Knots Tied With High–Tensile Strength Tape Biomechanically Outperform Knots Tied With Round Suture. Issue 10 (5th October 2021)
- Record Type:
- Journal Article
- Title:
- Knots Tied With High–Tensile Strength Tape Biomechanically Outperform Knots Tied With Round Suture. Issue 10 (5th October 2021)
- Main Title:
- Knots Tied With High–Tensile Strength Tape Biomechanically Outperform Knots Tied With Round Suture
- Authors:
- Hong, Chih-Kai
Chuang, Hao-Chun
Hsu, Kai-Lan
Kuan, Fa-Chuan
Chen, Yueh
Yeh, Ming-Long
Su, Wei-Ren - Abstract:
- Background: Tape-type suture material is well-accepted in arthroscopy surgery. Purpose: To compare the knot security of a high–tensile strength round suture and high–tensile strength tape with commonly used arthroscopic knots. Study Design: Controlled laboratory study. Methods: We compared the performance of No. 2 braided nonabsorbable high-strength suture with that of 1.3-mm braided nonabsorbable high-strength tape. Five commonly used arthroscopic knots were investigated: the Roeder knot; the Western knot; the Samsung Medical Center (SMC) knot; the Tennessee knot; and a static surgeon's knot. Seven knots were tied for each combination of knots and suture types. Knots were tied on a 30-mm circumferential metal post, and the suture loops were transferred to a materials testing machine. After preloading to 5 N, all specimens were loaded to failure. The clinical failure load, defined as the maximal force to failure at 3 mm of crosshead displacement, yield load, and stiffness, were recorded. A 2-way analysis of variance was used to determine differences between the groups. Results: Both suture type and knot type significantly affected the clinical failure load, yield load, and stiffness ( P = .002). The high-strength tape resulted in a significantly greater clinical failure load than the high-strength suture in the case of the Roeder knot, Western knot, and SMC knot ( P = .027, .005, and .016, respectively). When the high-strength round suture was used, the Roeder knot, WesternBackground: Tape-type suture material is well-accepted in arthroscopy surgery. Purpose: To compare the knot security of a high–tensile strength round suture and high–tensile strength tape with commonly used arthroscopic knots. Study Design: Controlled laboratory study. Methods: We compared the performance of No. 2 braided nonabsorbable high-strength suture with that of 1.3-mm braided nonabsorbable high-strength tape. Five commonly used arthroscopic knots were investigated: the Roeder knot; the Western knot; the Samsung Medical Center (SMC) knot; the Tennessee knot; and a static surgeon's knot. Seven knots were tied for each combination of knots and suture types. Knots were tied on a 30-mm circumferential metal post, and the suture loops were transferred to a materials testing machine. After preloading to 5 N, all specimens were loaded to failure. The clinical failure load, defined as the maximal force to failure at 3 mm of crosshead displacement, yield load, and stiffness, were recorded. A 2-way analysis of variance was used to determine differences between the groups. Results: Both suture type and knot type significantly affected the clinical failure load, yield load, and stiffness ( P = .002). The high-strength tape resulted in a significantly greater clinical failure load than the high-strength suture in the case of the Roeder knot, Western knot, and SMC knot ( P = .027, .005, and .016, respectively). When the high-strength round suture was used, the Roeder knot, Western knot, and SMC knot resulted in significantly smaller clinical failure loads compared with the Tennessee knot ( P = .011, .003, and .035, respectively) and the static surgeon's knot ( P < .001 for all). When the high-strength tape was used, the Roeder knot, Western knot, and SMC knot resulted in significantly smaller clinical failure loads compared with the static surgeon's knot ( P = .001, .001, and .003, respectively). Conclusion: The results of this study indicated that arthroscopic knots tied using 1.3-mm high-strength tape biomechanically outperformed knots tied using a No. 2 high-strength suture. While the static surgeon's knot exhibited the best biomechanical properties, the Tennessee knot resulted in generally better biomechanical properties among the arthroscopic sliding knots. Clinical Relevance: Elongation and loosening of tied knots possibly affects the clinical results of repaired constructs. … (more)
- Is Part Of:
- Orthopaedic journal of sports medicine. Volume 9:Issue 10(2021)
- Journal:
- Orthopaedic journal of sports medicine
- Issue:
- Volume 9:Issue 10(2021)
- Issue Display:
- Volume 9, Issue 10 (2021)
- Year:
- 2021
- Volume:
- 9
- Issue:
- 10
- Issue Sort Value:
- 2021-0009-0010-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-10-05
- Subjects:
- arthroscopy -- knot -- high-strength suture -- high-strength tape -- biomechanical
Sports medicine -- Periodicals
Orthopedics -- Periodicals
Arthroscopy -- Periodicals
Arthroplasty -- Periodicals
Knee -- Surgery -- Periodicals
616.7 - Journal URLs:
- http://www.sagepublications.com/ ↗
- DOI:
- 10.1177/23259671211039554 ↗
- Languages:
- English
- ISSNs:
- 2325-9671
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17990.xml