Twenty-four hour intraocular pressure monitoring with the SENSIMED Triggerfish contact lens: effect of body posture during sleep. Issue 10 (7th March 2017)
- Record Type:
- Journal Article
- Title:
- Twenty-four hour intraocular pressure monitoring with the SENSIMED Triggerfish contact lens: effect of body posture during sleep. Issue 10 (7th March 2017)
- Main Title:
- Twenty-four hour intraocular pressure monitoring with the SENSIMED Triggerfish contact lens: effect of body posture during sleep
- Authors:
- Beltran-Agulló, Laura
Buys, Yvonne M
Jahan, Farzana
Shapiro, Colin M
Flanagan, John G
Cheng, Jason
Trope, Graham E - Abstract:
- Abstract : Purpose: To determine the difference in relative intraocular pressure (IOP) measured by the SENSIMED Triggerfish (TF) contact lens in flat compared with 30° head-up sleeping positions in patients with progressive primary open-angle glaucoma or normotensive glaucoma, based on recent or recurrent disc haemorrhage. Design: Prospective, randomised, cross-over, open-label comparative study. Methods: IOP was monitored for 24 hours using TF on two separate sessions. Patients were randomly assigned to sleep flat one night and 30° head-up the other. Outputs in arbitrary units were obtained. Sleep and wake periods were defined as 22:00–6:00 and 8:00–22:00, respectively. Mean TF values during sleep and wake periods and wake–sleep and sleep–wake slopes were calculated for each session. TF output signals were compared between positions. Results: Twelve subjects completed the study. Significant mean positive slopes were noted during the sleep period for both positions (p<0.01). No significant differences in the TF mean values were observed between positions (p=0.51). Six (54%) subjects had mean TF values significantly higher during the flat supine session, while four (36%) subjects had higher values during the head-up session. A significant increase in Goldmann IOP (p=0.001) and TF (p=0.02) measurements were observed after 24 hours of TF wear ('drift phenomenon'). Conclusions: Sleep position affects IOP as measured by TF in some patients with progressive glaucoma. The upwardAbstract : Purpose: To determine the difference in relative intraocular pressure (IOP) measured by the SENSIMED Triggerfish (TF) contact lens in flat compared with 30° head-up sleeping positions in patients with progressive primary open-angle glaucoma or normotensive glaucoma, based on recent or recurrent disc haemorrhage. Design: Prospective, randomised, cross-over, open-label comparative study. Methods: IOP was monitored for 24 hours using TF on two separate sessions. Patients were randomly assigned to sleep flat one night and 30° head-up the other. Outputs in arbitrary units were obtained. Sleep and wake periods were defined as 22:00–6:00 and 8:00–22:00, respectively. Mean TF values during sleep and wake periods and wake–sleep and sleep–wake slopes were calculated for each session. TF output signals were compared between positions. Results: Twelve subjects completed the study. Significant mean positive slopes were noted during the sleep period for both positions (p<0.01). No significant differences in the TF mean values were observed between positions (p=0.51). Six (54%) subjects had mean TF values significantly higher during the flat supine session, while four (36%) subjects had higher values during the head-up session. A significant increase in Goldmann IOP (p=0.001) and TF (p=0.02) measurements were observed after 24 hours of TF wear ('drift phenomenon'). Conclusions: Sleep position affects IOP as measured by TF in some patients with progressive glaucoma. The upward drift in TF output detected in >50% of the subjects requires further investigation to establish whether the increased output values over time are an artefact induced by the TF or a real change in IOP. Trial registration number: NCT01351779 … (more)
- Is Part Of:
- British journal of ophthalmology. Volume 101:Issue 10(2017)
- Journal:
- British journal of ophthalmology
- Issue:
- Volume 101:Issue 10(2017)
- Issue Display:
- Volume 101, Issue 10 (2017)
- Year:
- 2017
- Volume:
- 101
- Issue:
- 10
- Issue Sort Value:
- 2017-0101-0010-0000
- Page Start:
- 1323
- Page End:
- 1328
- Publication Date:
- 2017-03-07
- Subjects:
- Glaucoma -- Optic Nerve -- Diagnostic tests/Investigation -- Contact lens
Ophthalmology -- Periodicals
617.7 - Journal URLs:
- http://bjo.bmj.com/ ↗
http://bjo.bmjjournals.com/ ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/bjophthalmol-2016-308710 ↗
- Languages:
- English
- ISSNs:
- 0007-1161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18089.xml