AB1059 2D Histogram Ultrasound and 3D Ultrasound Correlation in Rheumatic Diseases. (9th June 2015)
- Record Type:
- Journal Article
- Title:
- AB1059 2D Histogram Ultrasound and 3D Ultrasound Correlation in Rheumatic Diseases. (9th June 2015)
- Main Title:
- AB1059 2D Histogram Ultrasound and 3D Ultrasound Correlation in Rheumatic Diseases
- Authors:
- Mendonça, J.A.
Provenza, J.R.
Guissa, V.R.
Vierhout, C.V.
Pedri, L.E.
Frazon, P.G.U.
Lyrio, A.M.
Peron Filho, F.
Bonfiglioli, R.
Schincariol, N.B. - Abstract:
- Abstract : Background: High frequency linear probe ultrasound (US), besides allowing a better resolution in the gray scale (GS), is able to characterize colored images standards through a RGB image histogram 1 . These images develop through the information of additive primary colors, such as Red (R), Green (G) and Blue (B). On the other hand, the 3D US 2 can better define the anatomical cuts, with more details, yielding more precise measures, together with the 2D US. These two methods are able to define echotextural damages, thus enhancing the detection of such changes in rheumatic diseases. Objectives: To detect echotextural damages through 2D and 3D US correlating these area and volumes measures. Methods: A total of 16 patients have been assessed (37.5% males and 62.5% females); 75% were affected by synovitis in their wrists, knees, metacarpophalangeal joint, distal interphalangeal joint, hips, ankle, metatarsophalangeal joint; 6.3% exhibited tenossynovitis, 6.3% tophus, 6.3% synovial cyst, 6.3% femoral-condyle cartilage, including 2 rheumatoid arthritis, 5 juvenile idiopathic arthritis, 4 gouts, 1 psoriatic arthritis, 2 osteoarthritis, 1 non-differentiated spondiloarthritis and 1 reactive arthropathy. A MyLab 50 -Esaote equipment was used with frequency transducer that ranged between 6.0 and 18.0 MHz for 2D, and with frequency that ranged from 10.0 to 12.0 MHz for 3D. A total of 630 images was obtained, 470 were in 2 D and 160 images in 3D. For each GS measurement thereAbstract : Background: High frequency linear probe ultrasound (US), besides allowing a better resolution in the gray scale (GS), is able to characterize colored images standards through a RGB image histogram 1 . These images develop through the information of additive primary colors, such as Red (R), Green (G) and Blue (B). On the other hand, the 3D US 2 can better define the anatomical cuts, with more details, yielding more precise measures, together with the 2D US. These two methods are able to define echotextural damages, thus enhancing the detection of such changes in rheumatic diseases. Objectives: To detect echotextural damages through 2D and 3D US correlating these area and volumes measures. Methods: A total of 16 patients have been assessed (37.5% males and 62.5% females); 75% were affected by synovitis in their wrists, knees, metacarpophalangeal joint, distal interphalangeal joint, hips, ankle, metatarsophalangeal joint; 6.3% exhibited tenossynovitis, 6.3% tophus, 6.3% synovial cyst, 6.3% femoral-condyle cartilage, including 2 rheumatoid arthritis, 5 juvenile idiopathic arthritis, 4 gouts, 1 psoriatic arthritis, 2 osteoarthritis, 1 non-differentiated spondiloarthritis and 1 reactive arthropathy. A MyLab 50 -Esaote equipment was used with frequency transducer that ranged between 6.0 and 18.0 MHz for 2D, and with frequency that ranged from 10.0 to 12.0 MHz for 3D. A total of 630 images was obtained, 470 were in 2 D and 160 images in 3D. For each GS measurement there were 10 measures of 2D standard colored images as well as 3D correlation images of the original GS image, taken at different times in order not to remind prior measurements. Results: Average age 39.93±25.98 years of age; average measurement of 2D image area: (GS) 159.23±174.98 cm 2, (Indigo) 126.86±156.98 cm 2, (RGB) 117.78±142.71 cm 2 and average measurement of 3D images 0.588±0.812 cm 3 . Correlations 2D: (GS) with (Indigo): r =0.948; p <0. 001; (GS) with (RGB) r =0.979; p <0. 001; (Indigo) with (RGB) r =0.987; p <0.001. Correlations 3D and 2D: (GS) r =0.757; p =0.001; (Indigo) r =0.758; p =0.002 and (RGB) r =0.764; p =0.001. Conclusions: The 2D colored image standards, together with 3D images, may improve the precision of the echotextural damage boundaries in rheumatologic diseases. References: Marques Filho, O; Vieira Neto, H. Processamento Digital de Imagens, Rio de Janeiro: Brasport, 1999. ISBN8574520098. Mendonça JA. O US Tridimensional (3D US). Ultrassonografia em Reumatologia: Uma Extensão do Exame Físico. Rio de Janeiro: Revinter, 2014. p. 70-76. Disclosure of Interest: None declared … (more)
- Is Part Of:
- Annals of the rheumatic diseases. Volume 74(2015)Supplement 2
- Journal:
- Annals of the rheumatic diseases
- Issue:
- Volume 74(2015)Supplement 2
- Issue Display:
- Volume 74, Issue 2 (2015)
- Year:
- 2015
- Volume:
- 74
- Issue:
- 2
- Issue Sort Value:
- 2015-0074-0002-0000
- Page Start:
- 1253
- Page End:
- 1254
- Publication Date:
- 2015-06-09
- Subjects:
- Rheumatism -- Periodicals
616.723005 - Journal URLs:
- http://ard.bmjjournals.com/ ↗
http://www.pubmedcentral.nih.gov/tocrender.fcgi?journal=149&action=archive ↗
http://www.bmj.com/archive ↗
http://gateway.ovid.com/server3/ovidweb.cgi?T=JS&MODE=ovid&D=ovft&PAGE=titles&SEARCH=annals+of+the+rheumatic+diseases.tj&NEWS=N ↗ - DOI:
- 10.1136/annrheumdis-2015-eular.1985 ↗
- Languages:
- English
- ISSNs:
- 0003-4967
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17997.xml