Technical Note: Manufacturing of a realistic mouse phantom for dosimetry of radiobiology experiments. Issue 2 (21st January 2019)
- Record Type:
- Journal Article
- Title:
- Technical Note: Manufacturing of a realistic mouse phantom for dosimetry of radiobiology experiments. Issue 2 (21st January 2019)
- Main Title:
- Technical Note: Manufacturing of a realistic mouse phantom for dosimetry of radiobiology experiments
- Authors:
- Esplen, Nolan
Alyaqoub, Eisa
Bazalova‐Carter, Magdalena - Abstract:
- Abstract : Purpose: The goal of this work was to design a realistic mouse phantom as a useful tool for accurate dosimetry in radiobiology experiments. Methods: A subcutaneous tumor‐bearing mouse was scanned in a microCT scanner, its organs manually segmented and contoured. The resulting geometries were converted into a stereolithographic file format (STL) and sent to a multimaterial 3D printer. The phantom was split into two parts to allow for lung excavation and 3D‐printed with an acrylic‐like material and consisted of the main body (mass density ρ =1.18 g/cm 3 ) and bone ( ρ =1.20 g/cm 3 ). The excavated lungs were filled with polystyrene ( ρ =0.32 g/cm 3 ). Three cavities were excavated to allow the placement of a 1‐mm diameter plastic scintillator dosimeter (PSD) in the brain, the center of the body and a subcutaneous tumor. Additionally, a laser‐cut Gafchromic film can be placed in between the two phantom parts for 2D dosimetric evaluation. The expected differences in dose deposition between mouse tissues and the mouse phantom for a 220‐kVp beam delivered by the small animal radiation research platform (SARRP) were calculated by Monte Carlo (MC). Results: MicroCT scans of the phantom showed excellent material uniformity and confirmed the material densities given by the manufacturer. MC dose calculations revealed that the dose measured by tissue‐equivalent dosimeters inserted into the phantom in the brain, abdomen, and subcutaneous tumor would be underestimated by 3–5%,Abstract : Purpose: The goal of this work was to design a realistic mouse phantom as a useful tool for accurate dosimetry in radiobiology experiments. Methods: A subcutaneous tumor‐bearing mouse was scanned in a microCT scanner, its organs manually segmented and contoured. The resulting geometries were converted into a stereolithographic file format (STL) and sent to a multimaterial 3D printer. The phantom was split into two parts to allow for lung excavation and 3D‐printed with an acrylic‐like material and consisted of the main body (mass density ρ =1.18 g/cm 3 ) and bone ( ρ =1.20 g/cm 3 ). The excavated lungs were filled with polystyrene ( ρ =0.32 g/cm 3 ). Three cavities were excavated to allow the placement of a 1‐mm diameter plastic scintillator dosimeter (PSD) in the brain, the center of the body and a subcutaneous tumor. Additionally, a laser‐cut Gafchromic film can be placed in between the two phantom parts for 2D dosimetric evaluation. The expected differences in dose deposition between mouse tissues and the mouse phantom for a 220‐kVp beam delivered by the small animal radiation research platform (SARRP) were calculated by Monte Carlo (MC). Results: MicroCT scans of the phantom showed excellent material uniformity and confirmed the material densities given by the manufacturer. MC dose calculations revealed that the dose measured by tissue‐equivalent dosimeters inserted into the phantom in the brain, abdomen, and subcutaneous tumor would be underestimated by 3–5%, which is deemed to be an acceptable error assuming the proposed 5% accuracy of radiobiological experiments. Conclusions: The low‐cost mouse phantom can be easily manufactured and, after a careful dosimetric characterization, may serve as a useful tool for dose verification in a range of radiobiology experiments. … (more)
- Is Part Of:
- Medical physics. Volume 46:Issue 2(2019)
- Journal:
- Medical physics
- Issue:
- Volume 46:Issue 2(2019)
- Issue Display:
- Volume 46, Issue 2 (2019)
- Year:
- 2019
- Volume:
- 46
- Issue:
- 2
- Issue Sort Value:
- 2019-0046-0002-0000
- Page Start:
- 1030
- Page End:
- 1036
- Publication Date:
- 2019-01-21
- Subjects:
- 3D printing -- phantom -- small animal radiotherapy
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.13310 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18001.xml