Dynamic simulation of an air-source heat pump water heater using novel modified evaporator model. (5th November 2018)
- Record Type:
- Journal Article
- Title:
- Dynamic simulation of an air-source heat pump water heater using novel modified evaporator model. (5th November 2018)
- Main Title:
- Dynamic simulation of an air-source heat pump water heater using novel modified evaporator model
- Authors:
- Chen, Jiaheng
Yu, Jianlin - Abstract:
- Highlights: A modified evaporator model is developed to eliminate the mass conservation error. The modified model can achieve higher accuracy compared with common model. The transient responses of the modified model and experimental data match well. The effects of the evaporator air velocity and compressor frequency are evaluated. Abstract: Currently, the common evaporator model based on the moving boundary method ignores the inlet specific enthalpy time derivative, and then yields a mass conservation error in the calculation, which may further reduce the dynamic simulation precision of the evaporator and whole system. To solve this problem, the common evaporator model is modified by introducing an additional input variable, i.e. evaporator inlet specific enthalpy time derivative. The computational results indicate that the modified evaporator model can perfectly eliminate the mass conservation error compared to the common evaporator model. The simulation results based on the common model and the modified model are compared with the experimental data, which reveals that the results from the modified model have better agreement with the experimental data. Under the considered condition, the modified model can reduce the simulation error of average heating capacity from 8.61% to 3.82% compared with the common model. The transient response of the modified model to the step change of the EEV opening degree is also verified with the test. And both the response speeds andHighlights: A modified evaporator model is developed to eliminate the mass conservation error. The modified model can achieve higher accuracy compared with common model. The transient responses of the modified model and experimental data match well. The effects of the evaporator air velocity and compressor frequency are evaluated. Abstract: Currently, the common evaporator model based on the moving boundary method ignores the inlet specific enthalpy time derivative, and then yields a mass conservation error in the calculation, which may further reduce the dynamic simulation precision of the evaporator and whole system. To solve this problem, the common evaporator model is modified by introducing an additional input variable, i.e. evaporator inlet specific enthalpy time derivative. The computational results indicate that the modified evaporator model can perfectly eliminate the mass conservation error compared to the common evaporator model. The simulation results based on the common model and the modified model are compared with the experimental data, which reveals that the results from the modified model have better agreement with the experimental data. Under the considered condition, the modified model can reduce the simulation error of average heating capacity from 8.61% to 3.82% compared with the common model. The transient response of the modified model to the step change of the EEV opening degree is also verified with the test. And both the response speeds and numerical values of the evaporating pressure and refrigerant mass flow rate show good agreement. The effects of the evaporator air velocity and the compressor frequency on the system performance are theoretically investigated based on the modified model. The increase of the evaporator air velocity always contributes to the performance improvement of the whole system, but this positive effect become very small when the air velocity exceeds 3 m/s. As the compressor frequency increases from 40 Hz to 60 Hz, the average heating capacity and power consumption increase by 39.62% and 9.79%, respectively. … (more)
- Is Part Of:
- Applied thermal engineering. Volume 144(2018)
- Journal:
- Applied thermal engineering
- Issue:
- Volume 144(2018)
- Issue Display:
- Volume 144, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 144
- Issue:
- 2018
- Issue Sort Value:
- 2018-0144-2018-0000
- Page Start:
- 469
- Page End:
- 478
- Publication Date:
- 2018-11-05
- Subjects:
- Modified evaporator model -- Experimental verification -- Dynamic simulation -- Heat pump
Heat engineering -- Periodicals
Heating -- Equipment and supplies -- Periodicals
Periodicals
621.40205 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13594311 ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.applthermaleng.2018.08.085 ↗
- Languages:
- English
- ISSNs:
- 1359-4311
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1580.101000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17969.xml