Simple method for computing scattered radiation in breast tomosynthesis. Issue 11 (9th September 2019)
- Record Type:
- Journal Article
- Title:
- Simple method for computing scattered radiation in breast tomosynthesis. Issue 11 (9th September 2019)
- Main Title:
- Simple method for computing scattered radiation in breast tomosynthesis
- Authors:
- Diaz, Oliver
Elangovan, Premkumar
Young, Kenneth C.
Wells, Kevin
Dance, David R. - Abstract:
- Abstract : Purpose: Virtual clinical trials (VCT) are a powerful imaging tool that can be used to investigate digital breast tomosynthesis (DBT) technology. In this work, a fast and simple method is proposed to estimate the two‐dimensional distribution of scattered radiation which is needed when simulating DBT geometries in VCTs. Methods: Monte Carlo simulations are used to precalculate scatter‐to‐primary ratio (SPR) for a range of low‐resolution homogeneous phantoms. The resulting values can be used to estimate the two‐dimensional (2D) distribution of scattered radiation arising from inhomogeneous anthropomorphic phantoms used in VCTs. The method has been validated by comparing the values of the scatter thus obtained against the results of direct Monte Carlo simulation for three different types of inhomogeneous anthropomorphic phantoms. Results: Differences between the proposed scatter field estimation method and the ground truth data for the OPTIMAM phantom had an average modulus and standard deviation of over the projected breast area of 2.4 ± 0.9% (minimum −17.0%, maximum 27.7%). The corresponding values for the University of Pennsylvania and Duke University breast phantoms were 1.8 ± 0.1% (minimum −8.7%, maximum 8.0%) and 5.1 ± 0.1% (minimum −16.2%, maximum 7.4%), respectively. Conclusions: The proposed method, which has been validated using three of the most common breast models, is a useful tool for accurately estimating scattered radiation in VCT schemes used toAbstract : Purpose: Virtual clinical trials (VCT) are a powerful imaging tool that can be used to investigate digital breast tomosynthesis (DBT) technology. In this work, a fast and simple method is proposed to estimate the two‐dimensional distribution of scattered radiation which is needed when simulating DBT geometries in VCTs. Methods: Monte Carlo simulations are used to precalculate scatter‐to‐primary ratio (SPR) for a range of low‐resolution homogeneous phantoms. The resulting values can be used to estimate the two‐dimensional (2D) distribution of scattered radiation arising from inhomogeneous anthropomorphic phantoms used in VCTs. The method has been validated by comparing the values of the scatter thus obtained against the results of direct Monte Carlo simulation for three different types of inhomogeneous anthropomorphic phantoms. Results: Differences between the proposed scatter field estimation method and the ground truth data for the OPTIMAM phantom had an average modulus and standard deviation of over the projected breast area of 2.4 ± 0.9% (minimum −17.0%, maximum 27.7%). The corresponding values for the University of Pennsylvania and Duke University breast phantoms were 1.8 ± 0.1% (minimum −8.7%, maximum 8.0%) and 5.1 ± 0.1% (minimum −16.2%, maximum 7.4%), respectively. Conclusions: The proposed method, which has been validated using three of the most common breast models, is a useful tool for accurately estimating scattered radiation in VCT schemes used to study current designs of DBT system. … (more)
- Is Part Of:
- Medical physics. Volume 46:Issue 11(2019)
- Journal:
- Medical physics
- Issue:
- Volume 46:Issue 11(2019)
- Issue Display:
- Volume 46, Issue 11 (2019)
- Year:
- 2019
- Volume:
- 46
- Issue:
- 11
- Issue Sort Value:
- 2019-0046-0011-0000
- Page Start:
- 4826
- Page End:
- 4836
- Publication Date:
- 2019-09-09
- Subjects:
- anthropomorphic breast models -- DBT -- Monte Carlo simulations -- scattered radiation -- SPR -- virtual clinical trial
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.13760 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18049.xml