Single-center experience of using high definition (Hi-Def) imaging during neurointervention treatment of intracranial aneurysms using flow diverters. (11th February 2020)
- Record Type:
- Journal Article
- Title:
- Single-center experience of using high definition (Hi-Def) imaging during neurointervention treatment of intracranial aneurysms using flow diverters. (11th February 2020)
- Main Title:
- Single-center experience of using high definition (Hi-Def) imaging during neurointervention treatment of intracranial aneurysms using flow diverters
- Authors:
- Setlur Nagesh, Swetadri Vasan
Vakharia, Kunal
Waqas, Muhammad
Munich, Stephan A
Bednarek, Daniel R
Davies, Jason M
Snyder, Kenneth V
Mokin, Maxim
Rudin, Stephen
Levy, Elad I
Siddiqui, Adnan H - Abstract:
- Abstract : Background: A new dual resolution imaging x-ray detector system (Canon Medical Systems Corporation, Tochigi, Japan) has a standard resolution 194 µm pixel conventional flat-panel detector (FPD) mode and a high-resolution 76 µm high-definition (Hi-Def) mode in a single unit. The Hi-Def mode enhances the visualization of the intravascular devices. Objective: We report the clinical experience and physician evaluation of this new detector system with Hi-Def mode for the treatment of intracranial aneurysms using a Pipeline embolization device (PED). Methods: During intervention at our institute, under large field of view (FOV) regular resolution FPD mode imaging, the catheter systems and devices were first guided to the proximity of the treatment area. Final placement and deployment of the PED was performed under Hi-Def mode guidance. A post-procedure 9-question physician survey was conducted to qualitatively assess the impact of Hi-Def mode visualization on physicians' intraoperative decision-making. One-sample t-test was performed on the responses from the survey. Dose values reported by the x-ray unit were also recorded. Results: Twenty-five cases were included in our study. The survey results indicated that, for each of the nine questions, the physicians in all cases indicated that the Hi-Def mode improved visualization compared with the FPD mode. For the 25 cases, the mean cumulative entrance air kerma was 2.35 Gy, the mean dose area product (DAP) was 173.71 Gy.cmAbstract : Background: A new dual resolution imaging x-ray detector system (Canon Medical Systems Corporation, Tochigi, Japan) has a standard resolution 194 µm pixel conventional flat-panel detector (FPD) mode and a high-resolution 76 µm high-definition (Hi-Def) mode in a single unit. The Hi-Def mode enhances the visualization of the intravascular devices. Objective: We report the clinical experience and physician evaluation of this new detector system with Hi-Def mode for the treatment of intracranial aneurysms using a Pipeline embolization device (PED). Methods: During intervention at our institute, under large field of view (FOV) regular resolution FPD mode imaging, the catheter systems and devices were first guided to the proximity of the treatment area. Final placement and deployment of the PED was performed under Hi-Def mode guidance. A post-procedure 9-question physician survey was conducted to qualitatively assess the impact of Hi-Def mode visualization on physicians' intraoperative decision-making. One-sample t-test was performed on the responses from the survey. Dose values reported by the x-ray unit were also recorded. Results: Twenty-five cases were included in our study. The survey results indicated that, for each of the nine questions, the physicians in all cases indicated that the Hi-Def mode improved visualization compared with the FPD mode. For the 25 cases, the mean cumulative entrance air kerma was 2.35 Gy, the mean dose area product (DAP) was 173.71 Gy.cm 2, and the mean x-ray exposure time was 39.30 min. Conclusions: The Hi-Def mode improves visualization of flow diverters and may help in achieving more accurate placement and deployment of devices. … (more)
- Is Part Of:
- Journal of neurointerventional surgery. Volume 12:Number 9(2020)
- Journal:
- Journal of neurointerventional surgery
- Issue:
- Volume 12:Number 9(2020)
- Issue Display:
- Volume 12, Issue 9 (2020)
- Year:
- 2020
- Volume:
- 12
- Issue:
- 9
- Issue Sort Value:
- 2020-0012-0009-0000
- Page Start:
- 897
- Page End:
- 901
- Publication Date:
- 2020-02-11
- Subjects:
- aneurysm -- pipeline embolization device -- resolution -- physician survey -- zoom -- endovascular
Nervous system -- Surgery -- Periodicals
Cerebrovascular disease -- Surgery -- Periodicals
617.48 - Journal URLs:
- http://www.bmj.com/archive ↗
http://jnis.bmj.com/ ↗ - DOI:
- 10.1136/neurintsurg-2019-015551 ↗
- Languages:
- English
- ISSNs:
- 1759-8478
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17981.xml