Using machine learning to predict post-operative depth of focus after cataract surgery with implantation of Tecnis Symfony. Issue 6 (November 2021)
- Record Type:
- Journal Article
- Title:
- Using machine learning to predict post-operative depth of focus after cataract surgery with implantation of Tecnis Symfony. Issue 6 (November 2021)
- Main Title:
- Using machine learning to predict post-operative depth of focus after cataract surgery with implantation of Tecnis Symfony
- Authors:
- Liu, Yang
Wei, David
Bai, Tao
Luo, Jie
Wood, Jennifer
Vashisht, Ashank
Zhang, Shumin
Xuan, Jianwei
Kattan, Michael
Coplan, Paul - Abstract:
- Objective: To predict post-operative depth of focus (DoF) using machine learning techniques after cataract surgery with Tecnis Symfony implantation and determine associated impact factors. Methods: This was a retrospective cohort study among patients receiving Tecnis Symfony implantation, an extended-range-of-vision intraocular lens, during October 2016–January 2020 at Daqing Oilfield General Hospital, China. Four different predictive models were used to predict good post-operative DoF (⩾2.5 D): Extreme Gradient Boost (XGBoost), random forest (RF), LASSO penalized regression, and multivariable logistic regression (MLR). Apriori algorithm was employed to further explore the association between patient attributes and DoF. Results: A total of 182 unique cases (143 patients) were included. The XGBoost model produced the best predictive accuracy compared to RF, LASSO, and MLR models. Overall performance of the best fitting XGBoost model was as follows: accuracy = 70.3%, AUC = 80.2%, sensitivity = 65.5%, and specificity = 87.5%. The Apriori algorithm identified six preoparative attributes with substantial effects on good post-operative DoF: low anterior chamber depth (ACD) (1.9 to <2.5 mm), smaller pupil size (1.7 to <2.5 mm), low-to-mid axial length (21 to <23 mm), minimum astigmatism degree (−0.2 to 0 diopter), low IOP (9 to <12 mmHg), and medium lens target refractive error (−0.5 to <−0.25 diopter). Conclusions: Machine Learning models were able to predict good post-operativeObjective: To predict post-operative depth of focus (DoF) using machine learning techniques after cataract surgery with Tecnis Symfony implantation and determine associated impact factors. Methods: This was a retrospective cohort study among patients receiving Tecnis Symfony implantation, an extended-range-of-vision intraocular lens, during October 2016–January 2020 at Daqing Oilfield General Hospital, China. Four different predictive models were used to predict good post-operative DoF (⩾2.5 D): Extreme Gradient Boost (XGBoost), random forest (RF), LASSO penalized regression, and multivariable logistic regression (MLR). Apriori algorithm was employed to further explore the association between patient attributes and DoF. Results: A total of 182 unique cases (143 patients) were included. The XGBoost model produced the best predictive accuracy compared to RF, LASSO, and MLR models. Overall performance of the best fitting XGBoost model was as follows: accuracy = 70.3%, AUC = 80.2%, sensitivity = 65.5%, and specificity = 87.5%. The Apriori algorithm identified six preoparative attributes with substantial effects on good post-operative DoF: low anterior chamber depth (ACD) (1.9 to <2.5 mm), smaller pupil size (1.7 to <2.5 mm), low-to-mid axial length (21 to <23 mm), minimum astigmatism degree (−0.2 to 0 diopter), low IOP (9 to <12 mmHg), and medium lens target refractive error (−0.5 to <−0.25 diopter). Conclusions: Machine Learning models were able to predict good post-operative DoF among cataract patients receiving a Tecnis Symfony ocular lens implantation. The accuracy of the model was above 70%. The Apriori algorithm identified six preoperative attributes with a strong association with post-operative DoF. … (more)
- Is Part Of:
- European journal of ophthalmology. Volume 31:Issue 6(2021)
- Journal:
- European journal of ophthalmology
- Issue:
- Volume 31:Issue 6(2021)
- Issue Display:
- Volume 31, Issue 6 (2021)
- Year:
- 2021
- Volume:
- 31
- Issue:
- 6
- Issue Sort Value:
- 2021-0031-0006-0000
- Page Start:
- 2938
- Page End:
- 2946
- Publication Date:
- 2021-11
- Subjects:
- Lens/cataract -- epidemiology/biostatistics -- IOLs -- biometry/axial length -- secondary IOL implantation
Ophthalmology -- Periodicals
Eye -- Diseases -- Periodicals
617.7005 - Journal URLs:
- http://www.uk.sagepub.com/home.nav ↗
http://www.eur-j-ophthalmol.com/Home/Index ↗
http://journals.sagepub.com/home/ejo ↗ - DOI:
- 10.1177/1120672121991777 ↗
- Languages:
- English
- ISSNs:
- 1120-6721
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17993.xml