised cell membrane. Anti‐cancer drug (paclitaxel)‐treated spheroids also exhibit lower |ZLF | with increased cell dissociation. Interestingly, impedance characterization of adipose‐derived mesenchymal stem cell differentiation on Cytodex microcarriers reveals that adipogenic cells (higher intracellular lipid content) exhibit higher impedance than osteogenic cells (more conductive due to calcium ions) for both microcarriers and single cell level. Taken together, the developed platform offers great versatility for multi‐parametric analysis of spheroids/microcarriers at high throughput (≈1 particle/s), and can be readily integrated into bioreactors for long‐term and remote monitoring of biomass and cell quality. Abstract : Non‐invasive and real‐time monitoring of microcarriers and 3D cell cultures are important in biomanufacturing and bioprocesses. This article introduces a low‐cost microfluidic impedance cytometer with Field's metal electrodes for label‐free and continuous‐flow monitoring of spheroids/microcarriers based on changes in impedance signatures. Potential applications include tracking of cell proliferation (biomass), cell viability, and stem cell differentiation on hydrogel and commercial microcarriers. … (more)
- Is Part Of:
- Small. Volume 17:Issue 21(2021)
- Journal:
- Small
- Issue:
- Volume 17:Issue 21(2021)
- Issue Display:
- Volume 17, Issue 21 (2021)
- Year:
- 2021
- Volume:
- 17
- Issue:
- 21
- Issue Sort Value:
- 2021-0017-0021-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2021-03-24
- Subjects:
- biomanufacturing -- impedance cytometry -- label‐free -- microfluidics -- stem cell differentiation
Nanotechnology -- Periodicals
Nanoparticles -- Periodicals
Microtechnology -- Periodicals
620.5 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1613-6829 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/smll.202007500 ↗
- Languages:
- English
- ISSNs:
- 1613-6810
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8309.952000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18231.xml