Real‐time 4DMRI‐based internal target volume definition for moving lung tumors. Issue 4 (10th February 2020)
- Record Type:
- Journal Article
- Title:
- Real‐time 4DMRI‐based internal target volume definition for moving lung tumors. Issue 4 (10th February 2020)
- Main Title:
- Real‐time 4DMRI‐based internal target volume definition for moving lung tumors
- Authors:
- Rabe, Moritz
Thieke, Christian
Düsberg, Mathias
Neppl, Sebastian
Gerum, Sabine
Reiner, Michael
Nicolay, Nils Henrik
Schlemmer, Heinz‐Peter
Debus, Jürgen
Dinkel, Julien
Landry, Guillaume
Parodi, Katia
Belka, Claus
Kurz, Christopher
Kamp, Florian - Abstract:
- Abstract : Purpose: In photon radiotherapy, respiratory‐induced target motion can be accounted for by internal target volumes (ITV) or mid‐ventilation target volumes (midV) defined on the basis of four‐dimensional computed tomography (4D‐CT). Intrinsic limitations of these approaches can result in target volumes that are not representative for the gross tumor volume (GTV) motion over the course of treatment. To address these limitations, we propose a novel patient‐specific ITV definition method based on real‐time 4D magnetic resonance imaging (rt‐4DMRI). Methods: Three lung cancer patients underwent weekly rt‐4DMRI scans. A total of 24 datasets were included in this retrospective study. The GTV was contoured on breath‐hold MR images and propagated to all rt‐4DMRI images by deformable image registration. Different targets were created for the first (reference) imaging sessions: ITVs encompassing all GTV positions over the complete (ITV 80 s ) or partial acquisition time ( ITV 10 s ), ITVs including only voxels with a GTV probability‐of‐presence (POP) of at least 5% ( ITV 5 % ) or 10% ( ITV 10 % ), and the mid‐ventilation GTV position. Reference planning target volumes ( PTV r ) were created by adding margins around the ITVs and midV target volumes. The geometrical overlap of the PTV r with ITV n 5 % from the six to eight subsequent imaging sessions on days n was quantified in terms of the Dice similarity coefficient (DSC), sensitivity [SE: ( PTV r ∩ ITV n 5 % )/ ITV n 5 % ]Abstract : Purpose: In photon radiotherapy, respiratory‐induced target motion can be accounted for by internal target volumes (ITV) or mid‐ventilation target volumes (midV) defined on the basis of four‐dimensional computed tomography (4D‐CT). Intrinsic limitations of these approaches can result in target volumes that are not representative for the gross tumor volume (GTV) motion over the course of treatment. To address these limitations, we propose a novel patient‐specific ITV definition method based on real‐time 4D magnetic resonance imaging (rt‐4DMRI). Methods: Three lung cancer patients underwent weekly rt‐4DMRI scans. A total of 24 datasets were included in this retrospective study. The GTV was contoured on breath‐hold MR images and propagated to all rt‐4DMRI images by deformable image registration. Different targets were created for the first (reference) imaging sessions: ITVs encompassing all GTV positions over the complete (ITV 80 s ) or partial acquisition time ( ITV 10 s ), ITVs including only voxels with a GTV probability‐of‐presence (POP) of at least 5% ( ITV 5 % ) or 10% ( ITV 10 % ), and the mid‐ventilation GTV position. Reference planning target volumes ( PTV r ) were created by adding margins around the ITVs and midV target volumes. The geometrical overlap of the PTV r with ITV n 5 % from the six to eight subsequent imaging sessions on days n was quantified in terms of the Dice similarity coefficient (DSC), sensitivity [SE: ( PTV r ∩ ITV n 5 % )/ ITV n 5 % ] and precision [PRE: ( PTV r ∩ ITV n 5 % )/ PTV r ] as surrogates for target coverage and normal tissue sparing. Results: Patient‐specific analysis yielded a high variance of the overlap values of PTV r 10 s, when different periods within the reference imaging session were sampled. The mid‐ventilation‐based PTVs were smaller than the ITV‐based PTVs. While the SE was high for patients with small breathing pattern variations, changes of the median breathing amplitudes in different imaging sessions led to inferior SE values for the mid‐ventilation PTV for one patient. In contrast, PTV r 5 % and PTV r 10 % showed higher SE values with a higher robustness against interfractional changes, at the cost of larger target volumes. Conclusions: The results indicate that rt‐4DMRI could be valuable for the definition of target volumes based on the GTV POP to achieve a higher robustness against interfractional changes than feasible with today's 4D‐CT‐based target definition concepts. … (more)
- Is Part Of:
- Medical physics. Volume 47:Issue 4(2020)
- Journal:
- Medical physics
- Issue:
- Volume 47:Issue 4(2020)
- Issue Display:
- Volume 47, Issue 4 (2020)
- Year:
- 2020
- Volume:
- 47
- Issue:
- 4
- Issue Sort Value:
- 2020-0047-0004-0000
- Page Start:
- 1431
- Page End:
- 1442
- Publication Date:
- 2020-02-10
- Subjects:
- 4DMRI -- interfractional changes -- ITV -- lung tumor -- mid‐ventilation -- motion management
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.14023 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18072.xml