A novel Hausdorff distance based restrain criterion for zero-sequence differential protection of converter transformer. (February 2019)
- Record Type:
- Journal Article
- Title:
- A novel Hausdorff distance based restrain criterion for zero-sequence differential protection of converter transformer. (February 2019)
- Main Title:
- A novel Hausdorff distance based restrain criterion for zero-sequence differential protection of converter transformer
- Authors:
- Ding, Suyang
Lin, Xiangning
Zhang, Zheyuan
Li, Zhengtian
Chen, Le
Weng, Hanli - Abstract:
- Highlights: The magnetic bias accumulation and saturation of CT in neutral point in the core of converter transformer is analyzed in this paper. The phase and harmonic characteristics of wave shapes at both end of zero-sequence differential protection is utilized to identify the external fault removal and the true internal fault. An additional restraint criterion for zero-sequence differential protection, which can be applied to identify various inrush conditions including fault recovery inrush, is proposed in this paper. Abstract: Due to its high sensitivity and fast operation rapidity, zero-sequence differential protection (ZSDP) has become the most frequently used main protection for EHV and UHV power transformers. It is generally assumed that extra restrain criterion is unnecessary for ZSDP since it is immune to the magnetizing inrush current in theory. However, it's found that the bias of zero sequence current in converter transformer due to core saturation may lead to the accumulation of magnetic bias within the core of CT, especially during external fault removal period. This may lead to the mal-operation of ZSDP. Based on the Hausdorff graphics recognition algorithm, an extra restrain criterion for ZSDP is proposed in this paper. Verified by simulation and theoretical analysis, the proposed criterion will not influence the performance of traditional ZSDP. However, the proposed criterion can correctly identify the fake differential current and effectively prevent theHighlights: The magnetic bias accumulation and saturation of CT in neutral point in the core of converter transformer is analyzed in this paper. The phase and harmonic characteristics of wave shapes at both end of zero-sequence differential protection is utilized to identify the external fault removal and the true internal fault. An additional restraint criterion for zero-sequence differential protection, which can be applied to identify various inrush conditions including fault recovery inrush, is proposed in this paper. Abstract: Due to its high sensitivity and fast operation rapidity, zero-sequence differential protection (ZSDP) has become the most frequently used main protection for EHV and UHV power transformers. It is generally assumed that extra restrain criterion is unnecessary for ZSDP since it is immune to the magnetizing inrush current in theory. However, it's found that the bias of zero sequence current in converter transformer due to core saturation may lead to the accumulation of magnetic bias within the core of CT, especially during external fault removal period. This may lead to the mal-operation of ZSDP. Based on the Hausdorff graphics recognition algorithm, an extra restrain criterion for ZSDP is proposed in this paper. Verified by simulation and theoretical analysis, the proposed criterion will not influence the performance of traditional ZSDP. However, the proposed criterion can correctly identify the fake differential current and effectively prevent the mal-operation of ZSDP caused by the recovery inrush. … (more)
- Is Part Of:
- International journal of electrical power & energy systems. Volume 105(2019)
- Journal:
- International journal of electrical power & energy systems
- Issue:
- Volume 105(2019)
- Issue Display:
- Volume 105, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 105
- Issue:
- 2019
- Issue Sort Value:
- 2019-0105-2019-0000
- Page Start:
- 753
- Page End:
- 764
- Publication Date:
- 2019-02
- Subjects:
- Zero-sequence differential protection -- Recovery inrush -- CT saturation -- Mal-operation -- Hausdorff distance -- Waveform comparison
Electrical engineering -- Periodicals
Electric power systems -- Periodicals
Électrotechnique -- Périodiques
Réseaux électriques (Énergie) -- Périodiques
Electric power systems
Electrical engineering
Periodicals
621.3 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01420615 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijepes.2018.08.046 ↗
- Languages:
- English
- ISSNs:
- 0142-0615
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.220000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17946.xml