Universal and reusable hapten/antibody-mediated portable optofluidic immunosensing platform for rapid on-site detection of pathogens. (November 2018)
- Record Type:
- Journal Article
- Title:
- Universal and reusable hapten/antibody-mediated portable optofluidic immunosensing platform for rapid on-site detection of pathogens. (November 2018)
- Main Title:
- Universal and reusable hapten/antibody-mediated portable optofluidic immunosensing platform for rapid on-site detection of pathogens
- Authors:
- Zhou, Liping
Fang, Shunyan
Liu, Yanping
Yang, Rong
Song, Dan
Long, Feng
Zhu, Anna - Abstract:
- Abstract: A universal and reusable hapten–antibody-mediated portable optofluidic immunosensing platform (OIP) was developed for rapid on-site detection of pathogens. By using Escherichia coli O157:H7 ( E. coli O157:H7) and bisphenol A-Bovine serum albumin (BPA-BSA)/anti-BPA antibody as a model pathogen and a mediated hapten–antibody, respectively, a novel immunoassay mechanism was proposed to detect pathogens. The BPA-BSA-modified immunosensor and E. coli O157:H7 were initially saturated with anti-BPA antibodies (mouse IgG) and anti- E. coli O157:H7 antibodies (mouse IgG), respectively. Then, the fluorescence-labeled secondary antibodies (goat anti-mouse IgG antibody) were incubated with E. coli O157:H7 with their antibodies. Next, the mixture was introduced into the immunosensor surface bound to the anti-BPA antibodies. A high concentration of E. coli O157:H7 in the sample reduced the number of fluorescence-labeled secondary antibodies bound to the immunosensor surface, thus resulting in the detection of low fluorescence signals. Under optimized conditions, the hapten–antibody-mediated OIP system exhibited a detection limit of 8 cfu/mL E. coli O157:H7 after concentrating 100 times by using centrifugation, and a test cycle, including prereaction, detection, and regeneration, was less than 1 h. The robustness of the hapten–carrier protein-modified immunosensor surface allowed multiple pathogen immunoassays. The proposed strategy demonstrated good recovery, precision, andAbstract: A universal and reusable hapten–antibody-mediated portable optofluidic immunosensing platform (OIP) was developed for rapid on-site detection of pathogens. By using Escherichia coli O157:H7 ( E. coli O157:H7) and bisphenol A-Bovine serum albumin (BPA-BSA)/anti-BPA antibody as a model pathogen and a mediated hapten–antibody, respectively, a novel immunoassay mechanism was proposed to detect pathogens. The BPA-BSA-modified immunosensor and E. coli O157:H7 were initially saturated with anti-BPA antibodies (mouse IgG) and anti- E. coli O157:H7 antibodies (mouse IgG), respectively. Then, the fluorescence-labeled secondary antibodies (goat anti-mouse IgG antibody) were incubated with E. coli O157:H7 with their antibodies. Next, the mixture was introduced into the immunosensor surface bound to the anti-BPA antibodies. A high concentration of E. coli O157:H7 in the sample reduced the number of fluorescence-labeled secondary antibodies bound to the immunosensor surface, thus resulting in the detection of low fluorescence signals. Under optimized conditions, the hapten–antibody-mediated OIP system exhibited a detection limit of 8 cfu/mL E. coli O157:H7 after concentrating 100 times by using centrifugation, and a test cycle, including prereaction, detection, and regeneration, was less than 1 h. The robustness of the hapten–carrier protein-modified immunosensor surface allowed multiple pathogen immunoassays. The proposed strategy demonstrated good recovery, precision, and accuracy through the evaluation of the spiked water samples. We expect that the new platform can be readily used for the detection of other pathogens in a variety of application fields ranging from environmental monitoring and food safety to medical diagnosis. Graphical abstract: Image 1 Highlights: Universal and reusable OIP was developed for rapid on-site detection of pathogens. Hapten–antibody-mediated immunoassay mechanism was proposed to detect pathogens. The OIP exhibits a LOD of 8 cfu/mL E. coli O157:H7, and a test cycle was <1 h. The hapten–modified immunosensor surface allowed multiple pathogen immunoassays. The OIP is a promising alternative to conventional pathogen detection methods. … (more)
- Is Part Of:
- Chemosphere. Volume 210(2018)
- Journal:
- Chemosphere
- Issue:
- Volume 210(2018)
- Issue Display:
- Volume 210, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 210
- Issue:
- 2018
- Issue Sort Value:
- 2018-0210-2018-0000
- Page Start:
- 10
- Page End:
- 18
- Publication Date:
- 2018-11
- Subjects:
- Pathogen -- Optofluidics -- Immunosensor -- E. coli O157:H7 -- Immunoassay
Pollution -- Periodicals
Pollution -- Physiological effect -- Periodicals
Environmental sciences -- Periodicals
Atmospheric chemistry -- Periodicals
551.511 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00456535/ ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.chemosphere.2018.06.159 ↗
- Languages:
- English
- ISSNs:
- 0045-6535
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3172.280000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 17912.xml