Detection of coronary microembolisation by Doppler ultrasound during percutaneous coronary interventions. Issue 9 (15th August 2005)
- Record Type:
- Journal Article
- Title:
- Detection of coronary microembolisation by Doppler ultrasound during percutaneous coronary interventions. Issue 9 (15th August 2005)
- Main Title:
- Detection of coronary microembolisation by Doppler ultrasound during percutaneous coronary interventions
- Authors:
- Bahrmann, P
Figulla, H R
Wagner, M
Ferrari, M
Voss, A
Werner, G S - Abstract:
- Abstract : Objective: To validate an intracoronary Doppler ultrasound device for high intensity transient signals (HITS) detection and to assess the incidence of HITS during percutaneous coronary intervention (PCI). Methods and Results: In an in vitro model, particle count and number of HITS detected by an intracoronary 0.014 inch Doppler wire were closely correlated ( r = 0.97, p < 0.001). In the clinical study, 32 patients (mean (SD) age 61 (11) years; 23 men, nine women) with coronary artery disease were treated with balloon dilatation and stent implantation for a single vessel stenosis. In these patients HITS were detected during PCI in 84% (27 of 32). Reproducibility ( r = 0.99, p < 0.001) and interobserver agreement ( r = 0.84, p < 0.001) of HITS counts were significant. The number of HITS after stent implantation was significantly higher than after balloon dilatation (11 (7) v 2 (4), p < 0.001). Postprocedural coronary flow velocity reserve (CFVR) was < 2.0 in 55% (16 of 29) of all patients after balloon dilatation and < 2.0 in 23% (six of 26) after stent implantation. The number of HITS after stent implantation did not differ significantly between patients with CFVR < 2.0 and patients with CFVR ⩾ 2.0 (12 (8) v 10 (7), not significant). Conclusions: Embolic particles can be detected as HITS by an intracoronary Doppler ultrasound device. Coronary microembolism is often observed during PCI, especially after stent implantation. However, the incidence of HITS aloneAbstract : Objective: To validate an intracoronary Doppler ultrasound device for high intensity transient signals (HITS) detection and to assess the incidence of HITS during percutaneous coronary intervention (PCI). Methods and Results: In an in vitro model, particle count and number of HITS detected by an intracoronary 0.014 inch Doppler wire were closely correlated ( r = 0.97, p < 0.001). In the clinical study, 32 patients (mean (SD) age 61 (11) years; 23 men, nine women) with coronary artery disease were treated with balloon dilatation and stent implantation for a single vessel stenosis. In these patients HITS were detected during PCI in 84% (27 of 32). Reproducibility ( r = 0.99, p < 0.001) and interobserver agreement ( r = 0.84, p < 0.001) of HITS counts were significant. The number of HITS after stent implantation was significantly higher than after balloon dilatation (11 (7) v 2 (4), p < 0.001). Postprocedural coronary flow velocity reserve (CFVR) was < 2.0 in 55% (16 of 29) of all patients after balloon dilatation and < 2.0 in 23% (six of 26) after stent implantation. The number of HITS after stent implantation did not differ significantly between patients with CFVR < 2.0 and patients with CFVR ⩾ 2.0 (12 (8) v 10 (7), not significant). Conclusions: Embolic particles can be detected as HITS by an intracoronary Doppler ultrasound device. Coronary microembolism is often observed during PCI, especially after stent implantation. However, the incidence of HITS alone does not explain a reduced CFVR after PCI. … (more)
- Is Part Of:
- Heart. Volume 91:Issue 9(2005)
- Journal:
- Heart
- Issue:
- Volume 91:Issue 9(2005)
- Issue Display:
- Volume 91, Issue 9 (2005)
- Year:
- 2005
- Volume:
- 91
- Issue:
- 9
- Issue Sort Value:
- 2005-0091-0009-0000
- Page Start:
- 1186
- Page End:
- 1192
- Publication Date:
- 2005-08-15
- Subjects:
- APV, average peak velocity -- CFVR, coronary flow velocity reserve -- CK, creatine kinase -- HITS, high intensity transient signals -- PCI, percutaneous coronary intervention
angioplasty -- blood flow -- coronary disease -- embolism -- stents -- ultrasonography
Heart -- Diseases -- Treatment -- Periodicals
Cardiology -- Periodicals
616.12 - Journal URLs:
- http://www.bmj.com/archive ↗
http://heart.bmj.com ↗
http://www.heartjnl.com ↗ - DOI:
- 10.1136/hrt.2004.048629 ↗
- Languages:
- English
- ISSNs:
- 1355-6037
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18225.xml