A comparison of perimetric results with the Medmont and Humphrey perimeters. Issue 6 (1st June 2003)
- Record Type:
- Journal Article
- Title:
- A comparison of perimetric results with the Medmont and Humphrey perimeters. Issue 6 (1st June 2003)
- Main Title:
- A comparison of perimetric results with the Medmont and Humphrey perimeters
- Authors:
- Landers, J
Sharma, A
Goldberg, I
Graham, S - Abstract:
- Abstract : Background: The Humphrey field analyser (HFA), Humphrey-Zeiss frequency doubling perimeter, and the Medmont automated perimeter (MAP) are three commonly used automated perimeters with threshold achromatic methodologies. Visual field loss may be detected earlier with strategies that target cell lines with reduced redundancy or which suffer selective damage. Method: To compare these three perimeters, 63 subjects who were glaucoma suspects, ocular hypertensives, glaucoma patients, or normal controls were recruited selectively. All subjects underwent testing using MAP central threshold, MAP flicker perimetry, HFA full threshold, HFA SITA perimetry, HFA short wavelength perimetry (SWAP), and frequency doubling perimetry (FDP). After visual field testing, equivalent tests were compared: MAP central threshold with HFA full threshold and HFA SITA perimetry; Medmont flicker perimetry with HFA SWAP and FDP. Results: On analysis of the MAP central threshold a kappa statistic and an area under the receiver operator curve (AUC) of 0.90 and 0.94, respectively, were found compared with HFA full threshold strategies, and 0.87 and 0.92 respectively, compared with HFA SITA. For MAP flicker a kappa statistic and an AUC of 0.65 and 0.81, respectively, were found compared with HFA SWAP and 0.87 and 0.96, respectively, compared with FDP. A quadrant analysis and comparison of mean defect between tests was also highly significant. Conclusion: Medmont and Humphrey perimeters correlatedAbstract : Background: The Humphrey field analyser (HFA), Humphrey-Zeiss frequency doubling perimeter, and the Medmont automated perimeter (MAP) are three commonly used automated perimeters with threshold achromatic methodologies. Visual field loss may be detected earlier with strategies that target cell lines with reduced redundancy or which suffer selective damage. Method: To compare these three perimeters, 63 subjects who were glaucoma suspects, ocular hypertensives, glaucoma patients, or normal controls were recruited selectively. All subjects underwent testing using MAP central threshold, MAP flicker perimetry, HFA full threshold, HFA SITA perimetry, HFA short wavelength perimetry (SWAP), and frequency doubling perimetry (FDP). After visual field testing, equivalent tests were compared: MAP central threshold with HFA full threshold and HFA SITA perimetry; Medmont flicker perimetry with HFA SWAP and FDP. Results: On analysis of the MAP central threshold a kappa statistic and an area under the receiver operator curve (AUC) of 0.90 and 0.94, respectively, were found compared with HFA full threshold strategies, and 0.87 and 0.92 respectively, compared with HFA SITA. For MAP flicker a kappa statistic and an AUC of 0.65 and 0.81, respectively, were found compared with HFA SWAP and 0.87 and 0.96, respectively, compared with FDP. A quadrant analysis and comparison of mean defect between tests was also highly significant. Conclusion: Medmont and Humphrey perimeters correlated well; both may be used for clinical and research purposes with similar confidence. … (more)
- Is Part Of:
- British journal of ophthalmology. Volume 87:Issue 6(2003)
- Journal:
- British journal of ophthalmology
- Issue:
- Volume 87:Issue 6(2003)
- Issue Display:
- Volume 87, Issue 6 (2003)
- Year:
- 2003
- Volume:
- 87
- Issue:
- 6
- Issue Sort Value:
- 2003-0087-0006-0000
- Page Start:
- 690
- Page End:
- 694
- Publication Date:
- 2003-06-01
- Subjects:
- Medmont perimetry -- Humphrey perimetry -- visual fields
AAP, achromatic automated perimetry -- AUC, area under the receiver operator curve -- FDP, frequency doubling perimetry -- HFA, Humphrey field analyser -- MAP, Medmont automated perimeter -- SITA, Swedish Interactive Thresholding Algorithm -- SWAP, short wavelength automated perimetry
Ophthalmology -- Periodicals
617.7 - Journal URLs:
- http://bjo.bmj.com/ ↗
http://bjo.bmjjournals.com/ ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/bjo.87.6.690 ↗
- Languages:
- English
- ISSNs:
- 0007-1161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18185.xml