The Accuracy and Clinical Success of Robotic-Assisted Total Knee Arthroplasty. Issue 3 (October 2021)
- Record Type:
- Journal Article
- Title:
- The Accuracy and Clinical Success of Robotic-Assisted Total Knee Arthroplasty. Issue 3 (October 2021)
- Main Title:
- The Accuracy and Clinical Success of Robotic-Assisted Total Knee Arthroplasty
- Authors:
- Nickel, Brian T.
Carroll, Kaitlin M.
Pearle, Andrew D.
Kleeblad, Laura J.
Burger, Joost
Mayman, David J.
Westrich, Geoffrey
Jerabek, Seth A. - Other Names:
- Lebl Darren R. guest-editor.
Qureshi Sheeraz A. guest-editor. - Abstract:
- Background : Robotic-assisted total knee arthroplasty (rTKA) has emerged as a patient-specific customizable tool that enables 3-dimensional preoperative planning, intraoperative adjustment, robotic-assisted bone preparation, and soft-tissue protection. Haptic rTKA may enhance component positioning, but only a few small studies have examined patient satisfaction and clinical outcomes after haptic rTKA. Purpose : In patients who underwent haptic rTKA, we sought to evaluate (1) the discrepancy in alignment between the executed surgical plan and implanted alignment in the coronal and sagittal planes 1 year postoperatively and (2) patient-reported outcomes 2 years postoperatively. Methods : From a prospectively collected database, we reviewed 105 patients who underwent haptic rTKA from August 2016 to May 2017. Two fellowship-trained arthroplasty surgeons independently reviewed hip-to-ankle standing biplanar radiographs to measure overall limb alignment and individual tibial and femoral component alignment relative to the mechanical axis and compared this to the executed surgical plan. Patient-reported outcomes were collected preoperatively and at 2 years postoperatively using the Lower Activity Extremity Score (LEAS), Knee Injury and Osteoarthritis Outcome Score Junior (KOOS Jr.), and Numeric Pain Rating Scale (NPRS). Results : Mean patient age was 62.4 years, and mean body mass index was 30.6 kg/m 2 . Interobserver reliability was significant with a κ of 0.89. Absolute meanBackground : Robotic-assisted total knee arthroplasty (rTKA) has emerged as a patient-specific customizable tool that enables 3-dimensional preoperative planning, intraoperative adjustment, robotic-assisted bone preparation, and soft-tissue protection. Haptic rTKA may enhance component positioning, but only a few small studies have examined patient satisfaction and clinical outcomes after haptic rTKA. Purpose : In patients who underwent haptic rTKA, we sought to evaluate (1) the discrepancy in alignment between the executed surgical plan and implanted alignment in the coronal and sagittal planes 1 year postoperatively and (2) patient-reported outcomes 2 years postoperatively. Methods : From a prospectively collected database, we reviewed 105 patients who underwent haptic rTKA from August 2016 to May 2017. Two fellowship-trained arthroplasty surgeons independently reviewed hip-to-ankle standing biplanar radiographs to measure overall limb alignment and individual tibial and femoral component alignment relative to the mechanical axis and compared this to the executed surgical plan. Patient-reported outcomes were collected preoperatively and at 2 years postoperatively using the Lower Activity Extremity Score (LEAS), Knee Injury and Osteoarthritis Outcome Score Junior (KOOS Jr.), and Numeric Pain Rating Scale (NPRS). Results : Mean patient age was 62.4 years, and mean body mass index was 30.6 kg/m 2 . Interobserver reliability was significant with a κ of 0.89. Absolute mean deviations in postoperative coronal alignment compared to intraoperative alignment were 0.625° ± 0.70° and 0.45° ± 0.50° for the tibia and femur, respectively. Absolute mean deviations in postoperative tibial sagittal alignment were 0.47° ± 0.76°. Overall mechanical alignment was 0.97° ± 1.79°. Outcomes in LEAS, KOOS Jr., and NPRS changed from 8 to 10, 78 to 88.3, and 8 to 1, respectively. Conclusions : Haptic rTKA demonstrated high reliability and accuracy (less than 1°) of tibial coronal, femoral coronal, and tibial sagittal component alignment postoperatively compared to the surgical plan. Patient-reported outcomes improved, as well. A more rigorous study on long-term outcomes is warranted. … (more)
- Is Part Of:
- HSS journal. Volume 17:Issue 3(2021)
- Journal:
- HSS journal
- Issue:
- Volume 17:Issue 3(2021)
- Issue Display:
- Volume 17, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 17
- Issue:
- 3
- Issue Sort Value:
- 2021-0017-0003-0000
- Page Start:
- 261
- Page End:
- 266
- Publication Date:
- 2021-10
- Subjects:
- robotic-assisted -- total knee arthroplasty -- outcomes -- femoral component alignment -- tibial component alignment
Musculoskeletal system -- Surgery -- Periodicals
Orthopedic surgery -- Periodicals
Musculoskeletal System -- surgery -- Periodicals
Orthopedic Procedures -- Periodicals
Orthopédie -- Périodiques
Appareil locomoteur -- Maladies -- Périodiques
Appareil locomoteur -- Maladies -- Patients -- Réadaptation -- Périodiques
617.47005 - Journal URLs:
- http://www.ncbi.nlm.nih.gov/pmc/journals/593 ↗
http://www.springerlink.com/content/1556-3316/ ↗
http://www.springerlink.com/openurl.asp?genre=journal&issn=1556-3316 ↗
http://www.springer.com/gb/ ↗ - DOI:
- 10.1177/15563316211026307 ↗
- Languages:
- English
- ISSNs:
- 1556-3316
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4335.344650
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17980.xml