Evaluation of two internal fixation techniques for mandibular parasymphyseal fractures comparing conventional titanium miniplates with customised titanium CRB omega miniplates: a prospective study. Issue 6 (July 2018)
- Record Type:
- Journal Article
- Title:
- Evaluation of two internal fixation techniques for mandibular parasymphyseal fractures comparing conventional titanium miniplates with customised titanium CRB omega miniplates: a prospective study. Issue 6 (July 2018)
- Main Title:
- Evaluation of two internal fixation techniques for mandibular parasymphyseal fractures comparing conventional titanium miniplates with customised titanium CRB omega miniplates: a prospective study
- Authors:
- Bande, C.R.
Kurawar, K.R.
Mishra, A.
Joshi, A.
Goel, M.
Mahajan, M.R. - Abstract:
- Abstract: Our aim was to compare the efficacy and outcome of customised, titanium, CRB (Chandrashekhar Rushiji Bande), omega miniplates with those of conventional titanium miniplates in the management of parasymphyseal fractures of the mandible, with or without involvement of the mental nerve, after clinical and radiographic evaluation. A total of 252 parasymphyseal fractures in 200 patients were selected for the study over the period of seven years (January 2010–January2017) and divided randomly into two groups. The first group included 126 fractures treated with two conventional titanium miniplates (conventional group) and the second 126 fractures treated with one customised, titanium, CRB, omega miniplate (customised group). All operations were done by the same surgeon. Duration of operation (from placement of incision to closure of the defect) was recorded. Postoperative paraesthesia, infection, and acceptability of the plate to patients were also recorded. Postoperative healing was evaluated radiologically at one week and six months postoperatively. Operations were significantly shorter, and significantly fewer patients developed paraesthesia or infection, in the customised group. These patients were also happier with their miniplates, and had good radiological bony healing. In conclusion, a single customised, titanium, CRB, omega miniplate is an effective and economical alternative to two conventional titanium miniplates in the management of parasymphysis fractures ofAbstract: Our aim was to compare the efficacy and outcome of customised, titanium, CRB (Chandrashekhar Rushiji Bande), omega miniplates with those of conventional titanium miniplates in the management of parasymphyseal fractures of the mandible, with or without involvement of the mental nerve, after clinical and radiographic evaluation. A total of 252 parasymphyseal fractures in 200 patients were selected for the study over the period of seven years (January 2010–January2017) and divided randomly into two groups. The first group included 126 fractures treated with two conventional titanium miniplates (conventional group) and the second 126 fractures treated with one customised, titanium, CRB, omega miniplate (customised group). All operations were done by the same surgeon. Duration of operation (from placement of incision to closure of the defect) was recorded. Postoperative paraesthesia, infection, and acceptability of the plate to patients were also recorded. Postoperative healing was evaluated radiologically at one week and six months postoperatively. Operations were significantly shorter, and significantly fewer patients developed paraesthesia or infection, in the customised group. These patients were also happier with their miniplates, and had good radiological bony healing. In conclusion, a single customised, titanium, CRB, omega miniplate is an effective and economical alternative to two conventional titanium miniplates in the management of parasymphysis fractures of the mandible. … (more)
- Is Part Of:
- British journal of oral and maxillofacial surgery. Volume 56:Issue 6(2018)
- Journal:
- British journal of oral and maxillofacial surgery
- Issue:
- Volume 56:Issue 6(2018)
- Issue Display:
- Volume 56, Issue 6 (2018)
- Year:
- 2018
- Volume:
- 56
- Issue:
- 6
- Issue Sort Value:
- 2018-0056-0006-0000
- Page Start:
- 520
- Page End:
- 524
- Publication Date:
- 2018-07
- Subjects:
- Customised Titanium CRB Omega Miniplate -- Conventional titanium miniplate -- parasymphysis fracture -- mental nerve
Mouth -- Surgery -- Periodicals
Maxilla -- Surgery -- Periodicals
Face -- Surgery -- Periodicals
Surgery, Plastic -- Periodicals
Dentistry, Operative -- Periodicals
Face -- surgery -- Periodicals
Mouth -- surgery -- Periodicals
Maxilla -- surgery -- Periodicals
Surgery, Oral -- Periodicals
Oral Surgical Procedures -- Periodicals
Dentistry, Operative -- Periodicals
Bouche -- Chirurgie -- Périodiques
Maxillaire supérieur -- Chirurgie -- Périodiques
Face -- Chirurgie -- Périodiques
Chirurgie dentaire -- Périodiques
Dentistry, Operative
Face -- Surgery
Maxilla -- Surgery
Mouth -- Surgery
Surgery, Plastic
Electronic journals
Periodicals
617.52059 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02664356 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.bjoms.2018.05.004 ↗
- Languages:
- English
- ISSNs:
- 0266-4356
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2314.200000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17905.xml