Do trabecular metal and cancellous titanium implants reduce the risk of late haematogenous infection? An experimental study in rabbits. Issue 6 (November 2021)
- Record Type:
- Journal Article
- Title:
- Do trabecular metal and cancellous titanium implants reduce the risk of late haematogenous infection? An experimental study in rabbits. Issue 6 (November 2021)
- Main Title:
- Do trabecular metal and cancellous titanium implants reduce the risk of late haematogenous infection? An experimental study in rabbits
- Authors:
- Komnos, George
Banios, Konstantinos
Kolonia, Konstantina
Poultsides, Lazaros A
Petinaki, Efthimia
Sarrou, Styliani
Zintzaras, Elias
Karachalios, Theofilos - Abstract:
- Aim: This study evaluated the late resistance to haematogenous contamination by microbial pathogens of implants and bone-implant interface and the development of late clinical infection when cementless components with different surface or structural properties are implanted. Material and methods: 50 adult male New Zealand white rabbits were divided into 5 groups of 10 animals each. In Group A smooth titanium, in Group B grit blasted titanium, in Group C HA-coated titanium, in Group D trabecular metal and in group E cancellous titanium rods were implanted in the right proximal tibia. Four weeks later, 1 ml of inoculum of a standardised CA-MRSA strain (3 × 10 8 cfu/ml) was injected through a femoral artery catheter (groups B, C, D, E) while in group A, 1 ml of sterile saline was injected in a similar way (control group). Subjects were killed 8 weeks after the initial procedure and 3 samples of each tibial specimen were subjected to conventional cultures and PCR studies. Results: The number of the specimens (conventional cultures and PCR studies) contaminated by the standardized pathogen was as follows: Group A: 0/10, Group B: 7/10, Group C: 6/10, Group D; 5/10 and Group E: 5/10. Comparing the number of colony form units isolated from the implant samples, Group B (GB titanium) showed statistically significantly higher values (Mann-Whitney test) compared to Group C ( p = 0.044), Group D ( p = 0.040) and Group E ( p = 0.038). Local active infection was observed in 6 animals: 3Aim: This study evaluated the late resistance to haematogenous contamination by microbial pathogens of implants and bone-implant interface and the development of late clinical infection when cementless components with different surface or structural properties are implanted. Material and methods: 50 adult male New Zealand white rabbits were divided into 5 groups of 10 animals each. In Group A smooth titanium, in Group B grit blasted titanium, in Group C HA-coated titanium, in Group D trabecular metal and in group E cancellous titanium rods were implanted in the right proximal tibia. Four weeks later, 1 ml of inoculum of a standardised CA-MRSA strain (3 × 10 8 cfu/ml) was injected through a femoral artery catheter (groups B, C, D, E) while in group A, 1 ml of sterile saline was injected in a similar way (control group). Subjects were killed 8 weeks after the initial procedure and 3 samples of each tibial specimen were subjected to conventional cultures and PCR studies. Results: The number of the specimens (conventional cultures and PCR studies) contaminated by the standardized pathogen was as follows: Group A: 0/10, Group B: 7/10, Group C: 6/10, Group D; 5/10 and Group E: 5/10. Comparing the number of colony form units isolated from the implant samples, Group B (GB titanium) showed statistically significantly higher values (Mann-Whitney test) compared to Group C ( p = 0.044), Group D ( p = 0.040) and Group E ( p = 0.038). Local active infection was observed in 6 animals: 3 in Group B; 1 in Group C, 1 in Group D, and 1 in Group E. Conclusions: Modern cementless implants (trabecular metal and cancellous titanium) showed a lower risk of implant contamination and late clinical haematogenous infection. … (more)
- Is Part Of:
- Hip international. Volume 31:Issue 6(2021)
- Journal:
- Hip international
- Issue:
- Volume 31:Issue 6(2021)
- Issue Display:
- Volume 31, Issue 6 (2021)
- Year:
- 2021
- Volume:
- 31
- Issue:
- 6
- Issue Sort Value:
- 2021-0031-0006-0000
- Page Start:
- 766
- Page End:
- 773
- Publication Date:
- 2021-11
- Subjects:
- Cancellous titanium -- implant -- infection risk -- late haematogenous infection -- trabecular metal
Hip joint -- Pathophysiology -- Periodicals
Hip joint -- Diseases -- Periodicals
Hip joint -- Surgery -- Periodicals
617.581005 - Journal URLs:
- http://www.uk.sagepub.com/home.nav ↗
http://journals.sagepub.com/home/hpi ↗ - DOI:
- 10.1177/1120700020928891 ↗
- Languages:
- English
- ISSNs:
- 1120-7000
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18234.xml