Monte Carlo simulation of a new TEPC for microdosimetry at nanometric level: Response against a carbon ion beam. (June 2018)
- Record Type:
- Journal Article
- Title:
- Monte Carlo simulation of a new TEPC for microdosimetry at nanometric level: Response against a carbon ion beam. (June 2018)
- Main Title:
- Monte Carlo simulation of a new TEPC for microdosimetry at nanometric level: Response against a carbon ion beam
- Authors:
- Mazzucconi, D.
Bortot, D.
Pola, A.
Agosteo, S.
Pasquato, S.
Fazzi, A.
Colautti, P.
Conte, V. - Abstract:
- Abstract: The lower operation limit of common tissue equivalent proportional counters (TEPCs) is about 0.3 μm in simulated site. On the other hand, the pattern of the particle interactions at the nanometric level, which has a correlation with the radiation induced damage on the DNA, is measurable by only three instruments worldwide. In order to fill this gap, a novel TEPC capable of simulating site sizes down to 25 nm was designed and constructed. Its response was characterized with gamma, neutron and carbon beams and the capability in measuring microdosimetric spectra at 25 nm was demonstrated. The present paper aims at describing a further characterization of this TEPC by simulating with the Monte Carlo FLUKA code the microdosimetric spectra measured with a carbon beam. Since the sensitive volume of the TEPC has an unconventional shape, a study on the chord length distribution for the adopted irradiation set-up was performed and compared with the analytical one. The results show a good agreement between the experimental data and the FLUKA simulations, showing that this code is capable of reproducing microdosimetric spectra of a carbon beam down to 25 nm in simulated site. Highlights: Avalanche-confinement TEPC able to simulate site sizes down to nanometric region. TEPC characterization with the Monte Carlo FLUKA code down to 25 nm. Chord length distribution of a carbon ion beam in the TEPC.
- Is Part Of:
- Radiation measurements. Volume 113(2018:Jun.)
- Journal:
- Radiation measurements
- Issue:
- Volume 113(2018:Jun.)
- Issue Display:
- Volume 113 (2018)
- Year:
- 2018
- Volume:
- 113
- Issue Sort Value:
- 2018-0113-0000-0000
- Page Start:
- 7
- Page End:
- 13
- Publication Date:
- 2018-06
- Subjects:
- Microdosimetry -- Nanodosimetry -- Tissue equivalent proportional counter (TEPC) -- FLUKA -- Monte Carlo simulation
Nuclear emulsions -- Periodicals
Particle tracks (Nuclear physics) -- Periodicals
Thermoluminescence -- Periodicals
Cosmic rays -- Periodicals
Radiation -- Measurement -- Periodicals
Radiometry -- Periodicals
Radiation Monitoring -- Periodicals
Émulsions nucléaires -- Périodiques
Particules (Physique nucléaire) -- Traces -- Périodiques
Thermoluminescence -- Périodiques
Rayonnement cosmique -- Périodiques
Radiométrie -- Périodiques
539.77 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13504487 ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiation-measurements/ ↗ - DOI:
- 10.1016/j.radmeas.2018.03.006 ↗
- Languages:
- English
- ISSNs:
- 1350-4487
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7227.973000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18013.xml