134 SENSITIVITY OF ACTIVATED PARTIAL THROMBOPLASTIN TIME FOR LUPUS ANTICOAGULANT DONE BY ACTIN FSL (DADE) AND THROMBOSIL (HEMOLIANCE). (10th December 2015)
- Record Type:
- Journal Article
- Title:
- 134 SENSITIVITY OF ACTIVATED PARTIAL THROMBOPLASTIN TIME FOR LUPUS ANTICOAGULANT DONE BY ACTIN FSL (DADE) AND THROMBOSIL (HEMOLIANCE). (10th December 2015)
- Main Title:
- 134 SENSITIVITY OF ACTIVATED PARTIAL THROMBOPLASTIN TIME FOR LUPUS ANTICOAGULANT DONE BY ACTIN FSL (DADE) AND THROMBOSIL (HEMOLIANCE)
- Authors:
- Razaq, M.
Mankan, N.
Puskur, B.
Mahajan, N.
Hussain, S. - Abstract:
- Abstract : Background: Lupus anticoagulant (LA) are antibodies that interfere with phospholipids in phospholipid-based tests such a activated partial thromboplastin time (aPTT), prothrombin time (PT), and dilute Russell viper venom time (DRVVT). No single test is 100% effective in ruling in or out the presence of LA. Actin FSL and thrombosil are considered relatively LA-sensitive aPTT reagents. But normal aPTT by these reagents does not exclude the presence of LA. LAs do not inhibit the action of platelet phospholipids, so platelet poor plasma should be used to increase the sensitivity for LA. However, in routine coagulation tests laboratories use platelet-rich plasma to do aPTT. In our hospital, the regular laboratory uses Actin FSL (Dade) and the special hematology laboratory uses thrombosil (Hemoliance) to perform aPTT. We test for LA if aPTT remains prolonged on mixing studies or as a part of hypercoaguable workup for a patient with thrombotic episodes. We did a retrospective study to see the sensitivity of these tests performed in platelet-rich plasma in ruling out LAs. Method: Retrospective chart review of all the patients diagnosed with lupus anticoagulant at Coney Island from February to January 2004. Information regarding patients' age, sex, laboratory data, and history of any thromboembolic phenomenon was collected. LA was diagnosed with DRVVT. aPTT in these patients was done as a part of routine coagulation screening on platelet-rich plasma. Results: 58 patientsAbstract : Background: Lupus anticoagulant (LA) are antibodies that interfere with phospholipids in phospholipid-based tests such a activated partial thromboplastin time (aPTT), prothrombin time (PT), and dilute Russell viper venom time (DRVVT). No single test is 100% effective in ruling in or out the presence of LA. Actin FSL and thrombosil are considered relatively LA-sensitive aPTT reagents. But normal aPTT by these reagents does not exclude the presence of LA. LAs do not inhibit the action of platelet phospholipids, so platelet poor plasma should be used to increase the sensitivity for LA. However, in routine coagulation tests laboratories use platelet-rich plasma to do aPTT. In our hospital, the regular laboratory uses Actin FSL (Dade) and the special hematology laboratory uses thrombosil (Hemoliance) to perform aPTT. We test for LA if aPTT remains prolonged on mixing studies or as a part of hypercoaguable workup for a patient with thrombotic episodes. We did a retrospective study to see the sensitivity of these tests performed in platelet-rich plasma in ruling out LAs. Method: Retrospective chart review of all the patients diagnosed with lupus anticoagulant at Coney Island from February to January 2004. Information regarding patients' age, sex, laboratory data, and history of any thromboembolic phenomenon was collected. LA was diagnosed with DRVVT. aPTT in these patients was done as a part of routine coagulation screening on platelet-rich plasma. Results: 58 patients (25 females and 35 males) with age ranging from 26 to 80 years were diagnosed with LA by DRVVT. 57 patients had aPTT done by Actin FSL. 32 of them had elevated aPTT (range 24-79.6) with a sensitivity of 56%. 57 patients had aPTT done by thrombosil. 19 of them had elevated aPTT (range 23.7-67) with a sensitivity of 33%. 55 patients had aPTT done by both reagents and 38 of them had at least one elevated aPTT with a sensitivity of 69%. Conclusion: Normal aPTT done on platelet-rich plasma as a part of coagulation screening does not exclude the presence of LA. In our study the sensitivity of both the reagents individually as well as combined was very low, although Actin FSL was found to be more sensitive than Hemoliance. … (more)
- Is Part Of:
- Journal of investigative medicine. Volume 53:Number 1(2005)
- Journal:
- Journal of investigative medicine
- Issue:
- Volume 53:Number 1(2005)
- Issue Display:
- Volume 53, Issue 1 (2005)
- Year:
- 2005
- Volume:
- 53
- Issue:
- 1
- Issue Sort Value:
- 2005-0053-0001-0000
- Page Start:
- S276
- Page End:
- S277
- Publication Date:
- 2015-12-10
- Subjects:
- Clinical medicine -- Periodicals
Medicine -- Research -- Periodicals
Medicine
Research -- United States
Clinical medicine
Medicine -- Research
Periodicals
616.075 - Journal URLs:
- http://journals.lww.com/jinvestigativemed/pages/default.aspx ↗
http://jim.bmj.com/ ↗
https://journals.sagepub.com/home/IMJ ↗
http://journals.lww.com ↗ - DOI:
- 10.2310/6650.2005.00006.133 ↗
- Languages:
- English
- ISSNs:
- 1081-5589
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5008.010000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 17899.xml