Technical Note: Relative proton stopping power estimation from virtual monoenergetic images reconstructed from dual‐layer computed tomography. Issue 4 (19th February 2019)
- Record Type:
- Journal Article
- Title:
- Technical Note: Relative proton stopping power estimation from virtual monoenergetic images reconstructed from dual‐layer computed tomography. Issue 4 (19th February 2019)
- Main Title:
- Technical Note: Relative proton stopping power estimation from virtual monoenergetic images reconstructed from dual‐layer computed tomography
- Authors:
- Landry, Guillaume
Dörringer, Fabian
Si‐Mohamed, Salim
Douek, Philippe
Abascal, Juan F. P. J.
Peyrin, Françoise
Almeida, Isabel P.
Verhaegen, Frank
Rinaldi, Ilaria
Parodi, Katia
Rit, Simon - Abstract:
- Abstract : Purpose: The objective of this technical note was to investigate the accuracy of proton stopping power relative to water (RSP) estimation using a novel dual‐layer, dual‐energy computed tomography (DL‐DECT) scanner for potential use in proton therapy planning. DL‐DECT allows dual‐energy reconstruction from scans acquired at a single x‐ray tube voltage V by using two‐layered detectors. Methods: Sets of calibration and evaluation inserts were scanned at a DL‐DECT scanner in a custom phantom with variable diameter D (0 to 150 mm) at V of 120 and 140 kV. Inserts were additionally scanned at a synchrotron computed tomography facility to obtain comparative linear attenuation coefficients for energies from 50 to 100 keV, and reference RSP was obtained using a carbon ion beam and variable water column. DL‐DECT monoenergetic (mono‐E) reconstructions were employed to obtain RSP by adapting the Yang–Saito–Landry (YSL) method. The method was compared to reference RSP via the root mean square error (RMSE) over insert mean values obtained from volumetric regions of interest. The accuracy of intermediate quantities such as the relative electron density (RED), effective atomic number (EAN), and the mono‐E was additionally evaluated. Results: The lung inserts showed higher errors for all quantities and we report RMSE excluding them. RMSE for μ from DL‐DECT mono‐E was below 1.9%. For the evaluation inserts at D = 150 mm and V = 140 kV, RED RMSE was 1.0%, while for EAN it was 2.9%.Abstract : Purpose: The objective of this technical note was to investigate the accuracy of proton stopping power relative to water (RSP) estimation using a novel dual‐layer, dual‐energy computed tomography (DL‐DECT) scanner for potential use in proton therapy planning. DL‐DECT allows dual‐energy reconstruction from scans acquired at a single x‐ray tube voltage V by using two‐layered detectors. Methods: Sets of calibration and evaluation inserts were scanned at a DL‐DECT scanner in a custom phantom with variable diameter D (0 to 150 mm) at V of 120 and 140 kV. Inserts were additionally scanned at a synchrotron computed tomography facility to obtain comparative linear attenuation coefficients for energies from 50 to 100 keV, and reference RSP was obtained using a carbon ion beam and variable water column. DL‐DECT monoenergetic (mono‐E) reconstructions were employed to obtain RSP by adapting the Yang–Saito–Landry (YSL) method. The method was compared to reference RSP via the root mean square error (RMSE) over insert mean values obtained from volumetric regions of interest. The accuracy of intermediate quantities such as the relative electron density (RED), effective atomic number (EAN), and the mono‐E was additionally evaluated. Results: The lung inserts showed higher errors for all quantities and we report RMSE excluding them. RMSE for μ from DL‐DECT mono‐E was below 1.9%. For the evaluation inserts at D = 150 mm and V = 140 kV, RED RMSE was 1.0%, while for EAN it was 2.9%. RSP RMSE was below 0.8% for all D and V, which did not strongly affect the results. Conclusions: In this investigation of RSP accuracy from DL‐DECT, we have shown that RMSE below 1% can be achieved. It was possible to adapt the YSL method for DL‐DECT and intermediate quantities RED and EAN had comparable accuracy to previous publications. … (more)
- Is Part Of:
- Medical physics. Volume 46:Issue 4(2019)
- Journal:
- Medical physics
- Issue:
- Volume 46:Issue 4(2019)
- Issue Display:
- Volume 46, Issue 4 (2019)
- Year:
- 2019
- Volume:
- 46
- Issue:
- 4
- Issue Sort Value:
- 2019-0046-0004-0000
- Page Start:
- 1821
- Page End:
- 1828
- Publication Date:
- 2019-02-19
- Subjects:
- dual‐energy CT -- dual‐layer CT -- monoenergetic imaging -- proton therapy -- relative stopping power -- synchrotron CT
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.13404 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18026.xml