Biomarkers for the diagnosis of venous thromboembolism: D-dimer, thrombin generation, procoagulant phospholipid and soluble P-selectin. Issue 11 (9th August 2018)
- Record Type:
- Journal Article
- Title:
- Biomarkers for the diagnosis of venous thromboembolism: D-dimer, thrombin generation, procoagulant phospholipid and soluble P-selectin. Issue 11 (9th August 2018)
- Main Title:
- Biomarkers for the diagnosis of venous thromboembolism: D-dimer, thrombin generation, procoagulant phospholipid and soluble P-selectin
- Authors:
- Riva, Nicoletta
Vella, Kevin
Hickey, Kieron
Bertù, Lorenza
Zammit, Daniel
Spiteri, Silvana
Kitchen, Steve
Makris, Michael
Ageno, Walter
Gatt, Alex - Abstract:
- Abstract : Background: The diagnostic algorithm for venous thromboembolism (VTE) currently involves a composite of pre-test probability, D-dimer and imaging. Other laboratory tests, however, may assist in the identification of patients with VTE. Aim: To assess the accuracy of different coagulation tests (D-dimer, thrombin generation, phospholipid-dependent (PPL) clotting time, soluble P-selectin (sP-selectin)) as biomarkers of acute VTE. Methods: Random samples arriving at the Coagulation Laboratory at Mater Dei Hospital (Msida, Malta) from the Accident and Emergency Department with a request for D-dimer measurement were collected between August 2015 and February 2016. The following tests were performed: Innovance D-dimer (Siemens Healthcare Diagnostics), HemosIL D-dimer HS (Instrumentation Laboratory), thrombin generation (using the calibrated automated thrombogram), STA Procoag PPL (Diagnostica Stago) and sP-selectin (Affymetrix; eBioscience). VTE was objectively confirmed by compression ultrasonography, CT pulmonary angiography or ventilation/perfusion lung scan. Results: 100 samples were collected (33 with VTE). A strong positive linear correlation was found between the two D-dimer tests (r=0.97, p<0.001). Patients with VTE showed significantly higher sP-selectin concentrations compared with patients without VTE (75.7 ng/mL vs 53.0 ng/mL, p<0.001). In the random forest plot, the two D-dimer assays showed the highest variable importance, followed by sP-selectin. AAbstract : Background: The diagnostic algorithm for venous thromboembolism (VTE) currently involves a composite of pre-test probability, D-dimer and imaging. Other laboratory tests, however, may assist in the identification of patients with VTE. Aim: To assess the accuracy of different coagulation tests (D-dimer, thrombin generation, phospholipid-dependent (PPL) clotting time, soluble P-selectin (sP-selectin)) as biomarkers of acute VTE. Methods: Random samples arriving at the Coagulation Laboratory at Mater Dei Hospital (Msida, Malta) from the Accident and Emergency Department with a request for D-dimer measurement were collected between August 2015 and February 2016. The following tests were performed: Innovance D-dimer (Siemens Healthcare Diagnostics), HemosIL D-dimer HS (Instrumentation Laboratory), thrombin generation (using the calibrated automated thrombogram), STA Procoag PPL (Diagnostica Stago) and sP-selectin (Affymetrix; eBioscience). VTE was objectively confirmed by compression ultrasonography, CT pulmonary angiography or ventilation/perfusion lung scan. Results: 100 samples were collected (33 with VTE). A strong positive linear correlation was found between the two D-dimer tests (r=0.97, p<0.001). Patients with VTE showed significantly higher sP-selectin concentrations compared with patients without VTE (75.7 ng/mL vs 53.0 ng/mL, p<0.001). In the random forest plot, the two D-dimer assays showed the highest variable importance, followed by sP-selectin. A sP-selectin cut-off of 74.8 ng/mL was associated with 72.7% sensitivity and 78.2% specificity for acute VTE in our cohort. Conclusion: Our results confirmed D-dimer as the main biomarker of VTE and speculated a role for sP-selectin. The impact of thrombin generation was limited and no role emerged for the PPL clotting time. These observations need to be confirmed in large management studies. … (more)
- Is Part Of:
- Journal of clinical pathology. Volume 71:Issue 11(2018)
- Journal:
- Journal of clinical pathology
- Issue:
- Volume 71:Issue 11(2018)
- Issue Display:
- Volume 71, Issue 11 (2018)
- Year:
- 2018
- Volume:
- 71
- Issue:
- 11
- Issue Sort Value:
- 2018-0071-0011-0000
- Page Start:
- 1015
- Page End:
- 1022
- Publication Date:
- 2018-08-09
- Subjects:
- biomarkers -- diagnosis -- venous thromboembolism
Pathology -- Periodicals
Pathology, Molecular -- Periodicals
616.0705 - Journal URLs:
- http://jcp.bmjjournals.com ↗
http://jcp.bmjjournals.com/content/by/year ↗
http://www.pubmedcentral.nih.gov/tocrender.fcgi?journal=162&action=archive ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/jclinpath-2018-205293 ↗
- Languages:
- English
- ISSNs:
- 0021-9746
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18201.xml