Automated deep-learning system for Gleason grading of prostate cancer using biopsies: a diagnostic study. Issue 2 (February 2020)
- Record Type:
- Journal Article
- Title:
- Automated deep-learning system for Gleason grading of prostate cancer using biopsies: a diagnostic study. Issue 2 (February 2020)
- Main Title:
- Automated deep-learning system for Gleason grading of prostate cancer using biopsies: a diagnostic study
- Authors:
- Bulten, Wouter
Pinckaers, Hans
van Boven, Hester
Vink, Robert
de Bel, Thomas
van Ginneken, Bram
van der Laak, Jeroen
Hulsbergen-van de Kaa, Christina
Litjens, Geert - Abstract:
- Summary: Background: The Gleason score is the strongest correlating predictor of recurrence for prostate cancer, but has substantial inter-observer variability, limiting its usefulness for individual patients. Specialised urological pathologists have greater concordance; however, such expertise is not widely available. Prostate cancer diagnostics could thus benefit from robust, reproducible Gleason grading. We aimed to investigate the potential of deep learning to perform automated Gleason grading of prostate biopsies. Methods: In this retrospective study, we developed a deep-learning system to grade prostate biopsies following the Gleason grading standard. The system was developed using randomly selected biopsies, sampled by the biopsy Gleason score, from patients at the Radboud University Medical Center (pathology report dated between Jan 1, 2012, and Dec 31, 2017). A semi-automatic labelling technique was used to circumvent the need for manual annotations by pathologists, using pathologists' reports as the reference standard during training. The system was developed to delineate individual glands, assign Gleason growth patterns, and determine the biopsy-level grade. For validation of the method, a consensus reference standard was set by three expert urological pathologists on an independent test set of 550 biopsies. Of these 550, 100 were used in an observer experiment, in which the system, 13 pathologists, and two pathologists in training were compared with respect toSummary: Background: The Gleason score is the strongest correlating predictor of recurrence for prostate cancer, but has substantial inter-observer variability, limiting its usefulness for individual patients. Specialised urological pathologists have greater concordance; however, such expertise is not widely available. Prostate cancer diagnostics could thus benefit from robust, reproducible Gleason grading. We aimed to investigate the potential of deep learning to perform automated Gleason grading of prostate biopsies. Methods: In this retrospective study, we developed a deep-learning system to grade prostate biopsies following the Gleason grading standard. The system was developed using randomly selected biopsies, sampled by the biopsy Gleason score, from patients at the Radboud University Medical Center (pathology report dated between Jan 1, 2012, and Dec 31, 2017). A semi-automatic labelling technique was used to circumvent the need for manual annotations by pathologists, using pathologists' reports as the reference standard during training. The system was developed to delineate individual glands, assign Gleason growth patterns, and determine the biopsy-level grade. For validation of the method, a consensus reference standard was set by three expert urological pathologists on an independent test set of 550 biopsies. Of these 550, 100 were used in an observer experiment, in which the system, 13 pathologists, and two pathologists in training were compared with respect to the reference standard. The system was also compared to an external test dataset of 886 cores, which contained 245 cores from a different centre that were independently graded by two pathologists. Findings: We collected 5759 biopsies from 1243 patients. The developed system achieved a high agreement with the reference standard (quadratic Cohen's kappa 0·918, 95% CI 0·891–0·941) and scored highly at clinical decision thresholds: benign versus malignant (area under the curve 0·990, 95% CI 0·982–0·996), grade group of 2 or more (0·978, 0·966–0·988), and grade group of 3 or more (0·974, 0·962–0·984). In an observer experiment, the deep-learning system scored higher (kappa 0·854) than the panel (median kappa 0·819), outperforming 10 of 15 pathologist observers. On the external test dataset, the system obtained a high agreement with the reference standard set independently by two pathologists (quadratic Cohen's kappa 0·723 and 0·707) and within inter-observer variability (kappa 0·71). Interpretation: Our automated deep-learning system achieved a performance similar to pathologists for Gleason grading and could potentially contribute to prostate cancer diagnosis. The system could potentially assist pathologists by screening biopsies, providing second opinions on grade group, and presenting quantitative measurements of volume percentages. Funding: Dutch Cancer Society. … (more)
- Is Part Of:
- Lancet oncology. Volume 21:Issue 2(2020)
- Journal:
- Lancet oncology
- Issue:
- Volume 21:Issue 2(2020)
- Issue Display:
- Volume 21, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 21
- Issue:
- 2
- Issue Sort Value:
- 2020-0021-0002-0000
- Page Start:
- 233
- Page End:
- 241
- Publication Date:
- 2020-02
- Subjects:
- Oncology -- Periodicals
Neoplasms -- Periodicals
Cancérologie -- Périodiques
Oncologie
Oncology
Periodicals
Electronic journals
616.994005 - Journal URLs:
- http://www.sciencedirect.com/science/journal/14702045 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/S1470-2045(19)30739-9 ↗
- Languages:
- English
- ISSNs:
- 1470-2045
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5146.090000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 17967.xml