XEN Implant Fracture During Needling Procedure. Issue 12 (December 2019)
- Record Type:
- Journal Article
- Title:
- XEN Implant Fracture During Needling Procedure. Issue 12 (December 2019)
- Main Title:
- XEN Implant Fracture During Needling Procedure
- Authors:
- Olivari, Sara
Cutolo, Carlo A.
Negri, Letizia
Cappelli, Francesca
Testa, Valeria
Iester, Michele
Traverso, Carlo E. - Abstract:
- Abstract : Purpose: The XEN implant is a small hydrophilic stent designed to be implanted permanently for the treatment of glaucoma. As with other bleb-forming surgical procedures, needling is part of postoperative care. We describe 3 cases of XEN fracture of the subconjunctival portion that occurred during the needling procedure. Methods: The purpose of this study was to describe the clinical and anatomic outcomes in 3 cases of XEN fracture caused by the needling procedure. Results: In our case series of XEN procedures (n=170), bleb needling has been performed in 98 cases (57.6%). In 3 cases (3.1%), we observed unintentional damage to the implant after the procedure. The mean distal segment length of the fractured XEN measured 0.83 (range: 0.7 to 1) mm. Despite the adverse event, the mean IOP changed from 25.0 (range: 21 to 30) mm Hg before needling to 12.0 (range: 10 to 14) after needling, with a mean follow-up of 15.3 (range: 11 to 18) months. No vision-threatening complications were recorded during the entire follow-up. Conclusions: XEN fracture related to the needling procedure should be considered as a possible adverse event of bleb management. Because XEN is composed of a soft and flexible gelatin material, it could be easily damaged by the needle. The fracture does not seem to impair the efficacy of the draining device. As a matter of fact, according to Poiseuille's laws, shortening of the implant's length decreases the resistance while increasing the flow rate.Abstract : Purpose: The XEN implant is a small hydrophilic stent designed to be implanted permanently for the treatment of glaucoma. As with other bleb-forming surgical procedures, needling is part of postoperative care. We describe 3 cases of XEN fracture of the subconjunctival portion that occurred during the needling procedure. Methods: The purpose of this study was to describe the clinical and anatomic outcomes in 3 cases of XEN fracture caused by the needling procedure. Results: In our case series of XEN procedures (n=170), bleb needling has been performed in 98 cases (57.6%). In 3 cases (3.1%), we observed unintentional damage to the implant after the procedure. The mean distal segment length of the fractured XEN measured 0.83 (range: 0.7 to 1) mm. Despite the adverse event, the mean IOP changed from 25.0 (range: 21 to 30) mm Hg before needling to 12.0 (range: 10 to 14) after needling, with a mean follow-up of 15.3 (range: 11 to 18) months. No vision-threatening complications were recorded during the entire follow-up. Conclusions: XEN fracture related to the needling procedure should be considered as a possible adverse event of bleb management. Because XEN is composed of a soft and flexible gelatin material, it could be easily damaged by the needle. The fracture does not seem to impair the efficacy of the draining device. As a matter of fact, according to Poiseuille's laws, shortening of the implant's length decreases the resistance while increasing the flow rate. Despite our positive results, it is recommended to preserve the integrity of the implant. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Journal of glaucoma. Volume 28:Issue 12(2019)
- Journal:
- Journal of glaucoma
- Issue:
- Volume 28:Issue 12(2019)
- Issue Display:
- Volume 28, Issue 12 (2019)
- Year:
- 2019
- Volume:
- 28
- Issue:
- 12
- Issue Sort Value:
- 2019-0028-0012-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-12
- Subjects:
- glaucoma -- surgery -- XEN implant -- needling
Glaucoma -- Periodicals
617.741005 - Journal URLs:
- http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00061198-000000000-00000 ↗
http://www.glaucomajournal.com ↗
http://journals.lww.com/glaucomajournal/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/IJG.0000000000001360 ↗
- Languages:
- English
- ISSNs:
- 1057-0829
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4996.230000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18026.xml