Clinical outcomes in 995 unselected real-world patients treated with an ultrathin biodegradable polymer-coated sirolimus-eluting stent: 12-month results from the FLEX Registry. Issue 2 (17th February 2016)
- Record Type:
- Journal Article
- Title:
- Clinical outcomes in 995 unselected real-world patients treated with an ultrathin biodegradable polymer-coated sirolimus-eluting stent: 12-month results from the FLEX Registry. Issue 2 (17th February 2016)
- Main Title:
- Clinical outcomes in 995 unselected real-world patients treated with an ultrathin biodegradable polymer-coated sirolimus-eluting stent: 12-month results from the FLEX Registry
- Authors:
- Lemos, Pedro A
Chandwani, Prakash
Saxena, Sudheer
Ramachandran, Padma Kumar
Abhyankar, Atul
Campos, Carlos M
Marchini, Julio Flavio
Galon, Micheli Zanotti
Verma, Puneet
Sandhu, Manjinder Singh
Parikh, Nikhil
Bhupali, Ashok
Jain, Sharad
Prajapati, Jayesh - Abstract:
- Abstract : Objectives: To evaluate, in the FLEX Registry, clinical outcomes of an ultrathin (60 µm) biodegradable polymer-coated Supraflex sirolimus-eluting stent (SES) for the treatment of coronary artery disease. Additionally, to determine the vascular response to the Supraflex SES through optical coherence tomography (OCT) analysis. Setting: Multicentre, single-arm, all-comers, observational registry of patients who were treated with the Supraflex SES, between July 2013 and May 2014, at nine different centres in India. Participants: 995 patients (1242 lesions) who were treated with the Supraflex SES, between July 2013 and May 2014, at nine different centres in India. A total of 47 participants underwent OCT analysis at 6 months' follow-up. Interventions: Percutaneous coronary intervention with Supraflex SES, Primary and secondary outcome measures: The primary endpoint—the rate of major adverse cardiac events (defined as a composite of cardiac death, myocardial infarction (MI), target lesion revascularisation (TLR))—was analysed during 12 months. Results: At 12 months, the primary endpoint occurred in 36 (3.7%) of 980 patients, consisting of 18 (1.8%) cardiac deaths, 16 (1.6%) MI, 7 (0.7%) TLR and 2 (0.2%) cases of non-target lesion target vessel revascularization. In a subset of 47 patients, 1227 cross-sections (9309 struts) were analysed at 6 months by OCT. Overall, a high percentage of struts was covered (98.1%), with a mean neointimal thickness of 0.13±0.06 µm.Abstract : Objectives: To evaluate, in the FLEX Registry, clinical outcomes of an ultrathin (60 µm) biodegradable polymer-coated Supraflex sirolimus-eluting stent (SES) for the treatment of coronary artery disease. Additionally, to determine the vascular response to the Supraflex SES through optical coherence tomography (OCT) analysis. Setting: Multicentre, single-arm, all-comers, observational registry of patients who were treated with the Supraflex SES, between July 2013 and May 2014, at nine different centres in India. Participants: 995 patients (1242 lesions) who were treated with the Supraflex SES, between July 2013 and May 2014, at nine different centres in India. A total of 47 participants underwent OCT analysis at 6 months' follow-up. Interventions: Percutaneous coronary intervention with Supraflex SES, Primary and secondary outcome measures: The primary endpoint—the rate of major adverse cardiac events (defined as a composite of cardiac death, myocardial infarction (MI), target lesion revascularisation (TLR))—was analysed during 12 months. Results: At 12 months, the primary endpoint occurred in 36 (3.7%) of 980 patients, consisting of 18 (1.8%) cardiac deaths, 16 (1.6%) MI, 7 (0.7%) TLR and 2 (0.2%) cases of non-target lesion target vessel revascularization. In a subset of 47 patients, 1227 cross-sections (9309 struts) were analysed at 6 months by OCT. Overall, a high percentage of struts was covered (98.1%), with a mean neointimal thickness of 0.13±0.06 µm. Conclusions: The FLEX Registry evaluated clinical outcomes in real-world and more complex cohorts and thus provides evidence that the Supraflex SEX can be used safely and routinely in a broader percutaneous coronary intervention population. Also, the Supraflex SES showed high percentage of stent strut coverage and good stent apposition during OCT follow-up. … (more)
- Is Part Of:
- BMJ open. Volume 6:Issue 2(2016)
- Journal:
- BMJ open
- Issue:
- Volume 6:Issue 2(2016)
- Issue Display:
- Volume 6, Issue 2 (2016)
- Year:
- 2016
- Volume:
- 6
- Issue:
- 2
- Issue Sort Value:
- 2016-0006-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-02-17
- Subjects:
- Medicine -- Research -- Periodicals
610.72 - Journal URLs:
- http://www.bmj.com/archive ↗
http://bmjopen.bmj.com/ ↗ - DOI:
- 10.1136/bmjopen-2015-010028 ↗
- Languages:
- English
- ISSNs:
- 2044-6055
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18103.xml