Feasibility of sub-milliSievert CT of the cervical spine: Initial results in fresh human cadavers. Issue 120 (November 2019)
- Record Type:
- Journal Article
- Title:
- Feasibility of sub-milliSievert CT of the cervical spine: Initial results in fresh human cadavers. Issue 120 (November 2019)
- Main Title:
- Feasibility of sub-milliSievert CT of the cervical spine: Initial results in fresh human cadavers
- Authors:
- Weinrich, Julius Matthias
Regier, Marc
Well, Lennart
Bannas, Peter
Nykolyn, Oleh
Heinemann, Axel
Sehner, Susanne
Behzadi, Cyrus
Püschel, Klaus
Adam, Gerhard
Laqmani, Azien - Abstract:
- Highlights: Sub-milli-Sievert cervical spine CT is feasible with 30 mAs at 140 kV. Decreased image quality of the lower cervical spine limits further dose reduction. RDCT cervical spine CT with IR could be suitable for isolated cervical trauma. Abstract: Purpose: To investigate the feasibility of sub-milliSievert CT of the cervical spine in fresh human cadavers using a standard-dose (SD) and four different reduced-dose (RD) protocols reconstructed with filtered back projection (FBP) and iterative reconstruction (IR). Methods: The cervical spine of 29 cadavers was examined using different RDCT protocols with decreasing reference tube currents (RDCT-1:70 mAs; RDCT-2:50 mAs; RDCT-3:30 mAs; RDCT-4:10 mAs) at 140 kV. A clinical SDCT (160 mAs, 120 kV) served as reference. Raw data were reconstructed using FBP and two increasing levels of IR (IRL4&6). Images of the upper (C1–4) and lower (C5–7) cervical spine were evaluated for image quality, diagnostic acceptability and visibility of anatomical structures according to a 5-point-scale. Results: Image quality of the upper cervical spine was diagnostically acceptable for all protocols using FBP and IR except for RDCT-4 with FBP. Image quality of the lower cervical spine was rated as non-diagnostic in RDCT-3 with FBP and RDCT-4 with FBP and IR. RDCT-3 with IR was the most reduced dose CT protocol allowing diagnostically acceptable image quality for both upper and lower cervical spine in all cadavers. RDCT protocols achievedHighlights: Sub-milli-Sievert cervical spine CT is feasible with 30 mAs at 140 kV. Decreased image quality of the lower cervical spine limits further dose reduction. RDCT cervical spine CT with IR could be suitable for isolated cervical trauma. Abstract: Purpose: To investigate the feasibility of sub-milliSievert CT of the cervical spine in fresh human cadavers using a standard-dose (SD) and four different reduced-dose (RD) protocols reconstructed with filtered back projection (FBP) and iterative reconstruction (IR). Methods: The cervical spine of 29 cadavers was examined using different RDCT protocols with decreasing reference tube currents (RDCT-1:70 mAs; RDCT-2:50 mAs; RDCT-3:30 mAs; RDCT-4:10 mAs) at 140 kV. A clinical SDCT (160 mAs, 120 kV) served as reference. Raw data were reconstructed using FBP and two increasing levels of IR (IRL4&6). Images of the upper (C1–4) and lower (C5–7) cervical spine were evaluated for image quality, diagnostic acceptability and visibility of anatomical structures according to a 5-point-scale. Results: Image quality of the upper cervical spine was diagnostically acceptable for all protocols using FBP and IR except for RDCT-4 with FBP. Image quality of the lower cervical spine was rated as non-diagnostic in RDCT-3 with FBP and RDCT-4 with FBP and IR. RDCT-3 with IR was the most reduced dose CT protocol allowing diagnostically acceptable image quality for both upper and lower cervical spine in all cadavers. RDCT protocols achieved significantly reduced effective radiation doses (SDCT: 1.5 ± 0.7 mSv; RDCT-1:1 ± 0.6 mSv; RDCT-2:0.7 ± 0.4 mSv; RDCT-3:0.4 ± 0.2 mSv; RDCT-4:0.2 ± 0.1 mSv; p < 0.001). Conclusion: Diagnostically acceptable sub-milliSievert CT of the cervical spine is feasible with a low reference tube current at 140 kV using iterative reconstruction and could be suitable for isolated cervical trauma in cooperative patients. … (more)
- Is Part Of:
- European journal of radiology. Issue 120(2019)
- Journal:
- European journal of radiology
- Issue:
- Issue 120(2019)
- Issue Display:
- Volume 120, Issue 120 (2019)
- Year:
- 2019
- Volume:
- 120
- Issue:
- 120
- Issue Sort Value:
- 2019-0120-0120-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-11
- Subjects:
- Computed tomography -- CT -- Radiation dose reduction -- Cervical spine -- Iterative reconstruction -- Cadaver
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2019.108697 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18025.xml