Exergoeconomic-optimized design of a solar absorption-subcooled compression hybrid cooling system for use in low-rise buildings. (1st June 2018)
- Record Type:
- Journal Article
- Title:
- Exergoeconomic-optimized design of a solar absorption-subcooled compression hybrid cooling system for use in low-rise buildings. (1st June 2018)
- Main Title:
- Exergoeconomic-optimized design of a solar absorption-subcooled compression hybrid cooling system for use in low-rise buildings
- Authors:
- Jing, Yue
Li, Zeyu
Liu, Liming
Lu, Shengzi
Lv, Shiliang - Abstract:
- Highlights: Product cost flow rate and relative cost difference are taken as objective function. Collector scale should be designed by optimal absorption chiller size. Optimal size of absorption subsystem relies on solar irradiance and cooling load. Optimization difference base on two objectives is sensitive to solar irradiance. Optimization difference base on two objectives weakly depends on cooling demand. Abstract: An optimized design for a solar absorption-subcooled compression hybrid cooling system used in low-rise buildings is complicated because of the overall considerations involving increases in investment costs and energy savings, which are associated with an increase in the size of the absorption subsystem. To this end, this paper's main contribution lies in its exergoeconomic-optimized design of a solar absorption-subcooled compression hybrid cooling system employed in low-rise buildings for different design cases. In this paper, not only the minimum product-cost flow rate but also the lowest relative cost difference is taken as the objective function owing to the notable changes in fuel cost flow rates. The results of the exergoeconomic optimization shows that the actual cooling capacity of the absorption subsystem should not be designed based only on the maximum collector area. Instead, the actual installed collector area should be determined by the optimal cooling capacity of the absorption subsystem. It was also found that the optimal cooling capacity of theHighlights: Product cost flow rate and relative cost difference are taken as objective function. Collector scale should be designed by optimal absorption chiller size. Optimal size of absorption subsystem relies on solar irradiance and cooling load. Optimization difference base on two objectives is sensitive to solar irradiance. Optimization difference base on two objectives weakly depends on cooling demand. Abstract: An optimized design for a solar absorption-subcooled compression hybrid cooling system used in low-rise buildings is complicated because of the overall considerations involving increases in investment costs and energy savings, which are associated with an increase in the size of the absorption subsystem. To this end, this paper's main contribution lies in its exergoeconomic-optimized design of a solar absorption-subcooled compression hybrid cooling system employed in low-rise buildings for different design cases. In this paper, not only the minimum product-cost flow rate but also the lowest relative cost difference is taken as the objective function owing to the notable changes in fuel cost flow rates. The results of the exergoeconomic optimization shows that the actual cooling capacity of the absorption subsystem should not be designed based only on the maximum collector area. Instead, the actual installed collector area should be determined by the optimal cooling capacity of the absorption subsystem. It was also found that the optimal cooling capacity of the absorption subsystem strongly depends on solar irradiance and cooling demands. In addition, optimal sizes for the absorption subsystem should be designed according to the different minimum product cost flow rates or the lowest relative cost difference, and this difference is sensitive to the local mean solar irradiance but weakly relies on the cooling demand. The paper is helpful in its cost-effective design for a solar absorption-subcooled compression hybrid cooling system used in low-rise buildings. … (more)
- Is Part Of:
- Energy conversion and management. Volume 165(2018)
- Journal:
- Energy conversion and management
- Issue:
- Volume 165(2018)
- Issue Display:
- Volume 165, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 165
- Issue:
- 2018
- Issue Sort Value:
- 2018-0165-2018-0000
- Page Start:
- 465
- Page End:
- 476
- Publication Date:
- 2018-06-01
- Subjects:
- Solar cooling -- Absorption chiller -- Hybrid system -- Optimal design -- Exergoeconomics
Direct energy conversion -- Periodicals
Energy storage -- Periodicals
Energy transfer -- Periodicals
Énergie -- Conversion directe -- Périodiques
Direct energy conversion
Periodicals
621.3105 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01968904 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.enconman.2018.03.083 ↗
- Languages:
- English
- ISSNs:
- 0196-8904
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3747.547000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 18028.xml