Major reductions in unnecessary aspartate aminotransferase and blood urea nitrogen tests with a quality improvement initiative. Issue 10 (9th May 2019)
- Record Type:
- Journal Article
- Title:
- Major reductions in unnecessary aspartate aminotransferase and blood urea nitrogen tests with a quality improvement initiative. Issue 10 (9th May 2019)
- Main Title:
- Major reductions in unnecessary aspartate aminotransferase and blood urea nitrogen tests with a quality improvement initiative
- Authors:
- Strauss, Rachel
Cressman, Alex
Cheung, Mark
Weinerman, Adina
Waldman, Suzanne
Etchells, Edward
Zahirieh, Alireza
Tartaro, Piero
Rezmovitz, Jeremy
Callum, Jeannie - Abstract:
- Abstract : Background/context: Unnecessary laboratory testing leads to considerable healthcare costs. Aspartate aminotransferase (AST), commonly ordered with alanine aminotransferase (ALT) and blood urea nitrogen (BUN), commonly ordered with creatinine (Cr), often add little value to patient management at significant cost. We undertook a choosing wisely based quality improvement initiative to reduce the frequency of testing. Objectives: To reduce the ratio of AST/ALT and BUN/Cr to less than 5% for all inpatient and outpatient test orders. Measures: Absolute number and ratio of AST/ALT and BUN/Cr; AST, ALT, BUN and Cr tests per 100 hospital days; projected annualised cost savings and monthly acute inpatient bed days. Improvements: We created guidelines for appropriate indications of AST and BUN testing, provided education with audit and feedback and removed AST and BUN from institutional order sets. Impact/results: The ratios of AST/ALT and BUN/Cr decreased significantly over the study period (0.37 to 0.14, 0.57 to 0.14, respectively), although the goal of 0.05 was not achieved due to a delay in adopting the choosing wisely strategies during the study time period by some inpatient units. The number of tests per 100 hospital days decreased from 20 to 7 AST (95% CI 19 to 20.5, 5.6 to 8.7, p<0.001) and from 72 to 17 BUN (95% CI 70 to 73.4, 16.6 to 22.9, p<0.001). The initiative resulted in a projected annualised cost savings of C$221 749. Discussion: A significant decrease inAbstract : Background/context: Unnecessary laboratory testing leads to considerable healthcare costs. Aspartate aminotransferase (AST), commonly ordered with alanine aminotransferase (ALT) and blood urea nitrogen (BUN), commonly ordered with creatinine (Cr), often add little value to patient management at significant cost. We undertook a choosing wisely based quality improvement initiative to reduce the frequency of testing. Objectives: To reduce the ratio of AST/ALT and BUN/Cr to less than 5% for all inpatient and outpatient test orders. Measures: Absolute number and ratio of AST/ALT and BUN/Cr; AST, ALT, BUN and Cr tests per 100 hospital days; projected annualised cost savings and monthly acute inpatient bed days. Improvements: We created guidelines for appropriate indications of AST and BUN testing, provided education with audit and feedback and removed AST and BUN from institutional order sets. Impact/results: The ratios of AST/ALT and BUN/Cr decreased significantly over the study period (0.37 to 0.14, 0.57 to 0.14, respectively), although the goal of 0.05 was not achieved due to a delay in adopting the choosing wisely strategies during the study time period by some inpatient units. The number of tests per 100 hospital days decreased from 20 to 7 AST (95% CI 19 to 20.5, 5.6 to 8.7, p<0.001) and from 72 to 17 BUN (95% CI 70 to 73.4, 16.6 to 22.9, p<0.001). The initiative resulted in a projected annualised cost savings of C$221 749. Discussion: A significant decrease in the AST/ALT and BUN/Cr ratios can be achieved with a multimodal approach and will result in substantial healthcare savings. … (more)
- Is Part Of:
- BMJ quality & safety. Volume 28:Issue 10(2019)
- Journal:
- BMJ quality & safety
- Issue:
- Volume 28:Issue 10(2019)
- Issue Display:
- Volume 28, Issue 10 (2019)
- Year:
- 2019
- Volume:
- 28
- Issue:
- 10
- Issue Sort Value:
- 2019-0028-0010-0000
- Page Start:
- 809
- Page End:
- 816
- Publication Date:
- 2019-05-09
- Subjects:
- quality improvement -- laboratory medicine -- educational outreach, academic detialing
Medical care -- Quality control -- Periodicals
Health facilities -- Risk management -- Periodicals
Medical errors -- Prevention -- Periodicals
362.106805 - Journal URLs:
- http://www.bmj.com/archive ↗
http://qualitysafety.bmj.com/ ↗ - DOI:
- 10.1136/bmjqs-2018-008991 ↗
- Languages:
- English
- ISSNs:
- 2044-5415
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 18076.xml