Determinants of implantable defibrillator discharges in high-risk patients with hypertrophic cardiomyopathy. Issue 9 (14th August 2007)
- Record Type:
- Journal Article
- Title:
- Determinants of implantable defibrillator discharges in high-risk patients with hypertrophic cardiomyopathy. Issue 9 (14th August 2007)
- Main Title:
- Determinants of implantable defibrillator discharges in high-risk patients with hypertrophic cardiomyopathy
- Authors:
- Woo, Anna
Monakier, Daniel
Harris, Louise
Hill, Ann
Shah, Prasad
Wigle, E Douglas
Rakowski, Harry
Rozenblyum, Evelyn
Cameron, Douglas A - Abstract:
- Abstract : Objectives: To identify the determinants of appropriate and inappropriate implantable cardioverter-defibrillator (ICD) discharges in patients with hypertrophic cardiomyopathy (HCM). Design: Retrospective cohort study. Setting: ICD clinic at an academic hospital. Patients: 61 patients with HCM who received ICDs for the primary or secondary prevention of sudden cardiac death (SCD). Outcome measures: ( a ) Analysis of appropriate and inappropriate ICD discharges; ( b ) predictors of ICD discharges. Results: Mean (SD) age at ICD insertion was 46 (18) years (range 10–79). Follow-up time was 40 (27) months (range 7–151). Eight patients experienced an appropriate discharge, occurring 24.5 (13.6) months after ICD insertion. Appropriate ICD intervention was more common in the secondary (36%) than the primary (8%) prevention group (p = 0.02). Inappropriate ICD discharges occurred in 20 (33%) patients. Multivariate Cox regression analysis identified two significant predictors of inappropriate ICD discharges: ( a ) age <30 years at the time of ICD insertion (hazard ratio (HR) = 3.0 (95% CI 1.1 to 8.0; p = 0.03) and ( b ) history of atrial fibrillation (HR = 3.1 (95% CI 1.2 to 8.1; p = 0.02). Conclusions: ICDs are effective in the prevention of SCD in HCM. However, there is a high incidence of inappropriate ICD discharges.
- Is Part Of:
- Heart. Volume 93:Issue 9(2007)
- Journal:
- Heart
- Issue:
- Volume 93:Issue 9(2007)
- Issue Display:
- Volume 93, Issue 9 (2007)
- Year:
- 2007
- Volume:
- 93
- Issue:
- 9
- Issue Sort Value:
- 2007-0093-0009-0000
- Page Start:
- 1044
- Page End:
- 1045
- Publication Date:
- 2007-08-14
- Subjects:
- AF, atrial fibrillation -- AT, atrial tachycardia -- HCM, hypertrophic cardiomyopathy -- HR, hazard ratio -- ICD, implantable cardioverter-defibrillator -- SCD, sudden cardiac death -- VF, ventricular fibrillation -- VT, ventricular tachycardia
hypertrophic cardiomyopathy -- implantable cardioverter-defibrillator -- sudden cardiac death -- atrial fibrillation -- survival
Heart -- Diseases -- Treatment -- Periodicals
Cardiology -- Periodicals
616.12 - Journal URLs:
- http://www.bmj.com/archive ↗
http://heart.bmj.com ↗
http://www.heartjnl.com ↗ - DOI:
- 10.1136/hrt.2006.090290 ↗
- Languages:
- English
- ISSNs:
- 1355-6037
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18183.xml