Single versus sequential testing with scanning peripheral anterior chamber depth analyser, IOLMaster and anterior segment optical coherence tomography for the detection of narrow angles. Issue 10 (17th January 2011)
- Record Type:
- Journal Article
- Title:
- Single versus sequential testing with scanning peripheral anterior chamber depth analyser, IOLMaster and anterior segment optical coherence tomography for the detection of narrow angles. Issue 10 (17th January 2011)
- Main Title:
- Single versus sequential testing with scanning peripheral anterior chamber depth analyser, IOLMaster and anterior segment optical coherence tomography for the detection of narrow angles
- Authors:
- Chang, Dolly S
Sakata, Lisandro M
Aung, Tin
He, Ming-Guang
Lavanya, Raghavan
Kashiwagi, Kenji
Friedman, David S - Abstract:
- Abstract : Background: Scanning peripheral anterior chamber depth analyser (SPAC), IOLMaster and anterior segment optical coherence tomography (AS-OCT) are devices that can screen non-invasively for narrow angles (NAs) and may reduce the need for gonioscopy, especially where the availability of ophthalmologists is limited. When used individually to detect NAs, neither SPAC, AS-OCT nor IOLMaster were able to achieve both high sensitivity and specificity when using gonioscopy as a gold standard. Aims: To assess whether sequential testing improves discrimination of NAs over single testing. Methods: In a prospective community-based cross-sectional study in Singapore, 2047 phakic right eyes underwent SPAC, IOLMaster and AS-OCT. NA eyes were defined as present when Shaffer scores were 0 or 1 in ≥2 quadrants on gonioscopy. Sensitivities and specificities of single and sequential testing were compared. Results: At a fixed specificity of 95%, sensitivities in detecting NA eyes were 57.8% (95% CI 52.7% to 62.7%) for SPAC, 43.3% (95% CI 38.3% to 48.3%) for IOLMaster and 52.1% (95% CI 46.4% to 57.7%) for AS-OCT. After sequential testing using SPAC followed by AS-OCT, the sensitivity rose to 70.3% (95% CI 65.5% to 74.8%) while specificity remained at 94.3% (95% CI 93.1% to 95.4%), with sensitivity significantly higher than single testing alone (p<0.001). Conclusion: Sequential testing significantly improves the accuracy of detecting NAs and may be useful in screening settings.
- Is Part Of:
- British journal of ophthalmology. Volume 95:Issue 10(2011)
- Journal:
- British journal of ophthalmology
- Issue:
- Volume 95:Issue 10(2011)
- Issue Display:
- Volume 95, Issue 10 (2011)
- Year:
- 2011
- Volume:
- 95
- Issue:
- 10
- Issue Sort Value:
- 2011-0095-0010-0000
- Page Start:
- 1410
- Page End:
- 1414
- Publication Date:
- 2011-01-17
- Subjects:
- Anterior chamber -- angle -- public health -- epidemiology -- diagnostic tests/investigation
Ophthalmology -- Periodicals
617.7 - Journal URLs:
- http://bjo.bmj.com/ ↗
http://bjo.bmjjournals.com/ ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/bjo.2009.175869 ↗
- Languages:
- English
- ISSNs:
- 0007-1161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: