The accuracy and precision of the KIM motion monitoring system used in the multi‐institutional TROG 15.01 Stereotactic Prostate Ablative Radiotherapy with KIM (SPARK) trial. Issue 11 (20th September 2019)
- Record Type:
- Journal Article
- Title:
- The accuracy and precision of the KIM motion monitoring system used in the multi‐institutional TROG 15.01 Stereotactic Prostate Ablative Radiotherapy with KIM (SPARK) trial. Issue 11 (20th September 2019)
- Main Title:
- The accuracy and precision of the KIM motion monitoring system used in the multi‐institutional TROG 15.01 Stereotactic Prostate Ablative Radiotherapy with KIM (SPARK) trial
- Authors:
- Hewson, Emily A.
Nguyen, Doan Trang
O'Brien, Ricky
Kim, Jung‐Ha
Montanaro, Tim
Moodie, Trevor
Greer, Peter B.
Hardcastle, Nicholas
Eade, Thomas
Kneebone, Andrew
Hruby, George
Hayden, Amy J.
Turner, Sandra
Siva, Shankar
Tai, Keen‐Hun
Hunter, Perry
Sams, Joshua
Poulsen, Per Rugaard
Booth, Jeremy T.
Martin, Jarad
Keall, Paul J. - Abstract:
- Abstract : Purpose: Kilovoltage intrafraction monitoring (KIM) allows for real‐time image guidance for tracking tumor motion in six‐degrees‐of‐freedom (6DoF) on a standard linear accelerator. This study assessed the geometric accuracy and precision of KIM used to guide patient treatments in the TROG 15.01 multi‐institutional Stereotactic Prostate Ablative Radiotherapy with KIM trial and investigated factors affecting accuracy and precision. Methods: Fractions from 44 patients with prostate cancer treated using KIM‐guided SBRT were analyzed across four institutions, on two different linear accelerator models and two different beam models (6 MV and 10 MV FFF). The geometric accuracy and precision of KIM was assessed from over 33 000 images (translation) and over 9000 images (rotation) by comparing the real‐time measured motion to retrospective kV/MV triangulation. Factors potentially affecting accuracy, including contrast‐to‐noise ratio (CNR) of kV images and incorrect marker segmentation, were also investigated. Results: The geometric accuracy and precision did not depend on treatment institution, beam model or motion magnitude, but was correlated with gantry angle. The centroid geometric accuracy and precision of the KIM system for SABR prostate treatments was 0.0 ± 0.5, 0.0 ± 0.4 and 0.1 ± 0.3 mm for translation, and −0.1 ± 0.6°, −0.1 ± 1.4° and −0.1 ± 1.0° for rotation in the AP, LR and SI directions respectively. Centroid geometric error exceeded 2 mm for 0.05% of thisAbstract : Purpose: Kilovoltage intrafraction monitoring (KIM) allows for real‐time image guidance for tracking tumor motion in six‐degrees‐of‐freedom (6DoF) on a standard linear accelerator. This study assessed the geometric accuracy and precision of KIM used to guide patient treatments in the TROG 15.01 multi‐institutional Stereotactic Prostate Ablative Radiotherapy with KIM trial and investigated factors affecting accuracy and precision. Methods: Fractions from 44 patients with prostate cancer treated using KIM‐guided SBRT were analyzed across four institutions, on two different linear accelerator models and two different beam models (6 MV and 10 MV FFF). The geometric accuracy and precision of KIM was assessed from over 33 000 images (translation) and over 9000 images (rotation) by comparing the real‐time measured motion to retrospective kV/MV triangulation. Factors potentially affecting accuracy, including contrast‐to‐noise ratio (CNR) of kV images and incorrect marker segmentation, were also investigated. Results: The geometric accuracy and precision did not depend on treatment institution, beam model or motion magnitude, but was correlated with gantry angle. The centroid geometric accuracy and precision of the KIM system for SABR prostate treatments was 0.0 ± 0.5, 0.0 ± 0.4 and 0.1 ± 0.3 mm for translation, and −0.1 ± 0.6°, −0.1 ± 1.4° and −0.1 ± 1.0° for rotation in the AP, LR and SI directions respectively. Centroid geometric error exceeded 2 mm for 0.05% of this dataset. No significant relationship was found between large geometric error and CNR or marker segmentation correlation. Conclusions: This study demonstrated the ability of KIM to locate the prostate with accuracy below other uncertainties in radiotherapy treatments, and the feasibility for KIM to be implemented across multiple institutions. … (more)
- Is Part Of:
- Medical physics. Volume 46:Issue 11(2019)
- Journal:
- Medical physics
- Issue:
- Volume 46:Issue 11(2019)
- Issue Display:
- Volume 46, Issue 11 (2019)
- Year:
- 2019
- Volume:
- 46
- Issue:
- 11
- Issue Sort Value:
- 2019-0046-0011-0000
- Page Start:
- 4725
- Page End:
- 4737
- Publication Date:
- 2019-09-20
- Subjects:
- geometric accuracy -- kilovoltage intrafraction monitoring -- prostate motion -- real‐time image guided radiotherapy -- SABR -- six‐degrees‐of‐freedom
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.13784 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18010.xml