Patient-assisted compression helps for image quality reduction dose and improves patient experience in mammography. (November 2018)
- Record Type:
- Journal Article
- Title:
- Patient-assisted compression helps for image quality reduction dose and improves patient experience in mammography. (November 2018)
- Main Title:
- Patient-assisted compression helps for image quality reduction dose and improves patient experience in mammography
- Authors:
- Balleyguier, Corinne
Cousin, Morgane
Dunant, Ariane
Attard, Marie
Delaloge, Suzette
Arfi-Rouche, Julia - Abstract:
- Abstract: We evaluated the impact of patient-assisted compression (PAC) on image quality, dose, workflow and patient experience of mammography. Patients aged 40–90 years coming for bilateral mammography were included prospectively in the study. After positioning each breast, the technologist performed the compression and exposure of the first breast, initiated the compression of the other until 3 daN and then let the patient complete the compression using a remote control device. Image quality, compression force, breast thickness, average glandular dose and pain value for each breast were assessed for PAC and technologist compression (TC). The compression level was significantly higher with PAC than TC for both craniocaudal (CC; median difference 2.0 daN, p < 0.0001) and mediolateral oblique (MLO) views (median difference 1.5 daN, p < 0.0001). Breast thickness was reduced with PAC (CC, median difference −1.90 cm, p = 0.02), as well as glandular dose (CC, median difference −0.03, p = 0.02). The image quality was rated equivalent for both modes in 85% (85/100) of cases, superior for PAC in 10% (10/100) of cases and inferior in 5% (5/100) of cases. There was no significant difference in discomfort or pain felt between PAC and TC modes. Seventy-four percent of patients reported that the self-compressing device would facilitate their reattendance. PAC may be a suitable technique for mammography examinations, providing an equivalent image quality to TC. Moreover, as the breastAbstract: We evaluated the impact of patient-assisted compression (PAC) on image quality, dose, workflow and patient experience of mammography. Patients aged 40–90 years coming for bilateral mammography were included prospectively in the study. After positioning each breast, the technologist performed the compression and exposure of the first breast, initiated the compression of the other until 3 daN and then let the patient complete the compression using a remote control device. Image quality, compression force, breast thickness, average glandular dose and pain value for each breast were assessed for PAC and technologist compression (TC). The compression level was significantly higher with PAC than TC for both craniocaudal (CC; median difference 2.0 daN, p < 0.0001) and mediolateral oblique (MLO) views (median difference 1.5 daN, p < 0.0001). Breast thickness was reduced with PAC (CC, median difference −1.90 cm, p = 0.02), as well as glandular dose (CC, median difference −0.03, p = 0.02). The image quality was rated equivalent for both modes in 85% (85/100) of cases, superior for PAC in 10% (10/100) of cases and inferior in 5% (5/100) of cases. There was no significant difference in discomfort or pain felt between PAC and TC modes. Seventy-four percent of patients reported that the self-compressing device would facilitate their reattendance. PAC may be a suitable technique for mammography examinations, providing an equivalent image quality to TC. Moreover, as the breast compression level is increased, PAC may help reduce breast thickness, hence glandular dose. The fact that patients have control over the procedure may change their perception of mammography and improve uptake and compliance. Highlights: Patient-assisted compression doesn't impair mammogram quality. Patient-assisted compression increases breast compression and lower radiation dose. Anxiety linked to mammography may be reduced by this new technic. … (more)
- Is Part Of:
- European journal of cancer. Volume 103(2018)
- Journal:
- European journal of cancer
- Issue:
- Volume 103(2018)
- Issue Display:
- Volume 103, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 103
- Issue:
- 2018
- Issue Sort Value:
- 2018-0103-2018-0000
- Page Start:
- 137
- Page End:
- 142
- Publication Date:
- 2018-11
- Subjects:
- Mammography -- Self-compression -- Dose -- Pain -- Image quality -- Breast cancer
Cancer -- Periodicals
Neoplasms -- Periodicals
Cancer -- Périodiques
Cancer
Tumors
Electronic journals
Periodicals
Electronic journals
616.994 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09598049 ↗
http://rzblx1.uni-regensburg.de/ezeit/warpto.phtml?colors=7&jour_id=2879 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/09598049 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/09598049 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejca.2018.08.009 ↗
- Languages:
- English
- ISSNs:
- 0959-8049
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.725100
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 17998.xml