AB0847 Accurate assessment of femoral echosound approach performance through dxa error analysis. (15th June 2017)
- Record Type:
- Journal Article
- Title:
- AB0847 Accurate assessment of femoral echosound approach performance through dxa error analysis. (15th June 2017)
- Main Title:
- AB0847 Accurate assessment of femoral echosound approach performance through dxa error analysis
- Authors:
- Muratore, M
Conversano, F
Pisani, P
Peccarisi, M
Greco, A
Marco, T De
Quarta, E
Quarta, L
Grimaldi, A
Casciaro, S - Abstract:
- Abstract : Background: Currently, the accepted "gold standard" method for bone mineral density (BMD) measurement and osteoporosis diagnosis related to the reference axial anatomical sites is dual-energy X-ray absorptiometry (DXA). However, actual DXA effectiveness is limited by several factors, including intrinsic accuracy uncertainties and specific errors in patient positioning, image segmentation, and post-acquisition data analysis, as documented by very recent literature [1]. This may affect the comparative evaluation of the effectiveness of novel diagnostic methods whose validation studies adopt DXA outcomes as standard reference to assess diagnostic performance. Objectives: To assess the impact of DXA errors on the performance of an innovative ultrasound parameter for osteoporosis diagnosis on the femoral site, known as Osteoporosis Score (OS). Methods: 202 patients aged in 46–75 years underwent two diagnostic investigations on the femoral neck: a conventional femoral DXA and an echographic scan performed by employing the innovative EchoSound technology [2]. Initially, the performance of the OS parameter was evaluated considering all the available DXA reports as reference in the data analysis, and calculating the corresponding accuracy in patient classification (osteoporotic, osteopenic, or healthy) and the correlation coefficient between the DXA-measured BMDs and the OS-derived BMD values. At a later stage, the DXA errors were taken into account by performing a strictAbstract : Background: Currently, the accepted "gold standard" method for bone mineral density (BMD) measurement and osteoporosis diagnosis related to the reference axial anatomical sites is dual-energy X-ray absorptiometry (DXA). However, actual DXA effectiveness is limited by several factors, including intrinsic accuracy uncertainties and specific errors in patient positioning, image segmentation, and post-acquisition data analysis, as documented by very recent literature [1]. This may affect the comparative evaluation of the effectiveness of novel diagnostic methods whose validation studies adopt DXA outcomes as standard reference to assess diagnostic performance. Objectives: To assess the impact of DXA errors on the performance of an innovative ultrasound parameter for osteoporosis diagnosis on the femoral site, known as Osteoporosis Score (OS). Methods: 202 patients aged in 46–75 years underwent two diagnostic investigations on the femoral neck: a conventional femoral DXA and an echographic scan performed by employing the innovative EchoSound technology [2]. Initially, the performance of the OS parameter was evaluated considering all the available DXA reports as reference in the data analysis, and calculating the corresponding accuracy in patient classification (osteoporotic, osteopenic, or healthy) and the correlation coefficient between the DXA-measured BMDs and the OS-derived BMD values. At a later stage, the DXA errors were taken into account by performing a strict quality control on DXA reports: all those cases affected by a typical inaccuracy [1] were excluded from the analysis and the actual diagnostic accuracy of the EchoSound technology was re-assessed by analysing only the reliable DXA reports. Intra- and inter-operator repeatability of OS-derived BMD values were also measured in a group of patients. Results: A diagnostic accuracy of 84.4% ( r =0.78, p <0.001) was obtained for the EchoSound approach when all the DXA reports were included in the analysis. In the second part of the study, 61 out of the initial 202 (30.4%) patients were excluded from the analysis because their DXA reports were affected by specific errors. An actual diagnostic accuracy of 94.2% was then obtained on the remaining 141 patients, together with a high correlation between DXA-measured BMDs and OS-derived BMD values ( r =0.88, p <0.001). Intra- and inter-operator repeatability of OS-derived BMD values, expressed in terms of the root mean square coefficient of variation (RMS-CV), resulted equal to 0.29% and 0.34% for intra- and inter-operator variability, respectively, therefore documenting a very good measurement repeatability. Conclusions: Undetected DXA errors had an impact on the accuracy evaluation of EchoSound femoral neck densitometry, causing an underestimation of OS performance in osteoporosis diagnosis. The quality control analysis on DXA reports can be useful to study the actual performance of different ultrasonic methods that considered routine DXA reports as the gold standard reference. References: Eur Radiol 2015;25:1504. UMB 2015;41:281. Acknowledgements: Work partially funded by FESR PO Apulia Region 2007–13 – Action 1.2.4 (grant n. 3Q5AX31: ECHOLIGHT Project). Disclosure of Interest: M. Muratore: None declared, F. Conversano Shareholder of: Echolight spa, a National Research Council spin-off that may or may not benefit from results of this study, P. Pisani: None declared, M. Peccarisi Employee of: Echolight Spa, A. Greco Employee of: Echolight Spa, T. De Marco Employee of: Echolight Spa, E. Quarta: None declared, L. Quarta: None declared, A. Grimaldi: None declared, S. Casciaro Shareholder of: Echolight spa, a National Research Council spin-off that may or may not benefit from results of this study … (more)
- Is Part Of:
- Annals of the rheumatic diseases. Volume 76(2017)Supplement 2
- Journal:
- Annals of the rheumatic diseases
- Issue:
- Volume 76(2017)Supplement 2
- Issue Display:
- Volume 76, Issue 2 (2017)
- Year:
- 2017
- Volume:
- 76
- Issue:
- 2
- Issue Sort Value:
- 2017-0076-0002-0000
- Page Start:
- 1353
- Page End:
- 1353
- Publication Date:
- 2017-06-15
- Subjects:
- Rheumatism -- Periodicals
616.723005 - Journal URLs:
- http://ard.bmjjournals.com/ ↗
http://www.pubmedcentral.nih.gov/tocrender.fcgi?journal=149&action=archive ↗
http://www.bmj.com/archive ↗
http://gateway.ovid.com/server3/ovidweb.cgi?T=JS&MODE=ovid&D=ovft&PAGE=titles&SEARCH=annals+of+the+rheumatic+diseases.tj&NEWS=N ↗ - DOI:
- 10.1136/annrheumdis-2017-eular.4843 ↗
- Languages:
- English
- ISSNs:
- 0003-4967
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18003.xml