Ennis, Daniel B. - Abstract:
- Abstract : Purpose: The purpose of this study was to develop a neural network that accurately performs diffusion tensor imaging (DTI) reconstruction from highly accelerated scans. Materials and Methods: This retrospective study was conducted using data acquired between 2013 and 2018 and was approved by the local institutional review board. DTI acquired in healthy volunteers (N = 10) was used to train a neural network, DiffNet, to reconstruct fractional anisotropy (FA) and mean diffusivity (MD) maps from small subsets of acquired DTI data with between 3 and 20 diffusion‐encoding directions. FA and MD maps were then reconstructed in volunteers and in patients with glioblastoma multiforme (GBM, N = 12) using both DiffNet and conventional reconstructions. Accuracy and precision were quantified in volunteer scans and compared between reconstructions. The accuracy of tumor delineation was compared between reconstructed patient data by evaluating agreement between DTI‐derived tumor volumes and volumes defined by contrast‐enhanced T1‐weighted MRI. Comparisons were performed using areas under the receiver operating characteristic curves (AUC). Results: DiffNet FA reconstructions were more accurate and precise compared with conventional reconstructions for all acceleration factors. DiffNet permitted reconstruction with only three diffusion‐encoding directions with significantly lower bias than the conventional method using six directions (0.01 ± 0.01 vs 0.06 ± 0.01, P < 0.001). WhileAbstract : Purpose: The purpose of this study was to develop a neural network that accurately performs diffusion tensor imaging (DTI) reconstruction from highly accelerated scans. Materials and Methods: This retrospective study was conducted using data acquired between 2013 and 2018 and was approved by the local institutional review board. DTI acquired in healthy volunteers (N = 10) was used to train a neural network, DiffNet, to reconstruct fractional anisotropy (FA) and mean diffusivity (MD) maps from small subsets of acquired DTI data with between 3 and 20 diffusion‐encoding directions. FA and MD maps were then reconstructed in volunteers and in patients with glioblastoma multiforme (GBM, N = 12) using both DiffNet and conventional reconstructions. Accuracy and precision were quantified in volunteer scans and compared between reconstructions. The accuracy of tumor delineation was compared between reconstructed patient data by evaluating agreement between DTI‐derived tumor volumes and volumes defined by contrast‐enhanced T1‐weighted MRI. Comparisons were performed using areas under the receiver operating characteristic curves (AUC). Results: DiffNet FA reconstructions were more accurate and precise compared with conventional reconstructions for all acceleration factors. DiffNet permitted reconstruction with only three diffusion‐encoding directions with significantly lower bias than the conventional method using six directions (0.01 ± 0.01 vs 0.06 ± 0.01, P < 0.001). While MD‐based tumor delineation was not substantially different with DiffNet (AUC range: 0.888–0.902), DiffNet FA had higher AUC than conventional reconstructions for fixed scan time and achieved similar performance with shorter scans (conventional, six directions: AUC = 0.926, DiffNet, three directions: AUC = 0.920). Conclusion: DiffNet improved DTI reconstruction accuracy, precision, and tumor delineation performance in GBM while permitting reconstruction from only three diffusion‐encoding directions.&!#6; … (more)
- Is Part Of:
- Medical physics. Volume 46:Issue 4(2019)
- Journal:
- Medical physics
- Issue:
- Volume 46:Issue 4(2019)
- Issue Display:
- Volume 46, Issue 4 (2019)
- Year:
- 2019
- Volume:
- 46
- Issue:
- 4
- Issue Sort Value:
- 2019-0046-0004-0000
- Page Start:
- 1581
- Page End:
- 1591
- Publication Date:
- 2019-02-14
- Subjects:
- diffusion MRI -- glioblastoma -- machine learning -- quantitative imaging
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.13400 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18026.xml