PP13 The NHS pathways (NHSP) medical call triage system and new 'nature of call' telephone screening tool, employed prior to NHSP, can accurately identify high acuity patients: analysis of sensitivity and specificity using routine ambulance service data. Issue 1 (14th January 2019)
- Record Type:
- Journal Article
- Title:
- PP13 The NHS pathways (NHSP) medical call triage system and new 'nature of call' telephone screening tool, employed prior to NHSP, can accurately identify high acuity patients: analysis of sensitivity and specificity using routine ambulance service data. Issue 1 (14th January 2019)
- Main Title:
- PP13 The NHS pathways (NHSP) medical call triage system and new 'nature of call' telephone screening tool, employed prior to NHSP, can accurately identify high acuity patients: analysis of sensitivity and specificity using routine ambulance service data
- Authors:
- Green, Jonathan
Ewings, Sean
Wortham, Richard
Walsh, Bronagh - Abstract:
- Abstract : Background: The NHS Pathways (NHSP) medical call triage system is employed by UK ambulance services. One function is to identify a broad category of 'high-acuity calls', distinguishing them from those that do not require an emergency response. A new pre-triage screening tool, Nature of Call (NoC), designed to augment NHSP could be employed as a rapid initial sieve of broad acuity. Objectives: To identify the accuracy of NHSP (and NoC) in recognising patients who require an emergency ambulance response (and therefore those who may not). Methods: Diagnostic accuracy. The sample is a retrospective cohort of consecutive calls, over a 4 month period, to a UK ambulance service. Sensitivity and specificity were determined, comparing allocated NoC and NHS Pathways priority dispositions with a composite reference standard comprised of administered medications, procedures, observations and clinical impressions associated with high-acuity, as recorded on ambulance electronic Patient Clinical Records. Results: A total of 1 87 408 emergency calls were received. Of these, 71 373 were allocated both NoC and NHSP priority dispositions and were associated with electronic Patient Clinical Records. 40 997 (57%) of these patients met the high-acuity reference criteria. NHSP, sensitivity=98.1% (95% CI 98.0 to 98.2); specificity=5.9% (95% CI 5.6 to 6.1). NoC, sensitivity=84.0% (95% CI 83.7 to 84.4); specificity=26.5% (95% CI 26.0 to 27.0). Conclusions: NHSP is effective in identifyingAbstract : Background: The NHS Pathways (NHSP) medical call triage system is employed by UK ambulance services. One function is to identify a broad category of 'high-acuity calls', distinguishing them from those that do not require an emergency response. A new pre-triage screening tool, Nature of Call (NoC), designed to augment NHSP could be employed as a rapid initial sieve of broad acuity. Objectives: To identify the accuracy of NHSP (and NoC) in recognising patients who require an emergency ambulance response (and therefore those who may not). Methods: Diagnostic accuracy. The sample is a retrospective cohort of consecutive calls, over a 4 month period, to a UK ambulance service. Sensitivity and specificity were determined, comparing allocated NoC and NHS Pathways priority dispositions with a composite reference standard comprised of administered medications, procedures, observations and clinical impressions associated with high-acuity, as recorded on ambulance electronic Patient Clinical Records. Results: A total of 1 87 408 emergency calls were received. Of these, 71 373 were allocated both NoC and NHSP priority dispositions and were associated with electronic Patient Clinical Records. 40 997 (57%) of these patients met the high-acuity reference criteria. NHSP, sensitivity=98.1% (95% CI 98.0 to 98.2); specificity=5.9% (95% CI 5.6 to 6.1). NoC, sensitivity=84.0% (95% CI 83.7 to 84.4); specificity=26.5% (95% CI 26.0 to 27.0). Conclusions: NHSP is effective in identifying high-acuity patients (as is NoC). Sensitivity analysis therefore supports the this function of NHSP and NoC/NHSP to inform initial ambulance dispatch decisions, particularly if NoC categorisation is reviewed in the light of subsequent NHSP triage. However, both systems appear to achieve high sensitivity by also allocating most low-acuity calls to high-acuity categories. This significantly restricts operational application. Only one quarter of low-acuity calls are allocated the lowest priority category by NoC and one-in-seventeen by NHSP, severely restricting the group likely to be considered for alternative care pathways. … (more)
- Is Part Of:
- Emergency medicine journal. Volume 36:Issue 1(2019)
- Journal:
- Emergency medicine journal
- Issue:
- Volume 36:Issue 1(2019)
- Issue Display:
- Volume 36, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 36
- Issue:
- 1
- Issue Sort Value:
- 2019-0036-0001-0000
- Page Start:
- e5
- Page End:
- e6
- Publication Date:
- 2019-01-14
- Subjects:
- Emergency medicine -- Periodicals
616.02505 - Journal URLs:
- http://www.bmj.com/archive ↗
https://emj.bmj.com/ ↗ - DOI:
- 10.1136/emermed-2019-999.13 ↗
- Languages:
- English
- ISSNs:
- 1472-0205
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 17899.xml