Comparing the Efficacy of Radiation Free Machine-Vision Image-Guided Surgery With Traditional 2-Dimensional Fluoroscopy: A Randomized, Single-Center Study. Issue 3 (October 2021)
- Record Type:
- Journal Article
- Title:
- Comparing the Efficacy of Radiation Free Machine-Vision Image-Guided Surgery With Traditional 2-Dimensional Fluoroscopy: A Randomized, Single-Center Study. Issue 3 (October 2021)
- Main Title:
- Comparing the Efficacy of Radiation Free Machine-Vision Image-Guided Surgery With Traditional 2-Dimensional Fluoroscopy: A Randomized, Single-Center Study
- Authors:
- Dorilio, Jessica
Utah, Nicole
Dowe, Christina
Avrumova, Fedan
Alicea, Daniel
Brecevich, Antonio
Callanan, Tucker
Sama, Andrew
Lebl, Darren R.
Abjornson, Celeste
Cammisa, Frank P. - Other Names:
- Lebl Darren R. guest-editor.
Qureshi Sheeraz A. guest-editor. - Abstract:
- Background: Three-dimensional (3D) computer-assisted navigation (CAN) has emerged as a potential alternative to 2-dimensional (2D) fluoroscopy in the surgical placement of spinal instrumentation. Recently, 3D-CAN systems have improved significantly in their ability to provide real-time anatomical referencing while shortening the registration and set-up time. A novel system in navigation, Machine-Vision Image-Guided Surgery (MvIGS; 7D Surgical, Toronto, Canada) was cleared by the US Food and Drug Administration, but its potential benefits in reducing intra-operative radiation exposure to patients and enhancing surgical accuracy of pedicle screw placement are not fully known. Purpose : We sought to conduct a prospective, randomized, clinical study comparing the 3D-MvIGS spinal navigation system and 2D-fluoroscopy for pedicle screw insertion up to 3 levels (T10-S1) and for various measures of surgical efficacy. Methods : Sixty-two eligible patients were randomized to receive spine surgery using either the 3D-MvIGS group or the conventional 2D-fluoroscopy for pedicle screw fixation for the treatment of spinal stenosis and degenerative spondylolisthesis. Intra-operative parameters and procedure-related unintended protocol violations were recorded. Results : Operative time and estimated blood loss were not significantly different between groups. Radiation time and exposure to patients were significantly reduced in the 3D-MvIGS group. There was no difference between groups inBackground: Three-dimensional (3D) computer-assisted navigation (CAN) has emerged as a potential alternative to 2-dimensional (2D) fluoroscopy in the surgical placement of spinal instrumentation. Recently, 3D-CAN systems have improved significantly in their ability to provide real-time anatomical referencing while shortening the registration and set-up time. A novel system in navigation, Machine-Vision Image-Guided Surgery (MvIGS; 7D Surgical, Toronto, Canada) was cleared by the US Food and Drug Administration, but its potential benefits in reducing intra-operative radiation exposure to patients and enhancing surgical accuracy of pedicle screw placement are not fully known. Purpose : We sought to conduct a prospective, randomized, clinical study comparing the 3D-MvIGS spinal navigation system and 2D-fluoroscopy for pedicle screw insertion up to 3 levels (T10-S1) and for various measures of surgical efficacy. Methods : Sixty-two eligible patients were randomized to receive spine surgery using either the 3D-MvIGS group or the conventional 2D-fluoroscopy for pedicle screw fixation for the treatment of spinal stenosis and degenerative spondylolisthesis. Intra-operative parameters and procedure-related unintended protocol violations were recorded. Results : Operative time and estimated blood loss were not significantly different between groups. Radiation time and exposure to patients were significantly reduced in the 3D-MvIGS group. There was no difference between groups in pedicle screw placement accuracy (2D-fluoroscopy group, 96.6%; 3D-MvIGS group, 94.2%). There were no major complications or cases that required revision surgery. Conclusion : The 3D-MvIGS navigation system performed comparably with 2D-fluoroscopy in terms of pedicle screw placement accuracy and operative time. The 3D-MvIGS showed a significant reduction in radiation exposure to patients. In more complex cases or larger cohorts, the true value of greater anatomical visualization can be elucidated. … (more)
- Is Part Of:
- HSS journal. Volume 17:Issue 3(2021)
- Journal:
- HSS journal
- Issue:
- Volume 17:Issue 3(2021)
- Issue Display:
- Volume 17, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 17
- Issue:
- 3
- Issue Sort Value:
- 2021-0017-0003-0000
- Page Start:
- 274
- Page End:
- 280
- Publication Date:
- 2021-10
- Subjects:
- Imaging -- spine -- lumbar spine -- fusion -- operative treatments
Musculoskeletal system -- Surgery -- Periodicals
Orthopedic surgery -- Periodicals
Musculoskeletal System -- surgery -- Periodicals
Orthopedic Procedures -- Periodicals
Orthopédie -- Périodiques
Appareil locomoteur -- Maladies -- Périodiques
Appareil locomoteur -- Maladies -- Patients -- Réadaptation -- Périodiques
617.47005 - Journal URLs:
- http://www.ncbi.nlm.nih.gov/pmc/journals/593 ↗
http://www.springerlink.com/content/1556-3316/ ↗
http://www.springerlink.com/openurl.asp?genre=journal&issn=1556-3316 ↗
http://www.springer.com/gb/ ↗ - DOI:
- 10.1177/15563316211029837 ↗
- Languages:
- English
- ISSNs:
- 1556-3316
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4335.344650
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17980.xml