212 IN VIVO STRAIN GAUGE ATTACHMENT TO MOUSE FEMORA. (1st January 2006)
- Record Type:
- Journal Article
- Title:
- 212 IN VIVO STRAIN GAUGE ATTACHMENT TO MOUSE FEMORA. (1st January 2006)
- Main Title:
- 212 IN VIVO STRAIN GAUGE ATTACHMENT TO MOUSE FEMORA.
- Authors:
- Margolis, D. S.
Pennington, D.
Szivek, J. A.
Grana, W. A.
Furenlid, L.
Wilson, D.
Lia, L. W.
Lien, Y. H. - Abstract:
- Abstract : Bone properties are dynamic and change due to physiologic strains generated during loading. Measurement of physiologic strains has been accomplished in dogs and rats with the use calcium phosphate ceramic (CPC) coated strain gauges. The purpose of this study was to determine whether TGF-β1 enhanced CPC coated strain gauges could be attached to mouse femora in vivo. Five mice were implanted with CPC-2 coated uniaxial, single element strain gauges (Vishay Micro measurements, NC) that were enhanced with 0.25 μg of TGF-β1 8 hours before surgery. One strain gauge was implanted in each mouse, and the gauges were initially secured to the right femur of each mouse using 2 resorbable sutures. The mice were sacrifice 8 weeks postop. Following sacrifice the mechanical attachment of the implanted gauges was measured using a cantilever bend test. The bone bonding and bone to CPC contact was evaluated using high resolution μCT and histology. Bone formation rate was measured using CT/SPECT imaging and histomorphometry. Cantilever bend testing indicated that strain transfer through the CPC coated gauges was 51 ± 16% of strain measured in a control gauge glued to the contralateral femora. High resolution μCT and histology demonstrated extensive contact between the bone and CPC particles. Although there was an increased amount of bone in the experimental femora, this did not result in a significant increase in bone volume (46±6% in experimental femora and 47 ± 4% in controlAbstract : Bone properties are dynamic and change due to physiologic strains generated during loading. Measurement of physiologic strains has been accomplished in dogs and rats with the use calcium phosphate ceramic (CPC) coated strain gauges. The purpose of this study was to determine whether TGF-β1 enhanced CPC coated strain gauges could be attached to mouse femora in vivo. Five mice were implanted with CPC-2 coated uniaxial, single element strain gauges (Vishay Micro measurements, NC) that were enhanced with 0.25 μg of TGF-β1 8 hours before surgery. One strain gauge was implanted in each mouse, and the gauges were initially secured to the right femur of each mouse using 2 resorbable sutures. The mice were sacrifice 8 weeks postop. Following sacrifice the mechanical attachment of the implanted gauges was measured using a cantilever bend test. The bone bonding and bone to CPC contact was evaluated using high resolution μCT and histology. Bone formation rate was measured using CT/SPECT imaging and histomorphometry. Cantilever bend testing indicated that strain transfer through the CPC coated gauges was 51 ± 16% of strain measured in a control gauge glued to the contralateral femora. High resolution μCT and histology demonstrated extensive contact between the bone and CPC particles. Although there was an increased amount of bone in the experimental femora, this did not result in a significant increase in bone volume (46±6% in experimental femora and 47 ± 4% in control femora). SPECT imaging demonstrated increased bone formation on the experimental femur near the implanted sensors. Histomorphometry confirmed the increased BFR (0.0022 ± 0.0011 μm 3 /μm 2 /day in experimental femora and 0.0006 ± 0.0002 μm 3 /μm 2 /day in control femora) and demonstrated that the increase was due to an increased mineral apposition rate (0.0022 ± 0.0007 μm/day in experimental femora and 0.0010 ± 0.0002 μm/day in control femora). These results indicate extensive bone to CPC bonding occurs in mice implanted with CPC coated strain gauges. The use of in vivo bone strain gauging will be a valuable tool to study strain mediated bone remodeling in mice. In addition this technique allows for investigation of the magnitudes and roles of physiologic bone strains generated in gene knockout mice. … (more)
- Is Part Of:
- Journal of investigative medicine. Volume 54:Number 1(2006)
- Journal:
- Journal of investigative medicine
- Issue:
- Volume 54:Number 1(2006)
- Issue Display:
- Volume 54, Issue 1 (2006)
- Year:
- 2006
- Volume:
- 54
- Issue:
- 1
- Issue Sort Value:
- 2006-0054-0001-0000
- Page Start:
- S116
- Page End:
- S116
- Publication Date:
- 2006-01-01
- Subjects:
- Clinical medicine -- Periodicals
Medicine -- Research -- Periodicals
Medicine
Research -- United States
Clinical medicine
Medicine -- Research
Periodicals
616.075 - Journal URLs:
- http://journals.lww.com/jinvestigativemed/pages/default.aspx ↗
http://jim.bmj.com/ ↗
https://journals.sagepub.com/home/IMJ ↗
http://journals.lww.com ↗ - DOI:
- 10.2310/6650.2005.X0004.211 ↗
- Languages:
- English
- ISSNs:
- 1081-5589
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5008.010000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 18073.xml