B-Lines Scores Derived From Lung Ultrasound Provide Accurate Prediction of Extravascular Lung Water Index: An Observational Study in Critically Ill Patients. (January 2022)
- Record Type:
- Journal Article
- Title:
- B-Lines Scores Derived From Lung Ultrasound Provide Accurate Prediction of Extravascular Lung Water Index: An Observational Study in Critically Ill Patients. (January 2022)
- Main Title:
- B-Lines Scores Derived From Lung Ultrasound Provide Accurate Prediction of Extravascular Lung Water Index: An Observational Study in Critically Ill Patients
- Authors:
- Mayr, Ulrich
Lukas, Marina
Habenicht, Livia
Wiessner, Johannes
Heilmaier, Markus
Ulrich, Jörg
Rasch, Sebastian
Schmid, Roland M.
Lahmer, Tobias
Huber, Wolfgang
Herner, Alexander - Abstract:
- Introduction: Visualization of B-lines via lung ultrasound provides a non-invasive estimation of pulmonary hydration. Extravascular lung water index (EVLWI) and pulmonary vascular permeability index (PVPI) assessed by transpulmonary thermodilution (TPTD) represent the most validated parameters of lung water and alveolocapillary permeability, but measurement is invasive and expensive. This study aimed to compare the correlations of B-lines scores from extensive 28-sector and simplified 4-sector chest scan with EVLWI and PVPI derived from TPTD in the setting of intensive care unit (primary endpoint). Methods: We performed scoring of 28-sector and 4-sector B-Lines in 50 critically ill patients. TPTD was carried out with the PiCCO-2-device (Pulsion Medical Systems SE, Maquet Getinge Group). Median time exposure for ultrasound procedure was 12 minutes for 28-sector and 4 minutes for 4-sector scan. Results: Primarily, we found close correlations of 28-sector as well as 4-sector B-Lines scores with EVLWI (R 2 = 0.895 vs. R 2 = 0.880) and PVPI (R 2 = 0.760 vs. R 2 = 0.742). Both B-lines scores showed high accuracy to identify patients with specific levels of EVLWI and PVPI. The extensive 28-sector B-lines score revealed a moderate advantage compared to simplified 4-sector scan in detecting a normal EVLWI ≤ 7 (28-sector scan: sensitivity = 81.8%, specificity = 94.9%, AUC = 0.939 versus 4-sector scan: sensitivity = 81.8%, specificity = 82.1%, AUC = 0.902). Both protocols wereIntroduction: Visualization of B-lines via lung ultrasound provides a non-invasive estimation of pulmonary hydration. Extravascular lung water index (EVLWI) and pulmonary vascular permeability index (PVPI) assessed by transpulmonary thermodilution (TPTD) represent the most validated parameters of lung water and alveolocapillary permeability, but measurement is invasive and expensive. This study aimed to compare the correlations of B-lines scores from extensive 28-sector and simplified 4-sector chest scan with EVLWI and PVPI derived from TPTD in the setting of intensive care unit (primary endpoint). Methods: We performed scoring of 28-sector and 4-sector B-Lines in 50 critically ill patients. TPTD was carried out with the PiCCO-2-device (Pulsion Medical Systems SE, Maquet Getinge Group). Median time exposure for ultrasound procedure was 12 minutes for 28-sector and 4 minutes for 4-sector scan. Results: Primarily, we found close correlations of 28-sector as well as 4-sector B-Lines scores with EVLWI (R 2 = 0.895 vs. R 2 = 0.880) and PVPI (R 2 = 0.760 vs. R 2 = 0.742). Both B-lines scores showed high accuracy to identify patients with specific levels of EVLWI and PVPI. The extensive 28-sector B-lines score revealed a moderate advantage compared to simplified 4-sector scan in detecting a normal EVLWI ≤ 7 (28-sector scan: sensitivity = 81.8%, specificity = 94.9%, AUC = 0.939 versus 4-sector scan: sensitivity = 81.8%, specificity = 82.1%, AUC = 0.902). Both protocols were approximately equivalent in prediction of lung edema with EVLWI ≥ 10 (28-sector scan: sensitivity = 88.9%, specificity = 95.7%, AUC = 0.977 versus 4-sector scan: sensitivity = 81.5%, specificity = 91.3%, AUC = 0.958) or severe pulmonary edema with EVLWI ≥ 15 (28-sector scan: sensitivity = 91.7%, specificity = 97.4%, AUC = 0.995 versus 4-sector scan: sensitivity = 91.7%, specificity = 92.1%, AUC = 0.978). As secondary endpoints, our evaluations resulted in significant associations of 28-sector as well as simplified 4-sector B-Lines score with parameters of respiratory function. Conclusion: Both B-line protocols provide accurate non-invasive evaluation of lung water in critically ill patients. The 28-sector scan offers a marginal advantage in prediction of pulmonary edema, but needs substantially more time than 4-sector scan. … (more)
- Is Part Of:
- Journal of intensive care medicine. Volume 37:Number 1(2022)
- Journal:
- Journal of intensive care medicine
- Issue:
- Volume 37:Number 1(2022)
- Issue Display:
- Volume 37, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 37
- Issue:
- 1
- Issue Sort Value:
- 2022-0037-0001-0000
- Page Start:
- 21
- Page End:
- 31
- Publication Date:
- 2022-01
- Subjects:
- lung ultrasound -- B-lines -- pulmonary edema -- extravascular lung water index (EVLWI) -- pulmonary vascular permeability index (PVPI) -- transpulmonary thermodilution (TPTD) -- acute respiratory distress syndrome (ARDS) -- intensive care unit (ICU)
Critical care medicine -- Periodicals
Critical Care -- Periodicals
Soins intensifs -- Périodiques
Soins intensifs
Périodique électronique (Descripteur de forme)
Ressource Internet (Descripteur de forme)
616.02805 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0885-0666;screen=info;ECOIP ↗
http://jic.sagepub.com ↗
http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=jic ↗
http://www.sagepublications.com/ ↗ - DOI:
- 10.1177/0885066620967655 ↗
- Languages:
- English
- ISSNs:
- 0885-0666
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17984.xml