A non-electrostatic spacer for aerosol delivery. Issue 3 (September 1995)
- Record Type:
- Journal Article
- Title:
- A non-electrostatic spacer for aerosol delivery. Issue 3 (September 1995)
- Main Title:
- A non-electrostatic spacer for aerosol delivery.
- Authors:
- Bisgaard, H
Anhøj, J
Klug, B
Berg, E - Abstract:
- Abstract : A pear shaped non-electrostatic spacer, composed of steel with a volume of 250 ml and equipped with a facemask containing integrated inlet and outlet valves for inspiration and expiration, was compared with three plastic spacers. The plastic spacers were primed with repeated puffs from a budesonide pressurised metered dose inhaler (p-MDI) to minimise the electrostatic charge on the plastic. The procedure prolonged the half life (t1/2) of the aerosol in the Nebuhaler from nine to 32 seconds. A normal cleaning procedure reduced the aerosol t1/2 back to baseline. The t1/2 of the aerosol in the metal spacer was 27 seconds and independent of the use of p-MDI. In vitro the maximum dose of budesonide from a p-MDI, expressed as a percentage of the nominal dose, was 56% from the non-electrostatic spacer, 61% from the Nebuhaler, 45% from the Babyhaler, and 30% from the AeroChamber. In 124 children, age 6 months to 6 years, suspected to have asthma the non-electrostatic spacer delivered a mean total dose of budesonide aerosol of 39% of the nominal dose, which was significantly higher than the Babyhaler (28%), the Nebuhaler (21%), and the AeroChamber (19%). These differences were most pronounced in children younger than 4 years. The improved dose delivery from the small volume non-electrostatic spacer is probably related to the non-electrostatic spacer material and the valves which assured unidirectional airflow from the spacer without adding any dead space in the inspiratoryAbstract : A pear shaped non-electrostatic spacer, composed of steel with a volume of 250 ml and equipped with a facemask containing integrated inlet and outlet valves for inspiration and expiration, was compared with three plastic spacers. The plastic spacers were primed with repeated puffs from a budesonide pressurised metered dose inhaler (p-MDI) to minimise the electrostatic charge on the plastic. The procedure prolonged the half life (t1/2) of the aerosol in the Nebuhaler from nine to 32 seconds. A normal cleaning procedure reduced the aerosol t1/2 back to baseline. The t1/2 of the aerosol in the metal spacer was 27 seconds and independent of the use of p-MDI. In vitro the maximum dose of budesonide from a p-MDI, expressed as a percentage of the nominal dose, was 56% from the non-electrostatic spacer, 61% from the Nebuhaler, 45% from the Babyhaler, and 30% from the AeroChamber. In 124 children, age 6 months to 6 years, suspected to have asthma the non-electrostatic spacer delivered a mean total dose of budesonide aerosol of 39% of the nominal dose, which was significantly higher than the Babyhaler (28%), the Nebuhaler (21%), and the AeroChamber (19%). These differences were most pronounced in children younger than 4 years. The improved dose delivery from the small volume non-electrostatic spacer is probably related to the non-electrostatic spacer material and the valves which assured unidirectional airflow from the spacer without adding any dead space in the inspiratory channel. The non-electro-static spacer should improve the cost effectiveness of aerosol treatment and, as the counteracting effects of proming and recharging of the plastic from cleaning are avoided, should deliver a more reliable dose. … (more)
- Is Part Of:
- Archives of disease in childhood. Volume 73:Issue 3(1995)
- Journal:
- Archives of disease in childhood
- Issue:
- Volume 73:Issue 3(1995)
- Issue Display:
- Volume 73, Issue 3 (1995)
- Year:
- 1995
- Volume:
- 73
- Issue:
- 3
- Issue Sort Value:
- 1995-0073-0003-0000
- Page Start:
- 226
- Page End:
- 230
- Publication Date:
- 1995-09
- Subjects:
- Children -- Diseases -- Periodicals
Infants -- Diseases -- Periodicals
618.920005 - Journal URLs:
- http://adc.bmjjournals.com/ ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/adc.73.3.226 ↗
- Languages:
- English
- ISSNs:
- 0003-9888
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18142.xml