Amide proton transfer‐weighted imaging to differentiate malignant from benign pulmonary lesions: Comparison with diffusion‐weighted imaging and FDG‐PET/CT. Issue 4 (11th August 2017)
- Record Type:
- Journal Article
- Title:
- Amide proton transfer‐weighted imaging to differentiate malignant from benign pulmonary lesions: Comparison with diffusion‐weighted imaging and FDG‐PET/CT. Issue 4 (11th August 2017)
- Main Title:
- Amide proton transfer‐weighted imaging to differentiate malignant from benign pulmonary lesions: Comparison with diffusion‐weighted imaging and FDG‐PET/CT
- Authors:
- Ohno, Yoshiharu
Kishida, Yuji
Seki, Shinichiro
Yui, Masao
Miyazaki, Mitsue
Koyama, Hisanobu
Yoshikawa, Takeshi - Abstract:
- Abstract : Purpose: To compare the capability of amide proton transfer‐weighted (APTw) imaging, diffusion‐weighted imaging (DWI), and FDG‐PET/CT for the differentiation of malignant from benign pulmonary nodules. Materials and Methods: In all, 82 consecutive patients with pulmonary nodules underwent APTw imaging and DWI with a 3T system, and FDG‐PET/CT. All nodules were divided as either malignant ( n = 49) or benign ( n = 39) groups based on pathological and follow‐up examinations. To evaluate the capability for differentiation of malignant from benign nodules, magnetization transfer ratio asymmetry (MTRasym )(3.5ppm) on APTw imaging, apparent diffusion coefficient (ADC), and maximum value of standard uptake value (SUVmax ) were assessed. Receiver operating characteristic (ROC) analyses were performed to computationally determine each feasible threshold value. Next, McNemar's test was used for comparing diagnostic performance with each other as well as with a combination of the significant factors determined by multivariate logistic regression analysis. Results: Although sensitivity of ADC was significantly higher than that of MTRasym (3.5 ppm) ( P = 0.002) and SUVmax ( P = 0.004), specificity of MTRasym (3.5 ppm) and SUVmax was significantly higher than that of ADC ( P < 0.05). Sensitivity of combined MTRasym (3.5ppm) with SUVmax was significantly higher than that of MTRasym (3.5ppm) ( P = 0.001) and SUVmax ( P = 0.002) alone. Moreover, specificity and accuracy of combinedAbstract : Purpose: To compare the capability of amide proton transfer‐weighted (APTw) imaging, diffusion‐weighted imaging (DWI), and FDG‐PET/CT for the differentiation of malignant from benign pulmonary nodules. Materials and Methods: In all, 82 consecutive patients with pulmonary nodules underwent APTw imaging and DWI with a 3T system, and FDG‐PET/CT. All nodules were divided as either malignant ( n = 49) or benign ( n = 39) groups based on pathological and follow‐up examinations. To evaluate the capability for differentiation of malignant from benign nodules, magnetization transfer ratio asymmetry (MTRasym )(3.5ppm) on APTw imaging, apparent diffusion coefficient (ADC), and maximum value of standard uptake value (SUVmax ) were assessed. Receiver operating characteristic (ROC) analyses were performed to computationally determine each feasible threshold value. Next, McNemar's test was used for comparing diagnostic performance with each other as well as with a combination of the significant factors determined by multivariate logistic regression analysis. Results: Although sensitivity of ADC was significantly higher than that of MTRasym (3.5 ppm) ( P = 0.002) and SUVmax ( P = 0.004), specificity of MTRasym (3.5 ppm) and SUVmax was significantly higher than that of ADC ( P < 0.05). Sensitivity of combined MTRasym (3.5ppm) with SUVmax was significantly higher than that of MTRasym (3.5ppm) ( P = 0.001) and SUVmax ( P = 0.002) alone. Moreover, specificity and accuracy of combined MTRasym (3.5ppm) with SUVmax were significantly higher than that of ADC (specificity: P = 0.002, accuracy: P = 0.008). Conclusion: APTw imaging appears to be as useful as DWI and FDG‐PET/CT for differentiation of malignant from benign nodules. Level of Evidence: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:1013–1021. … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 47:Issue 4(2018)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 47:Issue 4(2018)
- Issue Display:
- Volume 47, Issue 4 (2018)
- Year:
- 2018
- Volume:
- 47
- Issue:
- 4
- Issue Sort Value:
- 2018-0047-0004-0000
- Page Start:
- 1013
- Page End:
- 1021
- Publication Date:
- 2017-08-11
- Subjects:
- lung nodule -- MR imaging -- chemical exchange saturation transfer -- lung cancer
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.25832 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18051.xml