Technical Note: A fast inverse direct aperture optimization algorithm for volumetric‐modulated arc therapy. Issue 4 (1st March 2020)
- Record Type:
- Journal Article
- Title:
- Technical Note: A fast inverse direct aperture optimization algorithm for volumetric‐modulated arc therapy. Issue 4 (1st March 2020)
- Main Title:
- Technical Note: A fast inverse direct aperture optimization algorithm for volumetric‐modulated arc therapy
- Authors:
- MacFarlane, Michael
Hoover, Douglas A.
Wong, Eugene
Battista, Jerry J.
Chen, Jeff Z. - Abstract:
- Abstract : Purpose: In a recent article, our group proposed a fast direct aperture optimization (DAO) algorithm for fixed‐gantry intensity‐modulated radiation therapy (IMRT) called fast inverse direct aperture optimization (FIDAO). When tested on fixed‐gantry IMRT plans, we observed up to a 200‐fold increase in the optimization speed. Compared to IMRT, rotational volumetric‐modulated arc therapy (VMAT) is a much larger optimization problem and has many more delivery constraints. The purpose of this work is to extend and evaluate FIDAO for inverse planning of VMAT plans. Methods: A prototype FIDAO algorithm for VMAT treatment planning was developed in MATLAB using the open‐source treatment planning toolkit matRad (v2.2 dev_VMAT build). VMAT treatment plans using one 360 0 arc were generated on the AAPM TG‐119 phantom, as well as sample clinical liver and prostate cases. The plans were created by first performing fluence map optimization on 28° equispaced beams, followed by aperture sequencing and arc sequencing with a gantry angular sampling rate of 4°. After arc sequencing, a copy of the plan underwent DAO using the prototype FIDAO algorithm, while another copy of the plan underwent DAO using matRad's DAO method, which served as the conventional algorithm. Results: Both algorithms achieved similar plan quality, although the FIDAO plans had considerably fewer hot spots in the unspecified normal tissue. The optimization time (number of iterations) for FIDAO and theAbstract : Purpose: In a recent article, our group proposed a fast direct aperture optimization (DAO) algorithm for fixed‐gantry intensity‐modulated radiation therapy (IMRT) called fast inverse direct aperture optimization (FIDAO). When tested on fixed‐gantry IMRT plans, we observed up to a 200‐fold increase in the optimization speed. Compared to IMRT, rotational volumetric‐modulated arc therapy (VMAT) is a much larger optimization problem and has many more delivery constraints. The purpose of this work is to extend and evaluate FIDAO for inverse planning of VMAT plans. Methods: A prototype FIDAO algorithm for VMAT treatment planning was developed in MATLAB using the open‐source treatment planning toolkit matRad (v2.2 dev_VMAT build). VMAT treatment plans using one 360 0 arc were generated on the AAPM TG‐119 phantom, as well as sample clinical liver and prostate cases. The plans were created by first performing fluence map optimization on 28° equispaced beams, followed by aperture sequencing and arc sequencing with a gantry angular sampling rate of 4°. After arc sequencing, a copy of the plan underwent DAO using the prototype FIDAO algorithm, while another copy of the plan underwent DAO using matRad's DAO method, which served as the conventional algorithm. Results: Both algorithms achieved similar plan quality, although the FIDAO plans had considerably fewer hot spots in the unspecified normal tissue. The optimization time (number of iterations) for FIDAO and the conventional DAO algorithm, respectively, were: 65 s (245) vs 602 s (275) in the TG‐119 phantom case; 25 s (85) vs 803 s (159) in the liver case; and 99 s (174) vs 754 s (149) in the prostate case. Conclusions: This study demonstrated promising speed enhancements in using FIDAO for the direct aperture optimization of VMAT plans. … (more)
- Is Part Of:
- Medical physics. Volume 47:Issue 4(2020)
- Journal:
- Medical physics
- Issue:
- Volume 47:Issue 4(2020)
- Issue Display:
- Volume 47, Issue 4 (2020)
- Year:
- 2020
- Volume:
- 47
- Issue:
- 4
- Issue Sort Value:
- 2020-0047-0004-0000
- Page Start:
- 1558
- Page End:
- 1565
- Publication Date:
- 2020-03-01
- Subjects:
- direct aperture optimization (DAO) -- fast inverse direct aperture optimization (FIDAO) -- fast inverse dose optimization (FIDO) -- volume modulated radiation therapy (VMAT)
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.14074 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18072.xml