Metal artifact reduction for flat panel detector intravenous CT angiography in patients with intracranial metallic implants after endovascular and surgical treatment. (7th September 2015)
- Record Type:
- Journal Article
- Title:
- Metal artifact reduction for flat panel detector intravenous CT angiography in patients with intracranial metallic implants after endovascular and surgical treatment. (7th September 2015)
- Main Title:
- Metal artifact reduction for flat panel detector intravenous CT angiography in patients with intracranial metallic implants after endovascular and surgical treatment
- Authors:
- Pjontek, Rastislav
Önenköprülü, Belgin
Scholz, Bernhard
Kyriakou, Yiannis
Schubert, Gerrit A
Nikoubashman, Omid
Othman, Ahmed
Wiesmann, Martin
Brockmann, Marc A - Abstract:
- Abstract : Background: Flat panel detector CT angiography with intravenous contrast agent injection (IV CTA) allows high-resolution imaging of cerebrovascular structures. Artifacts caused by metallic implants like platinum coils or clips lead to degradation of image quality and are a significant problem. Objective: To evaluate the influence of a prototype metal artifact reduction (MAR) algorithm on image quality in patients with intracranial metallic implants. Methods: Flat panel detector CT after intravenous application of 80 mL contrast agent was performed with an angiography system (Artis zee; Siemens, Forchheim, Germany) using a 20 s rotation protocol (200° rotation angle, 20 s acquisition time, 496 projections). The data before and after MAR of 26 patients with a total of 34 implants (coils, clips, stents) were independently evaluated by two blinded neuroradiologists. Results: MAR improved the assessability of the brain parenchyma and small vessels (diameter <1 mm) in the neighborhood of metallic implants and at a distance of 6 cm (p<0.001 each, Wilcoxon test). Furthermore, MAR significantly improved the assessability of parent vessel patency and potential aneurysm remnants (p<0.005 each, McNemar test). MAR, however, did not improve assessability of stented vessels. Conclusions: When an intravenous contrast protocol is used, MAR significantly ameliorates the assessability of brain parenchyma, vessels, and treated aneurysms in patients with intracranial coils or clips.
- Is Part Of:
- Journal of neurointerventional surgery. Volume 8:Number 8(2016)
- Journal:
- Journal of neurointerventional surgery
- Issue:
- Volume 8:Number 8(2016)
- Issue Display:
- Volume 8, Issue 8 (2016)
- Year:
- 2016
- Volume:
- 8
- Issue:
- 8
- Issue Sort Value:
- 2016-0008-0008-0000
- Page Start:
- 824
- Page End:
- 829
- Publication Date:
- 2015-09-07
- Subjects:
- CT Angiography -- CT -- Technology
Nervous system -- Surgery -- Periodicals
Cerebrovascular disease -- Surgery -- Periodicals
617.48 - Journal URLs:
- http://www.bmj.com/archive ↗
http://jnis.bmj.com/ ↗ - DOI:
- 10.1136/neurintsurg-2015-011787 ↗
- Languages:
- English
- ISSNs:
- 1759-8478
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17989.xml