A reliability study of colour-Doppler sonography for the diagnosis of chronic cerebrospinal venous insufficiency shows low inter-rater agreement. Issue 11 (15th November 2013)
- Record Type:
- Journal Article
- Title:
- A reliability study of colour-Doppler sonography for the diagnosis of chronic cerebrospinal venous insufficiency shows low inter-rater agreement. Issue 11 (15th November 2013)
- Main Title:
- A reliability study of colour-Doppler sonography for the diagnosis of chronic cerebrospinal venous insufficiency shows low inter-rater agreement
- Authors:
- Leone, Maurizio A
Raymkulova, Olga
Lucenti, Ausiliatrice
Stecco, Alessandro
Bolamperti, Laura
Coppo, Lorenzo
Liboni, William
Rivadossi, Gianandrea
Zaccala, Giuseppe
Maggio, Maurizio
Melis, Fabio
Giaccone, Claudia
Carriero, Alessandro
Lochner, Piergiorgio - Abstract:
- Abstract : Objective: Chronic cerebrospinal venous insufficiency (CCSVI) has been extremely variable, associated with multiple sclerosis in colour-Doppler sonographic studies. We aimed to evaluate inter-rater agreement in a colour-Doppler sonography venous examination. Design: Inter-rater agreement study. Setting: First-referral multiple sclerosis centre. Participants: 38 patients with multiple sclerosis and 55 age-matched (±5 years) controls. Intervention: Sonography was carried out in accordance with Zamboni's five criteria by eight sonographers with different expertise, blinded to the status of cases and controls. Each participant was evaluated by two operators. Primary and secondary outcome measures: Inter-rater agreement was measured through the κ statistics and the intraclass correlation coefficient. Results: The agreement was no higher than chance for criterion 2—reflux in the deep cerebral veins (κ=−0.02) and criterion 4—flow not Doppler detectable in one or both the internal jugular veins (IJVs) or vertebral veins (VVs; −0.09). It was substantially low for criterion 1—reflux in the IJVs and/or VVs (0.29), criterion 3—IJV stenosis or malformations (0.23) and criterion 5—absence of IJV diameter increase when passing from the sitting to the supine position (0.22). The κ value for CCSVI as a whole was 0.20 (95% confidence limit −0.01 to 0.42). Intraclass correlation coefficients for the measure of cross-sectional area ranged from 0.05 to 0.25. Inter-rater agreement wasAbstract : Objective: Chronic cerebrospinal venous insufficiency (CCSVI) has been extremely variable, associated with multiple sclerosis in colour-Doppler sonographic studies. We aimed to evaluate inter-rater agreement in a colour-Doppler sonography venous examination. Design: Inter-rater agreement study. Setting: First-referral multiple sclerosis centre. Participants: 38 patients with multiple sclerosis and 55 age-matched (±5 years) controls. Intervention: Sonography was carried out in accordance with Zamboni's five criteria by eight sonographers with different expertise, blinded to the status of cases and controls. Each participant was evaluated by two operators. Primary and secondary outcome measures: Inter-rater agreement was measured through the κ statistics and the intraclass correlation coefficient. Results: The agreement was no higher than chance for criterion 2—reflux in the deep cerebral veins (κ=−0.02) and criterion 4—flow not Doppler detectable in one or both the internal jugular veins (IJVs) or vertebral veins (VVs; −0.09). It was substantially low for criterion 1—reflux in the IJVs and/or VVs (0.29), criterion 3—IJV stenosis or malformations (0.23) and criterion 5—absence of IJV diameter increase when passing from the sitting to the supine position (0.22). The κ value for CCSVI as a whole was 0.20 (95% confidence limit −0.01 to 0.42). Intraclass correlation coefficients for the measure of cross-sectional area ranged from 0.05 to 0.25. Inter-rater agreement was low for CCSVI experts (κ=0.24; −0.11 to 0.59) and non-experts (0.20; −0.33 to 0.73); neurologists (0.21; −0.06 to 0.47) and non-neurologists (0.18; −0.20 to 0.56); cases (0.19; −0.14 to 0.52) and controls (0.21; −0.08 to 0.49). Zamboni-trained neurosonographers ascertained CCSVI more frequently than the non-trained neurosonographers. Conclusions: Agreement was unsatisfactory for the diagnosis of CCSVI as a whole, for each of its five criteria and according to the different subgroups. Standardisation of the method is urgently needed prior to its further application in studies of patients with multiple sclerosis or other neurological diseases. … (more)
- Is Part Of:
- BMJ open. Volume 3:Issue 11(2013)
- Journal:
- BMJ open
- Issue:
- Volume 3:Issue 11(2013)
- Issue Display:
- Volume 3, Issue 11 (2013)
- Year:
- 2013
- Volume:
- 3
- Issue:
- 11
- Issue Sort Value:
- 2013-0003-0011-0000
- Page Start:
- Page End:
- Publication Date:
- 2013-11-15
- Subjects:
- Medicine -- Research -- Periodicals
610.72 - Journal URLs:
- http://www.bmj.com/archive ↗
http://bmjopen.bmj.com/ ↗ - DOI:
- 10.1136/bmjopen-2013-003508 ↗
- Languages:
- English
- ISSNs:
- 2044-6055
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18126.xml