Determination of serum IgG antibodies to Bacillus anthracis protective antigen in environmental sampling workers using a fluorescent covalent microsphere immunoassay. Issue 8 (16th July 2004)
- Record Type:
- Journal Article
- Title:
- Determination of serum IgG antibodies to Bacillus anthracis protective antigen in environmental sampling workers using a fluorescent covalent microsphere immunoassay. Issue 8 (16th July 2004)
- Main Title:
- Determination of serum IgG antibodies to Bacillus anthracis protective antigen in environmental sampling workers using a fluorescent covalent microsphere immunoassay
- Authors:
- Biagini, R E
Sammons, D L
Smith, J P
Page, E H
Snawder, J E
Striley, C A F
MacKenzie, B A - Abstract:
- Abstract : Aims: To evaluate potential exposure to Bacillis anthracis ( Ba ) spores in sampling/decontamination workers in the aftermath of an anthrax terror attack. Methods: Fifty six serum samples were obtained from workers involved in environmental sampling for Ba spores at the American Media, Inc. (AMI) building in Boca Raton, FL after the anthrax attack there in October 2001. Nineteen sera were drawn from individuals both pre-entry and several weeks after entrance into the building. Nine sera each were drawn from unique individuals at the pre-entry and follow up blood draws. Thirteen donor control sera were also evaluated. Individuals were surveyed for Ba exposure by measurement of serum Ba anti-protective antigen (PA) specific IgG antibodies using a newly developed fluorescent covalent microsphere immunoassay (FCMIA). Results: Four sera gave positive anti-PA IgG results (defined as anti-PA IgG concentrations ⩾ the mean μg/ml anti-PA IgG from donor control sera (n = 13 plus 2 SD which were also inhibited ⩾ 85% when the serum was pre-adsorbed with PA). The positive sera were the pre-entry and follow up samples of two workers who had received their last dose of anthrax vaccine in 2000. Conclusion: It appears that the sampling/decontamination workers of the present study either had insufficient exposure to Ba spores to cause the production of anti-PA IgG antibodies or they were exposed to anthrax spores without producing antibody. The FCMIA appears to be a fast, sensitive,Abstract : Aims: To evaluate potential exposure to Bacillis anthracis ( Ba ) spores in sampling/decontamination workers in the aftermath of an anthrax terror attack. Methods: Fifty six serum samples were obtained from workers involved in environmental sampling for Ba spores at the American Media, Inc. (AMI) building in Boca Raton, FL after the anthrax attack there in October 2001. Nineteen sera were drawn from individuals both pre-entry and several weeks after entrance into the building. Nine sera each were drawn from unique individuals at the pre-entry and follow up blood draws. Thirteen donor control sera were also evaluated. Individuals were surveyed for Ba exposure by measurement of serum Ba anti-protective antigen (PA) specific IgG antibodies using a newly developed fluorescent covalent microsphere immunoassay (FCMIA). Results: Four sera gave positive anti-PA IgG results (defined as anti-PA IgG concentrations ⩾ the mean μg/ml anti-PA IgG from donor control sera (n = 13 plus 2 SD which were also inhibited ⩾ 85% when the serum was pre-adsorbed with PA). The positive sera were the pre-entry and follow up samples of two workers who had received their last dose of anthrax vaccine in 2000. Conclusion: It appears that the sampling/decontamination workers of the present study either had insufficient exposure to Ba spores to cause the production of anti-PA IgG antibodies or they were exposed to anthrax spores without producing antibody. The FCMIA appears to be a fast, sensitive, accurate, and precise method for the measurement of anti-PA IgG antibodies. … (more)
- Is Part Of:
- Occupational and environmental medicine. Volume 61:Issue 8(2004)
- Journal:
- Occupational and environmental medicine
- Issue:
- Volume 61:Issue 8(2004)
- Issue Display:
- Volume 61, Issue 8 (2004)
- Year:
- 2004
- Volume:
- 61
- Issue:
- 8
- Issue Sort Value:
- 2004-0061-0008-0000
- Page Start:
- 703
- Page End:
- 708
- Publication Date:
- 2004-07-16
- Subjects:
- AMI, American Media, Inc -- AVA, anthrax vaccine adsorbed -- Ba, Bacillus anthracis -- FCMIA, fluorescent covalent microsphere immunoassay -- MDC, minimum detectable concentration -- MFI, median fluorescence intensity -- PA, protective antigen -- PPE, personal protective equipment -- RDL, reliable detection limit
anthrax protective antigen -- decontamination workers -- ELISA -- Luminex
Medicine, Industrial -- Periodicals
Environmental health -- Periodicals
616.980305 - Journal URLs:
- http://oem.bmj.com/ ↗
http://www.jstor.org/journals/13510711.html ↗
http://www.pubmedcentral.nih.gov/tocrender.fcgi?journal=172&action=archive ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/oem.2003.008565 ↗
- Languages:
- English
- ISSNs:
- 1351-0711
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18057.xml