Early versus newer generation devices for transcatheter aortic valve implantation in routine clinical practice: a propensity score matched analysis. Issue 1 (20th January 2018)
- Record Type:
- Journal Article
- Title:
- Early versus newer generation devices for transcatheter aortic valve implantation in routine clinical practice: a propensity score matched analysis. Issue 1 (20th January 2018)
- Main Title:
- Early versus newer generation devices for transcatheter aortic valve implantation in routine clinical practice: a propensity score matched analysis
- Authors:
- Pilgrim, Thomas
Lee, Joe K T
O'Sullivan, Crochan J
Stortecky, Stefan
Ariotti, Sara
Franzone, Anna
Lanz, Jonas
Heg, Dik
Asami, Masahiko
Praz, Fabien
Siontis, George C M
Vollenbroich, René
Räber, Lorenz
Valgimigli, Marco
Roost, Eva
Windecker, Stephan - Abstract:
- Abstract : Aim: Contemporary data comparing early versus newer generation transcatheter heart valve (THV) devices in routine clinical practice are lacking. We sought to compare the safety and efficacy of early versus newer generation THVs in unselected patients undergoing transcatheter aortic valve implantation (TAVI). Methods and results: We performed a propensity score matched analysis of patients undergoing transfemoral TAVI at a single centre with early versus newer generation devices between 2007 and 2016. Patients were matched for balloon-expandable versus self-expandable valves and Society of Thoracic Surgeons score. The primary end point was the Valve Academic Research Consortium (VARC)-2 early safety composite end point at 30 days. Among the 391 matched pairs, no differences between early (21.2%) and newer generation (20.8%) THVs regarding the early safety composite end point (HR 0.98, 95% CI 0.72 to 1.33, P=0.88) were observed. The rates of valve embolisation (0.8% vs 4.2%, P=0.005), bleeding events (24.8% vs 32.0%, P=0.028) and moderate-to-severe paravalvular regurgitation (PVR) (3.1% vs 12.1%, P<0.001) were lower among patients receiving newer generation devices. Conversely, patients treated with early generation THVs less frequently experienced annulus rupture (0% vs 2.0%, P=0.008). Conclusion: Newer compared with early generation THV devices were associated with a lower rate of valve embolisation, PVR and bleeding events.
- Is Part Of:
- Open heart. Volume 5:Issue 1(2018)
- Journal:
- Open heart
- Issue:
- Volume 5:Issue 1(2018)
- Issue Display:
- Volume 5, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 5
- Issue:
- 1
- Issue Sort Value:
- 2018-0005-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-01-20
- Subjects:
- valvular disease -- aortic valve disease
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
Heart -- Diseases -- Patients -- Periodicals
616.12005 - Journal URLs:
- http://www.bmj.com/archive ↗
http://openheart.bmj.com/ ↗ - DOI:
- 10.1136/openhrt-2017-000695 ↗
- Languages:
- English
- ISSNs:
- 2398-595X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17992.xml