Can the appropriateness of eye care be measured through cross-sectional retrospective patient record review in eye care practices in Australia? The iCareTrack feasibility study. Issue 3 (4th March 2019)
- Record Type:
- Journal Article
- Title:
- Can the appropriateness of eye care be measured through cross-sectional retrospective patient record review in eye care practices in Australia? The iCareTrack feasibility study. Issue 3 (4th March 2019)
- Main Title:
- Can the appropriateness of eye care be measured through cross-sectional retrospective patient record review in eye care practices in Australia? The iCareTrack feasibility study
- Authors:
- Ho, Kam Chun
Rahardjo, Dian
Stapleton, Fiona
Wiles, Louise
Hibbert, Peter D
White, Andrew J R
Hayen, Andrew
Jalbert, Isabelle - Abstract:
- Abstract : Objectives: The CareTrack study found that a wide range of appropriateness of care (ie, care in line with evidence-based or consensus-based guidelines) was delivered across many health conditions in Australia. This study therefore aimed to demonstrate the feasibility of using the CareTrack method (a retrospective onsite record review) to measure the appropriateness of eye care delivery. Design: Cross-sectional feasibility study. Setting and participants: Two hundred and thirteen patient records randomly selected from eight optometry and ophthalmology practices in Australia, selected through a combination of convenience and maximum variation sampling. Methods: Retrospective record review designed to assess the alignment between eye care delivered and 93 clinical indicators (Delphi method involving 11 experts) extracted from evidence-based clinical practice guidelines. Primary outcome measure: Number of eligible patient records, sampling rates and data collection time. This feasibility study also tested the ability of 93 clinical indicators to measure percentage appropriate eye care for preventative, glaucoma and diabetic eye care. A secondary outcome was the percentage of practitioner–patient encounters at which appropriate eye care was received. Results: A median of 20 records (range 9 to 63) per practice were reviewed. Data collection time ranged from 3 to 5.5 hours (median 3.5). The most effective sampling strategy involved random letter generation followed byAbstract : Objectives: The CareTrack study found that a wide range of appropriateness of care (ie, care in line with evidence-based or consensus-based guidelines) was delivered across many health conditions in Australia. This study therefore aimed to demonstrate the feasibility of using the CareTrack method (a retrospective onsite record review) to measure the appropriateness of eye care delivery. Design: Cross-sectional feasibility study. Setting and participants: Two hundred and thirteen patient records randomly selected from eight optometry and ophthalmology practices in Australia, selected through a combination of convenience and maximum variation sampling. Methods: Retrospective record review designed to assess the alignment between eye care delivered and 93 clinical indicators (Delphi method involving 11 experts) extracted from evidence-based clinical practice guidelines. Primary outcome measure: Number of eligible patient records, sampling rates and data collection time. This feasibility study also tested the ability of 93 clinical indicators to measure percentage appropriate eye care for preventative, glaucoma and diabetic eye care. A secondary outcome was the percentage of practitioner–patient encounters at which appropriate eye care was received. Results: A median of 20 records (range 9 to 63) per practice were reviewed. Data collection time ranged from 3 to 5.5 hours (median 3.5). The most effective sampling strategy involved random letter generation followed by sequential sampling. The appropriateness of care was 69% (95% CI 67% to 70%) for preventative eye care, 60% (95% CI 56% to 58%) for glaucoma and 63% (95% CI 57% to 69%) for diabetic eye care. Conclusions: Appropriateness of eye care can be measured effectively using retrospective record review of eye care practices and consensus-based care indicators. … (more)
- Is Part Of:
- BMJ open. Volume 9:Issue 3(2019)
- Journal:
- BMJ open
- Issue:
- Volume 9:Issue 3(2019)
- Issue Display:
- Volume 9, Issue 3 (2019)
- Year:
- 2019
- Volume:
- 9
- Issue:
- 3
- Issue Sort Value:
- 2019-0009-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-03-04
- Subjects:
- appropriateness of care -- record audit -- record review -- preventative eyecare -- glaucoma -- diabetic retinopathy
Medicine -- Research -- Periodicals
610.72 - Journal URLs:
- http://www.bmj.com/archive ↗
http://bmjopen.bmj.com/ ↗ - DOI:
- 10.1136/bmjopen-2018-024298 ↗
- Languages:
- English
- ISSNs:
- 2044-6055
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18130.xml